Accuracy of Half of the Usual Radiotracer Dose in SPECT
NCT01412827 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 18
Last updated 2016-02-24
Summary
There has been a shortage of nuclear isotopes, not only in Canada but around the world. New, more sensitive SPECT cameras can obtain better images in shorter scan times. These cameras have also shown the ability to use a smaller dose of radioisotope to obtain the images. New software has been tested on the standard camera, the GE Infinia-Hawkeye SPECT/CT. The Diagnostic Imaging Department of The University of Ottawa Heart Institute has also acquired a new camera, the Discovery NM530c CZT and has been doing heart scans in shorter times. The investigators will now be looking at the quality of images using less isotope during SPECT myocardial perfusion imaging for diagnostic and prognostic purposes.
Conditions
- Coronary Artery Disease
Interventions
- RADIATION
-
1/2 dose of 99mTc OR 201Tl tracers
Rest: Imaging will occur 30 to 60 minutes after injection of tracer. Stress: All patients will undergo a symptom-limited Bruce protocol treadmill exercise test. At peak stress, the radiotracer will be injected intravenously, and exercise will continue for an additional 60 s. The patients who are unable to achieve the targeted heart rate or exercise will be stressed pharmacologically. Dipyridamole (0.142 mg/kg/min) will be infused intravenously for 5 minutes, and 99mTc radiotracer will be injected at 2 min after infusion completion (7 min into the study). Aminophylline (100-200 mg) will be given intravenously 2 min after injection of the radiotracer.
Sponsors & Collaborators
-
Ottawa Heart Institute Research Corporation
lead OTHER
Principal Investigators
-
Renée Hessian, MD · Ottawa Heart Institute Research Corporation
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2010-04-30
- Primary Completion
- 2013-03-31
- Completion
- 2014-09-30
Countries
- Canada
Study Locations
Related Clinical Trials
-
Comparison of Cardiac Computed Tomographic Angiography (CTA) to Tc-99m Single Photon Emission Computed Tomography (SPECT)
NCT00449943 · Status: COMPLETED · Phase: NA
- Coronary Artery Disease
-
Rubidium-82 PET and Tc-99m-MIBI SPET: A Head to Head Comparison
NCT01379677 · Status: COMPLETED · Phase: PHASE3
- Coronary Artery Disease
-
Optimization of SPECT Imaging
NCT01519973 · Status: TERMINATED · Phase: NA
- Coronary Artery Disease
-
Computed Tomography Coronary Angiography for the Prevention of Myocardial Infarction (The SCOT-HEART 2 Trial)
NCT03920176 · Status: ACTIVE_NOT_RECRUITING · Phase: NA
- Cardiovascular Diseases
-
IMAGE-HF Project I-C: Computed Tomographic Coronary Angiography for Heart Failure Patients
NCT01283659 · Status: COMPLETED · Phase: NA
- Heart Failure
More Related Trials
-
Comparison of Isovue 370 vs. Standard Protocol in Coronary Computed Tomographic Angiography (CTA)
NCT02171247 ·Status: COMPLETED ·Phase: PHASE3
-
Ontario Multidetector Computed Tomographic (MDCT) Coronary Angiography Study (OMCAS)
NCT00371891 ·Status: COMPLETED ·Phase: PHASE4
-
High Definition CT Coronary Angiography Accuracy Trial
NCT01946737 ·Status: COMPLETED ·Phase: NA
-
Technical Performance of a New Cardiac Technology "IQ-SPECT" Applied to SCINTI-CT Myocardial Imaging With 99mTc-Sestamibi in Coronary Patients
NCT02524600 ·Status: COMPLETED ·Phase: NA
-
Comparing a Diagnostic and Treatment Strategy of Upfront CTCA With SOC in Patients With Chest Pain and Suspected CAD
NCT05344612 ·Status: RECRUITING ·Phase: NA
-
CCTA to Optimize Diagnostic Yield of Invasive Angiography With AI
NCT06648239 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Usefulness of Coronary CT Angiography in Patients With Inconclusive Stress Test Results
NCT00465335 ·Status: COMPLETED
-
Multi-modality Imaging in Acute Myocardial Infarction
NCT02926755 ·Status: COMPLETED ·Phase: NA
-
Assessment of Patients With Suspected Coronary Artery Disease (CAD): What is the Best Initial Imaging Strategy?
NCT01668290 ·Status: COMPLETED
-
The Role Of Noninvasive 320-Row Multidetector Computer Tomography
NCT01405690 ·Status: COMPLETED
-
CCTA to Optimize the Diagnostic Yield of Invasive Angiography
NCT03554057 ·Status: COMPLETED
-
Computed Tomography as the First-Choice Diagnostics in High Pre-Test Probability of Coronary Artery Disease
NCT02591992 ·Status: UNKNOWN ·Phase: NA
-
Image Quality and Radiation Dose Associated With Cardiac Scans in Modern CT Scanners
NCT05245149 ·Status: UNKNOWN
-
Clinical Impact of Cardiac Photon Counting CT
NCT05240807 ·Status: RECRUITING ·Phase: NA
-
Influence of Iodinated Contrast Volume Injected During Coronarography on Contrast Nephropathy.
NCT03918824 ·Status: COMPLETED
-
Characterization of RadiOlabeled Tracer Uptake Pattern in Noninfected Transcatheter Aortic Valves.
NCT03683355 ·Status: ACTIVE_NOT_RECRUITING
-
Coronary Computed Tomography Versus Invasive Angiography for Non-ST Elevation Acute Coronary Syndrome
NCT06101862 ·Status: RECRUITING ·Phase: NA
-
Iodixanol in Multidetector-Row Computed Tomography-Coronary Angiography (MDCT-CA)
NCT00209404 ·Status: COMPLETED ·Phase: PHASE4
-
Detection of Coronary Artery Calcification: Comparison of Volumetric and Electron Beam Computed Tomography
NCT00001836 ·Status: COMPLETED
-
Iodine Content for Diagnostic AccuRacy and Patient Comfort For Individuals Undergoing Cardiac Computed Tomography (CT) Scanning
NCT01052441 ·Status: COMPLETED
-
Efficacy and Saftey Study of 99mTc-ECDG in the Evaluation of Coronary Artery Disease (CAD)
NCT01899833 ·Status: NOT_YET_RECRUITING ·Phase: PHASE2
-
Xenetix® 350: Comparative Assessment of Image Quality for Coronary CT Angiography
NCT01255722 ·Status: COMPLETED ·Phase: PHASE4
-
The CArdiac Imaging RegistrY Study
NCT04936867 ·Status: COMPLETED
-
Cardiac Computed Tomography In the Management of Patients With indeterminAte or inConclusive Stress Tests
NCT00541203 ·Status: COMPLETED
-
Extensive CArdioVAscular Characterization and Follow-up of Patients Receiving Immune Checkpoint Inhibitors
NCT05699915 ·Status: TERMINATED ·Phase: NA