Detecting a Volume Deficit During Spontaneous Breathing

NCT ID: NCT02549482

Last Updated: 2015-09-15

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

13 participants

Study Classification

INTERVENTIONAL

Study Start Date

2011-08-31

Study Completion Date

2011-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

13 healthy volunteers (4 females) were tilted 45° head-up while breathing through a facemask fitted with an inspiratory and expiratory resistor. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation and pulse contour analysis determined stroke volume and thereby cardiac output in order to detect a central volume deficit.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Thirteen healthy volunteers (4 women) at an age of 25 years (range 18-36) were recruited through www.forsøgsperson.dk.

The volunteers were placed on a tilt table and provided with a facemask with an opening of 30-33 mm. A Hook ring was fitted with an inspiratory resistor, an expiratory resistor, a combination of the two resistors, or with no resistance and each resistor provides a 7.5 cmH2O threshold resistance. Each resistor was applied for two minutes with variables obtained in the last minute. The table was then tilted 45° head-up to accumulating blood in the legs and therefore a reduction in the central blood volume. Conversely, 20° head-down tilt was used to expand the central blood volume. For each volunteer measurements with the four respiratory interventions was randomized, whereas the tilt table position was in fixed order: supine, head-up tilt, and head-down tilt.

Three-lead ECG recorded heart rate. A 20 G arterial catheter was placed in the brachial artery of the non-dominant arm and connected to a transducer for reading of blood pressure and stroke volume variation (Vigileo-Flotrac™, version 1.07, Edwards Lifesciences, Nyon, Switzerland). Also SV and CO variation and the arterial pressure curve were recorded for subsequent determination of arterial pressure variations. Additionally, a catheter was placed via a brachial vein to the superior caval vein for recording of central venous pressure and SvO2. While the subjects were breathing spontaneously, the respiratory rate was measured by capnography and peripheral oxygen saturation by fingerprobe.

Variation in the arterial pulse pressure (PPV) was 100 x ((PPmax - PPmin) / ((PPmax + PPmin)/2)), where PPmax and PPmin is the maximal and minimal difference between systolic and diastolic pressure during the respiratory cycle, respectively. By the same formula systolic pressure variation (SPV) was calculated.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hypovolemia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Blinding Strategy

NONE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Respiratory resistor

The volunteers are breathing through the four respiratory resistors (inspiratory, expiratory, combined in- and expiratory and no resistor) in order to increase the intrathoracic pressure svings

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* healthy volunteers

Exclusion Criteria

* pregnancy
* lactating
* any regular or acute use of medicine
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Rigshospitalet, Denmark

OTHER

Sponsor Role collaborator

Aalborg University Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Michael Dahl

MD

Responsibility Role PRINCIPAL_INVESTIGATOR

References

Explore related publications, articles, or registry entries linked to this study.

Dahl M, Hayes C, Steen Rasmussen B, Larsson A, Secher NH. Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing? BMC Anesthesiol. 2016 Aug 11;16(1):58. doi: 10.1186/s12871-016-0224-z.

Reference Type DERIVED
PMID: 27515038 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

H-4-2010-110-SPV

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

The PneumoRator Study
NCT07293299 RECRUITING