Technical Performance of a New Cardiac Technology "IQ-SPECT" Applied to SCINTI-CT Myocardial Imaging With 99mTc-Sestamibi in Coronary Patients
NCT02524600 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 103
Last updated 2015-08-17
Summary
Cardiological examination is one of the major directions in nuclear medicine for detection of myocardial ischemia in patients with suspected coronary artery disease. In Caen, they constitute 20% of the activity of nuclear medicine. It is evaluating a new versatile innovative technology (IQ-SPECT) for performing rapid nuclear cardiological examinations (4 minutes) and quality on a SCINTI-CT camera for correcting the mitigation. This technical solution IQ-SPECT was made available to the nuclear medicine department in August 2011. To date, apart from the work on heart ghosts and one publication in abstract form in 2009, no other study have been published.
The goal of the study is to study the technical performance of the innovative technology IQ-SPECT during a SCINTI-CT imaging in patients suspected of coronary disease .
Conditions
- Coronary Artery Disease
Interventions
- DEVICE
-
myocardial IQ-SPECT imaging applied to scintigraphic imaging
- DEVICE
-
scintigraphic imaging
Sponsors & Collaborators
-
University Hospital, Caen
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-01-31
- Primary Completion
- 2012-06-30
Countries
- France
Study Locations
Related Clinical Trials
-
Rubidium-82 PET and Tc-99m-MIBI SPET: A Head to Head Comparison
NCT01379677 · Status: COMPLETED · Phase: PHASE3
- Coronary Artery Disease
-
Computed Tomography as the First-Choice Diagnostics in High Pre-Test Probability of Coronary Artery Disease
NCT02591992 · Status: UNKNOWN · Phase: NA
- Coronary Artery Disease
-
Efficacy and Saftey Study of 99mTc-ECDG in the Evaluation of Coronary Artery Disease (CAD)
NCT01899833 · Status: NOT_YET_RECRUITING · Phase: PHASE2
- Coronary Artery Disease
-
Image Quality and Radiation Dose Associated With Cardiac Scans in Modern CT Scanners
NCT05245149 · Status: UNKNOWN
- Coronary Artery Disease
-
Computed Tomography Coronary Angiography for the Prevention of Myocardial Infarction (The SCOT-HEART 2 Trial)
NCT03920176 · Status: ACTIVE_NOT_RECRUITING · Phase: NA
- Cardiovascular Diseases
More Related Trials
-
The CArdiac Imaging RegistrY Study
NCT04936867 ·Status: COMPLETED
-
Usefulness of Coronary CT Angiography in Patients With Inconclusive Stress Test Results
NCT00465335 ·Status: COMPLETED
-
Contrast Enhancement on Coronary Computed Tomographic Angiography
NCT02462044 ·Status: COMPLETED ·Phase: PHASE4
-
Multi-modality Imaging in Acute Myocardial Infarction
NCT02926755 ·Status: COMPLETED ·Phase: NA
-
Comparison of Cardiac Computed Tomographic Angiography (CTA) to Tc-99m Single Photon Emission Computed Tomography (SPECT)
NCT00449943 ·Status: COMPLETED ·Phase: NA
-
CORE-COMPARE Pilot Study
NCT06170541 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Coronary Artery Calcification Using Gated Stationary Chest Tomosynthesis
NCT03169062 ·Status: COMPLETED ·Phase: NA
-
Monitoring and Rehabilitation for ICIACI Rehabilitation:A Cohort Study
NCT07278817 ·Status: NOT_YET_RECRUITING
-
Comparing a Diagnostic and Treatment Strategy of Upfront CTCA With SOC in Patients With Chest Pain and Suspected CAD
NCT05344612 ·Status: RECRUITING ·Phase: NA
-
Accuracy of Half of the Usual Radiotracer Dose in SPECT
NCT01412827 ·Status: COMPLETED ·Phase: NA
-
Xenetix® 350: Comparative Assessment of Image Quality for Coronary CT Angiography
NCT01255722 ·Status: COMPLETED ·Phase: PHASE4
-
The EASE-IT CT Registry
NCT05750173 ·Status: RECRUITING
-
Characterization of RadiOlabeled Tracer Uptake Pattern in Noninfected Transcatheter Aortic Valves.
NCT03683355 ·Status: ACTIVE_NOT_RECRUITING
-
Vascular Toxicities of Immune ChecKpoint Inhibitors : From Bed to Benchside
NCT06020651 ·Status: UNKNOWN ·Phase: NA
-
Iodine Content for Diagnostic AccuRacy and Patient Comfort For Individuals Undergoing Cardiac Computed Tomography (CT) Scanning
NCT01052441 ·Status: COMPLETED
-
Detection of Coronary Artery Calcification: Comparison of Volumetric and Electron Beam Computed Tomography
NCT00001836 ·Status: COMPLETED
-
Coronary Computed Tomography Versus Invasive Angiography for Non-ST Elevation Acute Coronary Syndrome
NCT06101862 ·Status: RECRUITING ·Phase: NA
-
Cardiac Computed Tomography In the Management of Patients With indeterminAte or inConclusive Stress Tests
NCT00541203 ·Status: COMPLETED
-
Comparison of Isovue 370 vs. Standard Protocol in Coronary Computed Tomographic Angiography (CTA)
NCT02171247 ·Status: COMPLETED ·Phase: PHASE3
-
High Definition CT Coronary Angiography Accuracy Trial
NCT01946737 ·Status: COMPLETED ·Phase: NA
-
Iodixanol in Multidetector-Row Computed Tomography-Coronary Angiography (MDCT-CA)
NCT00209404 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of the Evaluation of CAD by CT AngioScan and Coronary Angiogram
NCT01779986 ·Status: UNKNOWN
-
Computed Tomographic Angiography or Conventional Coronary Angiography in Clinical Decision Making
NCT00566059 ·Status: COMPLETED
-
Clinical Impact of Cardiac Photon Counting CT
NCT05240807 ·Status: RECRUITING ·Phase: NA
-
Atherosclerosis in Chemotherapy-related Cardiotoxicity
NCT05118178 ·Status: COMPLETED