A Clinical Evaluation of the Oxitone Non-invasive Oximeter

NCT ID: NCT02658045

Last Updated: 2016-01-18

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

40 participants

Study Classification

OBSERVATIONAL

Study Start Date

2016-02-29

Study Completion Date

2016-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The trial shall assess the accuracy of the Oxitone® 1000 in measuring oxygen saturation, by comparing its measurement to reference devices: non-invasive SpO2 and pulse-rate values determined by a pulse oximeter. A total of approximately 40 subjects: 20 healthy and 20 COPD (chronic obstructive pulmonary disease ) patients will be enrolled. These subjects will be enrolled at the medical center pulmonary department and will be recruited from the clinic patient base. The subjects will be represented by male and female adults who optimally cover a range of ethnic backgrounds (skin pigmentation). All testing will be performed in singleton and in a blinded fashion. This study will be conducted with the approval of the medical center ethics committee.

This is a comparison open study with no subject follow-up.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The Oxitone® 1000 oximetry readings are accurate and measure with an acceptable relative absolute difference (RAD) when compared to accepted measurement systems (FDA recognized predicate) the "Reference".

The objectives:

1. To validate the Oxitone® 1000 performance in continuous or spot oximetry monitoring, relative to Reference readings.
2. To aggregate longitudinal clinical data from COPD patients measuring SpO2, pulse rate and activity.
3. To evaluate the main device parameters and characteristics such as sensor placement tolerance, device accuracy, precision, convenience and easy-to-use at stationary supine or seated tests and at mild motions as well.
4. To determine whether the measured data provided from patients (SpO2, pulse rate and movement) is useful in adjusting their treatment protocol.
5. To assess the safety and tolerability (compliance) of the Oxitone® 1000 in continuous oximetry monitoring in order to obtain sufficient clinical trial data in order to define performance criteria of the device system that are acceptable / useful in the medical context for patient populations and other healthy individuals, in which the device is likely to be used.

Overview: The trial shall assess the accuracy of the Oxitone® 1000 in measuring oxygen saturation, by comparing its measurement to reference devices: non-invasive SpO2 and pulse-rate values determined by a pulse oximeter. A total of approximately 40 subjects (20 healthy and 20 COPD patients) will be enrolled. These subjects will be enrolled at the medical center pulmonary department and will be recruited from the clinic patient base. The subjects will be represented by male and female adults who optimally cover a range of ethnic backgrounds (skin pigmentation). All testing will be performed in singleton and in a blinded fashion. This study will be conducted with the approval of the medical center ethics committee.This is a comparison open study with no subject follow-up.

Procedure: All instruments will be checked for functionality and battery operational capacity, prior to subject attachment including the data collection system, i.e. the wireless (B.T.) connectivity to P.C. (synchronized bidirectional two channels).

The "Reference" oximeter device shall be set for averaging mode of 12 seconds. Two sensors will be placed simultaneously on the subjects: A standard SpO2 (reference) will be placed on the subject's index finger and the tested Oxitone® 1000 will be placed on the subject's wrist of the same hand.

Methods:: The investigators are to study approximately 40 subjects, both normal, i.e. comparison group and patients with a variety of pulmonary conditions that effect oxygen saturation. The investigators will compare the oxygen saturation of each subject as measured with Oxitone® 1000 device and with the oxygen saturation as measured with calibrated conventional FDA approved pulse oximeter (predicate). The "Reference". No treatment decision will be made utilizing the results of the tested device.

Trial design:

A. Healthy subjects: Spot-check measurements of 20 healthy volunteers simultaneously tested by using Oxitone oximeter and standard fingertip pulse oximeter at stationary state i.e. at sitting and standing positions up to 6 minutes each.

1\. A 6-minute.walk: oximetry tests of 20 healthy volunteers simultaneously tested using Oxitone oximeter and standard fingertip pulse oximeter in accordance with the industry (Medical) standards of 6-min walk protocol. Measurements are collected and recorded continuously prior to test, during the test and after 6 minutes the test. The distance of the 6-min walk will be recorded (CRF).

