Automated Oxygen Titration During Walking in Patients With COPD
NCT ID: NCT04123730
Last Updated: 2021-06-30
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
35 participants
INTERVENTIONAL
2019-10-28
2020-12-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Methods: The study will be conducted as a double blinded randomized crossover trial with two arms. 40 ambulatory patients with COPD and home oxygen treatment will be included from AHH Hospital's catchment area. The patients will conduct two Endurance Shuttle Walk Tests (ESWT) in a crossover design using an O2matic device to deliver a variable oxygen dosage set at an SpO2-target of 90-94% and an O2-flow of 0 - 15 liters/min and using the patients´ usual fixed-dose oxygen delivery, in a randomized order. In both arms O2matic will monitor pulse rate and SpO2 continuously during the test, but only in the automated oxygen titration arm will O2matic adjust oxygen flow. The patient and the physiotherapist supervising the tests will be blinded to the oxygen dose. Primary outcome is the changes in perceived dyspnea intensity using Borg CR10 scale between walking with automated titration compared to fixed-dose treatment. Secondary outcomes are differences in walking time, the average oxygen consumption between automated oxygen titration and fixed-dose treatment and difference in time spent within acceptable SpO2-interval.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Automated Oxygen Titration in Daily Life in Patients With COPD on Home Oxygen
NCT05553847
Automated Oxygen Titration at Home in Patients With COPD on Home Oxygen
NCT05556187
Evaluation of Automatic Oxygen Flow Titration During Walking in Patients With COPD
NCT02150434
Effect of Oxygen in Normoxaemic COPD Patients Who Desaturate During Exercise
NCT00592033
Effects of an Automatic Oxygen Titration System in People With Hypoxemia During Exercise Training
NCT06545851
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The purpose of this study is to evaluate the immediate effect of automated oxygen titration (AOT) compared to usual fixed-dose oxygen treatment (FOT) during exercise in patients with COPD on long-term oxygen treatment.
Method The study will be performed on 40 patients with COPD and on LTOT. An incremental shuttle walk test (ISWT) will be performed to establish the walking speed corresponding to 75% of the estimated peak oxygen consumption. The patients will all use a rollator as walking aid and the oxygen equipment will be placed in the rollator. The patients will after inclusion conduct two Endurance Shuttle Walk Tests (ESWT) with FOT and AOT respectively in a randomized order. One ESWT will be performed using O2matic to deliver a variable oxygen dosage set at an SpO2-target of 90 to 94 % and a O2-flow of 0 - 15 liters/min (AOT). The other ESWT will be performed using the usual fixed-dose oxygen delivery (FOT).
The patients will also conduct two six minutes walking tests (6 MWT) with FOT and AOT in random order in the same way as mentioned above.
Assessments:
Demographic data, including body mass index, and smoking history, will be registered. Use of a rollator, and usual flow of oxygen supplementation will be registered. The score in the CAT- questionnaire (COPD Assessment Test, range of 0-40) will be registered along with the results of the MRC (Medical Research Council, range 1-5).
A lung function test will be performed using Medikro Pro Spirometer. Forced Expiratory Volume in the first second (FEV1) and Forced Vital Capacity (FVC) will be recorded. All lung function measures will be expressed in absolute values and in percent of predicted.
Dyspnea will be registered using Borg Dyspnea Scale CR10 (6). Before, and after completing the 6MWT the patients will be asked to rate their intensity of dyspnea. At the ESWT the patients will rate their intensity of dyspnea before and after completing the test and every minute during the test.
Hand grip strength will be measured using static hand squeeze around a dynamometer.
Walking tests:
Shuttle Walk Test will be performed using the Incremental Shuttle Walk Test (ISWT) followed by the Endurance Shuttle Walk Test (ESWT) on two different days. ISWT is initially conducted once for familiarization followed by a second test. The patients will be given a rest of 20 minutes between tests and the best result is recorded. The results of ISWT will be used to calculate the walking speed in the ESWT, which will be set at 75% of max and not 85% of max as the intension is to keep the patients walking for more than just 1-3 minutes. The patient is in both tests required to walk around two cones set 9 meters apart (so the final track is 10 meters). In the ESWT the patients are asked to walk as long as possible until they are unable to continue. The time walked in the ESWT will be registered.
The six-minute walking test (6 MWT), assesses the distance walked in metres over six minutes as a sub-maximal test of aerobic capacity/endurance. It requires the patient to walk between cones set 30 meters apart(8).
Walking limitation will be noted. The patients will be asked to report the primary limitation for not being able to walk longer: dyspnea, leg fatigue, pain, discomfort, anxiety or "other reasons".
Oxygen consumption and oxygen saturation (SpO2) will be registered using O2matic, a device which adjusts the oxygen flow to maintain the saturation within a target interval. O2matic is a device, which based on continuous, non-invasive measurement of SpO2 adjusts oxygen flow to the patient within a defined target interval. SpO2-target can be set individually, but in this study will be fixed at 90 to 94 %. If SpO2 falls below 90 % oxygen flow will increase, and if SpO2 increases above 94 % oxygen flow will decrease. The adjustments are done every second based on average SpO2 for the last 15 seconds. In case of low SpO2 (below target or below 85 %), low pulse rate (\<45) or high pulse rate (user defined) an alarm will be visible and audible.
