A Study to Assess Insulin Delivery With PaQ® in Patients With Type 2 Diabetes Mellitus
NCT ID: NCT02419859
Last Updated: 2016-07-26
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2015-02-28
2015-11-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Investigating the Safety and Effectiveness of Insulin Degludec in a Real World Population With Type 1 and 2 Diabetes Mellitus
NCT02392117
A Research Study to See How Well Weekly Insulin Icodec Maintains Blood Sugar Levels Compared to Daily Basal Insulins in Adults With Type 2 Diabetes
NCT07112339
A Study to Test How a New Long-acting Insulin Works in the Body of Patients With Type 2 Diabetes During Exercise and Prolonged Fasting
NCT06288412
A Study of LY3209590 in Participants With Type 2 Diabetes Mellitus
NCT03736785
Impact of Introducing Basaglar Insulin to the Treatment Regimen of Youth With Diabetes in Pakistan
NCT06717191
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
PaQ® Insulin Delivery Device
The intervention is continuous subcutaneous U 100 Insulin, Asp(B28)-rapid-acting insulin, at a constant basal rate of either 20, 24, 32, 40 or 50 U per day over 3 days and and bolus insulin as needed at meals in 2 U increments.
PaQ® Insulin Delivery Device
PaQ is a 3 day insulin delivery device which delivers U 100 rapid-acting insulin. Provides basal insulin at preset basal doses and bolus insulin (in 2 unit increments) with a push of a button.
Insulin, Asp(B28)-
a fast-acting analog of human insulin
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
PaQ® Insulin Delivery Device
PaQ is a 3 day insulin delivery device which delivers U 100 rapid-acting insulin. Provides basal insulin at preset basal doses and bolus insulin (in 2 unit increments) with a push of a button.
Insulin, Asp(B28)-
a fast-acting analog of human insulin
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Has a clinical diagnosis of T2DM, as determined by clinical history and medication usage;
* Has an A1C ≥ 7.0% and ≤ 11.0%;
* Is treated with basal-bolus insulin therapy (at least 2 injections per day) with or without OADs, and/or GLP-1 agonist for at least 3 months and has not had a change (addition or discontinuation of existing drug or change in dose) in their OADs for the last 8 weeks, (See Section 7.4 for definition of baseline basal bolus therapy);
* Determined by the investigator that insulin requirements to achieve glycemic targets can be met by the insulin capacity of the PaQ device;
* If on concomitant metformin, has serum creatinine \<1.5 mg/dL (male) or \<1.4 mg/dL (female);
* If female, and of child-bearing potential, has a negative urine pregnancy test at screening and must be using adequate means of contraception as determined by the Investigator;
* Is clinically euthyroid as judged by the Investigator;
* Is able to understand and sign the required study documents and comply with the CIP requirements;
* Is deemed capable by the Investigator to perform the requirements of the CIP, including use of PaQ, frequent self-monitoring of blood glucose.
Exclusion Criteria
* Is poorly compliant with prescribed self-monitoring of blood glucose, as determined by the Investigator;
* Is currently taking or has taken sulfonylureas within the last 2 months;
* Has a BMI greater than 40 kg/m2;
* Has experienced recurrent severe hypoglycemia (\> 2 episodes) requiring assistance during the past 6 months;
* Has existing dermal irritation/inflammation over the abdominal area that may interfere with use of PaQ, as determined by the Investigator;
* Has known clinically significant hypersensitivity to skin adhesives;
* Is female and if of child-bearing potential, is pregnant, lactating, or planning to become pregnant;
* Is currently being treated with or expected to require or undergo treatment with systemic steroids by oral, intravenous, or intramuscular route (inhaled with low systemic exposure is permitted);
* Currently abuses drugs or alcohol or has a history of abuse that in the Investigator's opinion would cause the individual to be non-compliant;
* Has received any investigational drug within 1 month;
* Has donated blood within 30 days;
* Has any significant medical condition (including current or past history of cardiovascular disease), laboratory findings, or medical history that in the Investigator's opinion may affect successful completion of the study and/or personal well-being;
* Is an immediate family member (spouse, parent, child, or sibling) of personnel directly affiliated with the study at the investigative site, or is personally directly affiliated with the study at the investigative site.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
CeQur Corporation
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Thomas Pieber, MD
Role: PRINCIPAL_INVESTIGATOR
Medical University of Graz
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Medical University of Graz
Graz, , Austria
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Mader JK, Lilly LC, Aberer F, Poettler T, Johns D, Trautmann M, Warner JL, Pieber TR. Improved glycaemic control and treatment satisfaction with a simple wearable 3-day insulin delivery device among people with Type 2 diabetes. Diabet Med. 2018 Oct;35(10):1448-1456. doi: 10.1111/dme.13708. Epub 2018 Jul 5.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CQR14002
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.