Prospective Clinical Evaluation of the Taperguard Endotracheal Tube
NCT ID: NCT02450929
Last Updated: 2018-08-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
102 participants
OBSERVATIONAL
2012-12-12
2016-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The study will include data from all adult patients who had surgery at OHSU between June 1, 2011 and February 15, 2014. We anticipate that we will enroll approximately 40,000 subjects (at least 22,000 in the pre-intervention group and at least 16,000 in the post-intervention group). Data will be gathered from the OHSU electronic medical record system (Centricity and Epic).
6\. A multiple logistic regression analysis will be employed to determine the rates of pneumonia between the use of a standard barrel-cuff designed ETT and the Taperguard ETT for the defined group of surgical patients. The regression analysis would be adjusted for confounding variables including ASA status, age, use of paralytic, RSI with cricoid pressure, weight, pre-existing lung disease.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Tracheal Cuff Pressure and Postoperative Complications: A Prospective Observational Study.
NCT07264179
Removing Fluid Above Breathing Tubes in the Operating Room
NCT01110109
Adequate Additional Bronchial Cuff Volume to Achieve Blood-tight Seal After Air-tight Seal in Double Lumen Tube
NCT01979640
Effectiveness of Oscillation on Postoperative Pulmonary Complications After Elective Postcardiac Surgery
NCT06902220
Effect of the Minimum Bronchial Cuff Volume of Left-sided Double-lumen Endotracheal Tube for One-lung Ventilation on the Change of the Bronchial Cuff Pressure During Lateral Positioning in Thoracic Surgery
NCT05222568
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The Taperguard tube⢠(Covidien, Boulder, CO) is designed to prevent micro aspiration around channels that otherwise form with a barrel-shaped cuff. Laboratory evidence suggests less passage of fluid around the tube then conventional barrel-shaped cuffs (Batchelder, IARS Abstract 2010). Furthermore, a clinical model in pigs suggests less chemical injury from aspiration compared to a barrel shaped cuff (Lichtenthal, Abstract Critical Care 2010, 14(Suppl 1):P229). Human clinical studies are limited to data on reduced dye leakage compared to barrel-shaped cuffs (Mulier, ASA abstracts; D'Haese Acta Anaesthesiol Scand 2013).12
Currently, there is no evidence that patients with brief ventilation such as those undergoing routine surgery may benefit from actual outcomes with this tapered shape compared to regular tubes. Because the incidence of postoperative pneumonia in these patients is lower than those with prolonged ventilation, a large clinical data set would be necessary to evaluate any potential difference.
Since 2011, Oregon Health \& Science University (OHSU) has been documenting patient clinical care in a comprehensive point-of-care electronic medical record system (Centricity, General Electric, Fairfield, CT; EPIC, Verona, WI). This information can be collated to provide easy access to co-morbidities, clinical interventions, and ICD-9 discharge codes. In addition, OHSU is part of the National Surgical Quality Improvement Project (NSQIP). OHSU has been a collaborator in this effort since 2006 and collects data on 1,400 patients annually for vascular and general surgery patients (IRB 4621).
The identified incidence of postoperative pneumonia in our NSQIP patients at OHSU is 1.9%. This incidence is slightly below the national NSQIP average and below the risk-adjusted expected rate of postoperative pneumonia. With a large surgical population and access to detailed quality data from our electronic medical record system, OHSU lends itself well to a clinical investigation to improve patient care. As investigators, we have extensive experience with management of data systems for detailing patient outcomes.13
On December 1, 2012, OHSU instituted a practice change to transition from endotracheal tubes with a barrel-shaped cuff design to the Taperguard tube for all surgical patients. A quality assurance program was set up to monitor patient outcomes, including postoperative pneumonia, before and after this practice change. The investigators have developed this protocol as an expansion of the quality assurance program, to determine how this practice change has affected patient outcomes.
This study is designed as a chart review to collect data from all adult surgical patients at OHSU for the 18 months prior to the practice change (June 1, 2011 - November 30, 2012) and compare it to data for all adult patients having surgery during the 14.5 months following the practice change (December 1, 2012 - February 15, 2014). Subjects will be excluded if anesthesia was provided using a Hi-Lo, double lumen, reinforced, or laser endotracheal tube or a laryngeal mask airway. Data will be collected from the OHSU electronic medical records (Centricity and EPIC). We will gather all ICD-9 discharge coding related to postoperative pneumonia and link it to pertinent information from the patient's anesthesia record, including demographic and surgical case information. Postoperative pneumonia will be defined using the NSQIP definition (listed at the end of this protocol).
We anticipate that we will enroll approximately 40,000 subjects in the study. The identified incidence of postoperative pneumonia at OHSU currently is 1.9%. A power analysis was conducted to determine a meaningful sample size in light of a predicted improvement in pneumonia outcomes. To demonstrate a risk reduction from 1.9% to 1.5% with 80% power and 0.05 significance, 22,000 patients would need to be enrolled in the pre-intervention group and 16,000 patients in the post-intervention group.
The primary source of data for this study is the electronic medical record. The NSQIP database may be used for comparison and verification of the data collected.
During the study period, there have been no active institutional changes to address postoperative pneumonia and none are anticipated in the near future. Anesthesia techniques are not undergoing any major changes to address pneumonia outcomes and compliance with prophylactic antibiotic administration is optimized at OHSU. Similarly, the intensive care units implement a "bundle" practice to reduce pneumonia that includes GI prophylaxis, tracheal suctioning, elevated head of bed positioning, sedation vacation with spontaneous breathing trial once a day, and targeted antibiotic therapy.
A multiple logistic regression analysis will be employed to determine the rates of pneumonia between the use of a standard barrel-cuff designed ETT and the Taperguard ETT for the defined group of surgical patients. The regression analysis would be adjusted for confounding variables including ASA status, age, use of paralytic, RSI with cricoid pressure, weight, pre-existing lung disease.
While patient benefit from potential reduced micro aspiration may be assumed from preliminary data, additional costs associated with this new technology are not warranted without evidence of patient care benefit or reduced patient care costs. The ultimate outcome desired when selecting endotracheal tube and ventilation strategy is a reduction in lung injury, morbidity, and reduced costs. Because this new technology offers potential benefit, it is imperative that a large-scale clinical study confirm the hypothesis that pneumonia is reduced by altering cuff design before a change in practice can be advocated. Estimates of cost-savings achieved from potential positive data can be constructed. In this manner, the Taperguard tube has potential to demonstrate savings for hospitals and improved patient care.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
OTHER
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Standard Barrel-Cuff ETT
Standard Barrel-Cuff ETT use in surgical patients
No interventions assigned to this group
Taperguard ETT
Taperguard ETT use in surgical patients
No interventions assigned to this group
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Oregon Health and Science University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Michael Aziz
Associate Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Michael Aziz, MD
Role: PRINCIPAL_INVESTIGATOR
Oregon Health and Science University
References
Explore related publications, articles, or registry entries linked to this study.
Martini RP, Yanez ND, Treggiari MM, Tekkali P, Soelberg C, Aziz MF. Implementation of the TaperGuard endotracheal tube in an unselected surgical population to reduce postoperative pneumonia. BMC Anesthesiol. 2020 Aug 24;20(1):211. doi: 10.1186/s12871-020-01117-4.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Taperguard
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.