Statistical considerations and strength calculation:
The primary outcome is change in the BORG CR10 dyspnea scale. The minimal clinical important difference (MCID) is 1 unit (9) and standard deviation expected to be 2.0. Based on alfa of 0,05 and a power of 80 % a sample of 33 patients is needed to examine if AOT results in improvement in time walked during the ESWT. Due to possible dropout 40 patients will be included in the study. Categorical variables are compared using Chi-Square or Fisher's exact test, as appropriate. Continuous variables are examined for normality and analyzed with either unpaired t-test (in case of normality) or Wilcoxon-Mann-Whitney test (in case of non-normality). The Statistical Package SPSS ver. 22 will be used for all statistical analyses.
The study will take place at Hvidovre Hospital from October 2019 and until all 40 patients are included. Linette Marie Kofod is the principal investigator. The study will be conducted as an interdisciplinary collaboration between the Pulmonary Section and the Department of Physiotherapy, Amager and Hvidovre University Hospital, which have approved the study.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Fixed dose oxygen
O2Matic deliver the usual fixed-dose oxygen treatment during walking.
Fixed-dose compared to variable oxygen flow supplementation during walking
At day 1 the patients will perform Walk A and Walk B in a random order:
Walk A: The patients will perform a Endurance Shuttle Walk Tests (ESWT) with the fixed-dose (FOT). O2matic will monitor pulse rate and saturation continuously during the test.
Walk B: The patients will perform a Endurance Shuttle Walk Tests (ESWT) with a variable oxygen flow (AOT) depending on the saturation. O2matic will monitor pulse rate and saturation continuously during the test, and adjust oxygen flow depending on the saturation.
At day 2 the patients will perform two 6 minutes walking (MWT) test in random order:
Walk C: A 6 MWT with FOT Walk D; A 6 MWT with AOT
Automated oxygen titration
O2Matic deliver a variable oxygen dosage set at an SpO2-target of 90 to 94 % and a O2-flow of 0 - 15 liters/min during walking.
Fixed-dose compared to variable oxygen flow supplementation during walking
At day 1 the patients will perform Walk A and Walk B in a random order:
Walk A: The patients will perform a Endurance Shuttle Walk Tests (ESWT) with the fixed-dose (FOT). O2matic will monitor pulse rate and saturation continuously during the test.
Walk B: The patients will perform a Endurance Shuttle Walk Tests (ESWT) with a variable oxygen flow (AOT) depending on the saturation. O2matic will monitor pulse rate and saturation continuously during the test, and adjust oxygen flow depending on the saturation.
At day 2 the patients will perform two 6 minutes walking (MWT) test in random order:
Walk C: A 6 MWT with FOT Walk D; A 6 MWT with AOT
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Fixed-dose compared to variable oxygen flow supplementation during walking
At day 1 the patients will perform Walk A and Walk B in a random order:
Walk A: The patients will perform a Endurance Shuttle Walk Tests (ESWT) with the fixed-dose (FOT). O2matic will monitor pulse rate and saturation continuously during the test.
Walk B: The patients will perform a Endurance Shuttle Walk Tests (ESWT) with a variable oxygen flow (AOT) depending on the saturation. O2matic will monitor pulse rate and saturation continuously during the test, and adjust oxygen flow depending on the saturation.
At day 2 the patients will perform two 6 minutes walking (MWT) test in random order:
Walk C: A 6 MWT with FOT Walk D; A 6 MWT with AOT
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Hypoxemic at rest (SpO2 ≤ 90 %) and fulfilment of criteria for LTOT
* Able to walk at least 70 meters
* Cognitively able to participate in the study and willing to give informed consent
Exclusion Criteria
* Unstable heart condition or stenotic aortic valve disease
* A physical condition including paralysis, lower extremity pain, or back problem limiting exercise performance
* Exacerbation in COPD treated with either antibiotics or prednisolone within the last 3 weeks
30 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Region Örebro County
OTHER
Aalborg University Hospital
OTHER
Danmarks Lungeforening
OTHER
Hvidovre University Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Linette Marie Kofod
Physiotherapist
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Linette Marie Kofod, PT
Role: PRINCIPAL_INVESTIGATOR
Hvidovre University Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Copenhagen University Hospital, Hvidovre
Hvidovre, , Denmark
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
O'Driscoll BR, Howard LS, Earis J, Mak V; British Thoracic Society Emergency Oxygen Guideline Group; BTS Emergency Oxygen Guideline Development Group. BTS guideline for oxygen use in adults in healthcare and emergency settings. Thorax. 2017 Jun;72(Suppl 1):ii1-ii90. doi: 10.1136/thoraxjnl-2016-209729. No abstract available.
Hansen EF, Hove JD, Bech CS, Jensen JS, Kallemose T, Vestbo J. Automated oxygen control with O2matic(R) during admission with exacerbation of COPD. Int J Chron Obstruct Pulmon Dis. 2018 Dec 14;13:3997-4003. doi: 10.2147/COPD.S183762. eCollection 2018.