Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
84 participants
INTERVENTIONAL
2015-06-30
2017-05-05
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
New technology has been developed and is widely used. Among this technology, we have the VERION Image Guided System. This system encompasses a reference unit that takes a picture of the eye with the patient in the sitting position creating image of the patient's eye, capturing scleral vessels, limbus and iris features. It measures keratometry as well as the corneal diameter (limbus) and pupil size. The information captured is transferred automatically to its planner where IOL power calculation and astigmatism correction calculation are completed. Additionally, intraoperative wavefront aberrometry has been used in the last couple of years with increase success.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Limbal Relaxing Incision Versus Toric Intraocular Lens for Corneal Astigmatism During Cataract Surgery.
NCT02067429
Optimizing the Assessment of Refractive Outcomes After Cataract Surgery
NCT02842151
Comparison of Pre-operative Measurements With Intraoperative Aberrometry in Predicting Correction for Low Toric Lens Correction in Cataract Surgery
NCT04247152
Comparison of Toric IOL Implantation and Opposite Clear Corneal Incision During Cataract Surgery to Correct Corneal Astigmatism
NCT01763151
Subjective and Objective Refraction in Pseudophakic Patients
NCT04319497
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Currently available treatments include corneal or limbal incisions, the use of toric intraocular lenses (IOLs) or LASIK. Limbal relaxing incisions (LRIs) are the most commonly used manual method Traditionally, LRIs have been made manually (with a surgical knife). With the introduction of femtosecond laser to assist during cataract surgery, a new alternative is available for creating corneal incisions. The stability of the LRIs and visual outcomes using toric IOLs have been shown.
Regardless of the treatment of choice to correct the astigmatism at time of cataract extraction, a treatment plan has to be calculated preoperatively. This planning include: keratometry measurements and the use of a calculator to estimate the treatment and orientation of IOL and placement of the LRIs.
Keratometry can be measured using a variety of devices including manual keratometers (i.e. Javal-Shiotz), automated keratometers, corneal topography, and optical biometry ( IOL master and Lenstar).
Once keratometry to be used has been selected, if the treatment of choice are LRIs, a calculator is used to determine the location and size of the LRI. Many nomograms have been developed; the choice of nomogram is the surgeon's prefer one, usually based on prior experience, and their preferred knife. LRIs calculators are available on line. Nomograms specify the location, length, size, and number of incisions based on the patient's age, the type of astigmatism, and the amount of astigmatism correction needed.
If a toric IOL has been chosen then planning the appropriate orientation of the toric IOL is accomplished by using online calculators. The calculator selects the optimal toric power and location based on the keratometry and the surgically induced astigmatism (SIA) values entered by the surgeon.
Intraoperatively, marking the eye and placing the incisions or aligning the toric IOL in the right axis are key steps for the success of astigmatism correction. Marking of the eye can be done using a variety of instruments using ink and it is routinely done with the patient in the upright position to avoid cyclorotation. Once patient is on the table in supine position, axis should be checked once again. Additional suggested methods to mark the eye include taking pictures preoperatively to identify anatomical landmarks similar to iris registration in refractive surgery. The use of iris registration during LASIK was introduced in 2008. Several publications have shown that patients undergoing wavefront-guided LASIK with iris recognition achieved better visual and refractive outcomes compared to conventional LASIK.
Recently, Alcon introduced VERION Image Guided System: Digital Surgical Planning and Positioning Tools. This system encompasses a reference unit that takes a picture of the eye with the patient in the sitting position creating a high-resolution digital image of the patient's eye, capturing scleral vessels, limbus and iris features. It measures keratometry as well as the corneal diameter (limbus) and pupil size. The information captured is then transferred automatically to the planner where additional information including target refraction, manifest refraction, axial length, anterior chamber depth, and lens thickness is entered for IOL power calculation and astigmatism correction planning. Astigmatism correction options include corneal incisions, toric IOL and a combination of both. Intraoperatively, The VERION Digital Marker displays patient information and images from the VERION Reference Unit. Additionally it positions all incision locations and assists with lens alignment in real time while accounting for the variable impact of cyclorotation and patient eye movement. In the OR, it displays a reticle that helps to align the IOL to the axis according the surgical plan. It also helps to position manual LRIs.
