A Pilot Comparison Study of Vibrating Mesh Versus Standard Jet Nebuliser for Bronchodilator Delivery in COPD

NCT ID: NCT02686086

Last Updated: 2019-07-18

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-02-29

Study Completion Date

2017-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Treatment of chronic obstructive pulmonary disease (COPD) incorporates various modes of inhalation therapy. The response to treatments is dose dependent thus applying the most efficient device to administer the treatment is integral. Evaluation of the efficacy of nebulisation devices in the treatment of COPD is limited. Technological development in recent years has led to new devices that optimize lung deposition and reduce the time needed for treatment.

The aim of this study is to compare the vibrating mesh and jet nebuliser methods of delivering bronchodilator medication to patients hospitalised with an acute exacerbation of COPD, with respect to lung function and efficacy in spontaneously breathing patients.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Treatment of chronic obstructive pulmonary disease (COPD) incorporates various modes of inhalation therapy. The response to treatments is dose dependent thus applying the most efficient device to administer the treatment is integral. Evaluation of the efficacy of nebulisation devices in the treatment of COPD is limited. Technological development in recent years has led to new devices that optimize lung deposition and reduce the time needed for treatment.

The aim of this study is to compare the vibrating mesh and jet nebuliser methods of delivering bronchodilator medication to patients hospitalised with an acute exacerbation of COPD, with respect to lung function and efficacy in spontaneously breathing patients.

Patients admitted to hospital with an exacerbation of COPD and prescribed regular nebulised bronchodilators (combined salbutamol 2.5mg and ipratropium 0.5mg) will be recruited to the study. On one occasion between day 3-7 of admission they will perform pulmonary function testing namely measurement of Forced Expiratory Volume in 1 second(FEV1), Forced Vital Capacity (FVC), Inspiratory Capacity (IC) and cough peak flow. They will also complete the Borg breathlessness score. Measurements will be recorded at baseline (pre-bronchodilator administration) and one hour post-nebulised bronchodilator.

Patients will be randomised to receive their nebulised bronchodilators via the standard hospital jet nebuliser or via a vibrating mesh nebuliser(Aerogen Solo).

Change in lung function and symptom measures between baseline and one-hour post nebulisation will be analysed to look for any significant difference between the two groups

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Chronic Obstructive Pulmonary Disease (COPD)

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Standard hospital jet nebuliser

Patients admitted to hospital with an acute exacerbation of COPD and prescribed nebulised bronchodilator therapy (combined short-acting salbutamol 2.5mg and ipratropium 0.5mg) will receive their prescribed medication via a standard hospital jet nebuliser.

Spirometry, lung volume measurement and symptom score (Borg breathlessness scale) will be recorded pre-nebulisation and at one hour post-nebulisation.

Group Type PLACEBO_COMPARATOR

Standard hospital jet nebuliser

Intervention Type DEVICE

The "standard hospital jet nebuliser" refers to the nebuliser in clinical use currently throughout Beaumont Hospital and used for the administration of nebulised medications

Combined salbutamol 2.5 mg and ipratropium 0.5mg nebule

Intervention Type DRUG

All patients admitted to hospital with an exacerbation of COPD are administered nebulised bronchodilators (salbutamol 2.5mg/ipratropium 0.5mg combination) as standard of care

Vibrating mesh nebuliser

Patients admitted to hospital with an acute exacerbation of COPD and prescribed nebulised bronchodilator therapy (combined short-acting salbutamol 2.5mg and ipratropium 0.5mg) will receive their prescribed medication via a vibrating mesh nebuliser (Aerogen Solo) rather than the standard hospital nebuliser Spirometry, lung volume measurement and symptom score (Borg breathlessness scale) will be recorded pre-nebulisation and at one hour post-nebulisation.

Group Type ACTIVE_COMPARATOR

vibrating mesh nebuliser

Intervention Type DEVICE

The Aerogen Solo vibrating mesh nebuliser is an approved 13 485 class II medical device (CE marked) nebuliser licenced for the delivery of physician-prescribed medications for inhalation which are approved for use with a general purpose nebuliser. It has been shown in previous laboratory and clinical studies to have superior drug delivery to standard jet nebulisers.

Combined salbutamol 2.5 mg and ipratropium 0.5mg nebule

Intervention Type DRUG

All patients admitted to hospital with an exacerbation of COPD are administered nebulised bronchodilators (salbutamol 2.5mg/ipratropium 0.5mg combination) as standard of care

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

vibrating mesh nebuliser

The Aerogen Solo vibrating mesh nebuliser is an approved 13 485 class II medical device (CE marked) nebuliser licenced for the delivery of physician-prescribed medications for inhalation which are approved for use with a general purpose nebuliser. It has been shown in previous laboratory and clinical studies to have superior drug delivery to standard jet nebulisers.

Intervention Type DEVICE

Standard hospital jet nebuliser

The "standard hospital jet nebuliser" refers to the nebuliser in clinical use currently throughout Beaumont Hospital and used for the administration of nebulised medications

Intervention Type DEVICE

Combined salbutamol 2.5 mg and ipratropium 0.5mg nebule

All patients admitted to hospital with an exacerbation of COPD are administered nebulised bronchodilators (salbutamol 2.5mg/ipratropium 0.5mg combination) as standard of care

Intervention Type DRUG

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Hospital Inpatients admitted with an acute exacerbation of COPD
* Age \>40
* COPD Stage 2-4 moderate to severe (FEV1/FVC \<0.70;FEV1\<80%)
* History of physician-diagnosed COPD
* COPD exacerbation between day 2 and day 7 of admission

Exclusion Criteria

* Confusion
* Significant hypoxia/unstable medical condition
* Allergy or contraindication to salbutamol and/or ipratropium
* Pneumonia
* Pregnancy
Minimum Eligible Age

40 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Aerogen

INDUSTRY

Sponsor Role collaborator

Beaumont Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Professor Richard Costello

Professor of Medicine

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Richard W Costello

Role: PRINCIPAL_INVESTIGATOR

RCSI

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Beaumont Hospital

Dublin, , Ireland

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Ireland

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Beaumont

Identifier Type: -

Identifier Source: org_study_id