B. COPD (Chronic obstructive pulmonary disease) subjects

1. Spot-check measurements up to 20 ambulatory COPD patients. Patients should be referred and admitted to the pulmonary lab for clinical treatment or should be under the rehabilitation procedures. Measurements will be made simultaneously using Oxitone® oximeter and while standard fingertip pulse oximeter stationary state at e.g. supine or dorsal elevated sitting, and while standing (upright) positions up to 6 min each.
2. A 6-min walk oximetry tests of ambulatory COPD patients. Patients should be referred to the pulmonary lab for clinical purposes or should be under the rehabilitation procedures. The measurements are taken using Oxitone® oximeter and standard fingertip pulse oximeter in accordance with the standard protocol. Measurements are taken continuously prior to the test, during the test and 1 minute after the test, at rest. The distance of the 6-min walk will be recorded. Rehabilitation subjects procedures. The measurements are taken using Oxitone® Oximeter and standard fingertip pulse oximeter in accordance with the standard protocol. Measurements are taken continuously prior to the test. The distance of the 6-min walk will be recorded.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

COPD Chronic Lung Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Normal healthy volunteers

Measurement of oxygen saturation simultaneously by standard oximeter and Oxitone oximeter in healthy volunteers during 6 min walking test

Standard Oximeter

Intervention Type DEVICE

Oxygen saturation will be measured by standard oximeter

Oxitone oximeter

Intervention Type DEVICE

Oxygen saturation will be measured by Oxitone oximeter

COPD patients

Measurement of oxygen saturation simultaneously by standard oximeter and Oxitone oximeter in COPD patients during 6 min walking test

Standard Oximeter

Intervention Type DEVICE

Oxygen saturation will be measured by standard oximeter

Oxitone oximeter

Intervention Type DEVICE

Oxygen saturation will be measured by Oxitone oximeter

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Standard Oximeter

Oxygen saturation will be measured by standard oximeter

Intervention Type DEVICE

Oxitone oximeter

Oxygen saturation will be measured by Oxitone oximeter

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Pulmonary sick and healthy male and female volunteers aged 18 years and over (any race or ethnicity).
* Subjects who are willing to give informed consent.
* No precautions are required: this study involves no known additional risk to the subjects.

Exclusion Criteria

* Participants under the age of 18 years
* Significant deformity, degenerative changes or edema of the hand wrist
* Localized infection, ulceration or skin breaks involving the wrist
* Vascular disease or Raynaud's phenomenon affecting the hand
* Participants who are unable to give informed written consent
* Anemia: Hb \< 10.0 g/dl
Minimum Eligible Age

18 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Meir Medical Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Alex 1 Guber, MD

Role: PRINCIPAL_INVESTIGATOR

Meir Medical Center

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Alex - Guber, MD

Role: CONTACT

+972-522-496934

Louis - Shenkman, MD

Role: CONTACT

+972-544-876600

References

Explore related publications, articles, or registry entries linked to this study.

Hornberger C, Matz H, Konecny E, Frankenberger H, Bonk R, Avgerinos J, Benekos K, Valais J, Ikiades A, Gil-Rodriguez J, Wouters P, Meyfroidt G, Ponz L, Gehring H. Design and validation of a pulse oximeter calibrator. Anesth Analg. 2002 Jan;94(1 Suppl):S8-12.

Reference Type BACKGROUND
PMID: 11900044 (View on PubMed)

Mendelson Y. Pulse oximetry: theory and applications for noninvasive monitoring. Clin Chem. 1992 Sep;38(9):1601-7.

Reference Type BACKGROUND
PMID: 1525987 (View on PubMed)

Trivedi NS, Ghouri AF, Shah NK, Lai E, Barker SJ. Effects of motion, ambient light, and hypoperfusion on pulse oximeter function. J Clin Anesth. 1997 May;9(3):179-83. doi: 10.1016/s0952-8180(97)00039-1.

Reference Type BACKGROUND
PMID: 9172022 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

0172-15MMC

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Evaluation of COPD Co-Pilot
NCT02944591 UNKNOWN