Intraoperative wavefront aberrometry has been used in the last couple of years to confirm spherical and toric power as well as lens position. The Optiwave Refractive Analysis (ORA) system can refract the eye in phakic, aphakic, and pseudophakic states at any time during cataract surgery and assists in IOL power selection and recommendations for toric IOL positioning before and after implantation as well as LRIs confirming the surgery plan calculated preoperatively. Furthermore, VerifEye, an ORA hardware upgrade, provides continuous assessment of the patient's eye allowing for more precise measurements; therefore, more accurate results and improved refractive outcomes and VerifEye +, the latest upgrade that provides streaming information on the refractive status and correct IOL positioning through the right ocular of the surgical microscope. This enables the surgeon to visualize all the information without having to look up at the monitor screen during the surgical procedure.
This new technology is an alternative to plan and treat astigmatism at the time of cataract surgery. It could make this treatment easier for less experience surgeons by facilitating the calculations and making the identification of the correct axis easier by reducing the need for manual marks.
The main objective of this study is to evaluate spherical and astigmatism outcomes post routine cataract surgery when the complete VERION Image Guided System packet + ORA System with VerifEye or VerifEye + are used in the treatment of pre-existing astigmatism using toric intraocular lens (IOL) or corneal incisions compared to the surgeon's standard of care.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Conventional
Surgeon's standard of care prior to getting VERION. Spherical power will be selected using the surgeon's preferred formula (Haigis, Holladay 2, Holladay, or other) and biometry method (IOL Master, Lenstar). Astigmatism correction will be planned using the surgeon's preferred keratometry method and calculator/nomogram to determine toric power and corneal incisions (i.e. Alcon toric calculator, Holladay toric calculator, Abbott Medical Optics (AMO) LRI calculator, etc). At time of surgery, axis of placement will be marked using blue ink marks. Corneal incisions will be made manually.
Conventional
Routine cataract surgery by phacoemulsification before laser-assisted cataract surgery.
Refractive Cataract Suite (Verion + ORA)
Digital Surgical Planning and Positioning Tools + ORA System with VerifEye or VerifEye +. Spherical power of the IOL will be selected using the Verion Planner with the surgeon's preferred formula with an optimized A-constant (Haigis, Holladay 2, Holladay, or other). Both toric lenses and corneal incisions will be calculated with the Verion Planner using the Verion Reference Unit keratometry and white to white measurements, and Lenstar biometry. The VERION Digital Markers L and M will be used for axis of placement and confirmed using ORA System with VerifEye or VerifEye +.
Refractive Cataract Suite (Verion + ORA)
Laser-assisted cataract surgery with the digital surgical planning and positioning tools, and intraoperative aberrometry.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Conventional
Routine cataract surgery by phacoemulsification before laser-assisted cataract surgery.
Refractive Cataract Suite (Verion + ORA)
Laser-assisted cataract surgery with the digital surgical planning and positioning tools, and intraoperative aberrometry.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Willing and able to provide written informed consent for participation in the study
* Willing and able to comply with scheduled visits and other study procedures.
Exclusion Criteria
* Uncontrolled diabetes.
* Use of any systemic or topical drug known to interfere with visual performance.
* Contact lens use during the active treatment portion of the trial.
* Any concurrent infectious/non infectious conjunctivitis, keratitis or uveitis.
* Pseudoexfoliation syndrome or any other condition that has the potential to weaken the zonules
* Previous refractive surgery.
* Any clinically significant, serious or severe medical or psychiatric condition that may increase the risk associated with study participation or study device implantation or may interfere with the interpretation of study results.
* Participation in (or current participation) any investigational drug or device trial within the previous 30 days prior to the start date of this trial.
* Intraocular conventional surgery within the past three months or intraocular laser surgery within one month in the operated eye.
50 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Science in Vision
OTHER
Carolina Eyecare Physicians, LLC
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Kerry D Solomon, MD
Role: PRINCIPAL_INVESTIGATOR
Carolina Eyecare Physicians, LLC
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Carolina Eyecare Physicians, LLC
Mt. Pleasant, South Carolina, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CEP 2014-003
Identifier Type: -
Identifier Source: org_study_id
More Related Trials