Endotracheal Tube Audible Leak Test

NCT ID: NCT02461017

Last Updated: 2017-07-02

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

86 participants

Study Classification

OBSERVATIONAL

Study Start Date

2015-12-07

Study Completion Date

2017-02-21

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The endotracheal tube (ETT) leak test (LT), or audible leak test is a widely performed assessment to verify appropriate tube size in neonates, infants and children. However, many factors are known to influence the audible leak test. Even though the test is widely performed, the accuracy has not been evaluated.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The endotracheal tube (ETT) leak test (LT), or audible leak when the peak airway pressures reach 15-30 cmH2O, is a commonly performed assessment to confirm that an endotracheal tube size is appropriate for a child in order to minimize the risk of airway injury and adverse events after removal of ETT. Many factors are known to affect the results of the leak test and variation in results among experienced anesthesiologists may be as great as 38%, but the accuracy of the audible leak test by directly observing the presence of a leak around the ETT has not been evaluated. This study will attempt to use direct visualization of the air leak to correlate to and assess the accuracy of the audible air leak test.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Anesthesia Intubation Complication Mechanical Ventilation Complication

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Endotracheal Leak

Assess for Audible Endotracheal Leak; Assess for Endotracheal Leak with direct visualization under rigid bronchoscope

Assess for Audible Endotracheal Leak

Intervention Type OTHER

In supine position, the head will be positioned in neutral position. With fresh gas flow at 2-5L/min, and pop off valve in the anesthesia machine closed and pressure in the inspiratory circuit is slowly increased until an audible leak is heard at the mouth. That pressure will be recorded.

Assess for Endotracheal Leak with direct visualization under rigid bronchoscope

Intervention Type OTHER

In the same patient position, a flexible nasal laryngoscope will be inserted and positioned superior to the laryngeal inlet by the surgeon. With fresh gas flow at 2-5L/min, and pop off valve in the anesthesia machine closed, the pressure in the inspiratory circuit will be increased slowly until a leak around the TT will be visualized by inspecting the supraglottic area for bubbles or air movement around the TT. The peak pressure at which leak is observed physically will be recorded. This is the end of the study.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Assess for Audible Endotracheal Leak

In supine position, the head will be positioned in neutral position. With fresh gas flow at 2-5L/min, and pop off valve in the anesthesia machine closed and pressure in the inspiratory circuit is slowly increased until an audible leak is heard at the mouth. That pressure will be recorded.

Intervention Type OTHER

Assess for Endotracheal Leak with direct visualization under rigid bronchoscope

In the same patient position, a flexible nasal laryngoscope will be inserted and positioned superior to the laryngeal inlet by the surgeon. With fresh gas flow at 2-5L/min, and pop off valve in the anesthesia machine closed, the pressure in the inspiratory circuit will be increased slowly until a leak around the TT will be visualized by inspecting the supraglottic area for bubbles or air movement around the TT. The peak pressure at which leak is observed physically will be recorded. This is the end of the study.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Children aged between 1 month (post-natal) and 8 years scheduled for ENT surgery requiring general anesthesia with an endotracheal tube.

Exclusion Criteria

* Known history of subglottic stenosis
* Known history of recurrent croup
* Known history of endolaryngeal or subglottic lesions
* Parents refusal of participation in study
Minimum Eligible Age

1 Month

Maximum Eligible Age

8 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Mississippi Medical Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Madhankumar Sathyamoorthy

Assistant Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Madhankumar Sathyamoorthy, MBBS, MS

Role: PRINCIPAL_INVESTIGATOR

Univeristy of Mississippi Medical Center

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Mississippi Medical Center

Jackson, Mississippi, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Suominen P, Taivainen T, Tuominen N, Voipio V, Wirtavuori K, Hiller A, Korpela R, Karjalainen T, Meretoja O. Optimally fitted tracheal tubes decrease the probability of postextubation adverse events in children undergoing general anesthesia. Paediatr Anaesth. 2006 Jun;16(6):641-7. doi: 10.1111/j.1460-9592.2005.01832.x.

Reference Type BACKGROUND
PMID: 16719880 (View on PubMed)

Finholt DA, Henry DB, Raphaely RC. Factors affecting leak around tracheal tubes in children. Can Anaesth Soc J. 1985 Jul;32(4):326-9. doi: 10.1007/BF03011335.

Reference Type BACKGROUND
PMID: 4027762 (View on PubMed)

Schwartz RE, Stayer SA, Pasquariello CA. Tracheal tube leak test--is there inter-observer agreement? Can J Anaesth. 1993 Nov;40(11):1049-52. doi: 10.1007/BF03009476.

Reference Type BACKGROUND
PMID: 8269566 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2015-0164

Identifier Type: -

Identifier Source: org_study_id

More Related Trials