The Study of Rest Tremor Suppression by Using Electrical Muscle Stimulation

NCT ID: NCT02370108

Last Updated: 2015-02-24

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

PHASE1

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2015-02-28

Study Completion Date

2017-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study is aimed to study the safety and feasibility of electrical muscle stimulation (EMS) in suppression of tremor from various causes especially for rest tremor in Parkinson's disease.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Study method as follows:

* All subjects will be provided the information on this research study and informed consent will be sought for every subjects.
* All subjects (30 PD patients and 30 others tremor patients) will be interviewed by a movement disorders specialist or a trained interviewer for their demographic and clinical data.
* All PD patients will be examined for the severity of Parkinson's disease by a movement disorders specialist according the Unified Parkinson's disease Rating Scale (UPDRS), Hoehn and Yahr score, and tremor rating scale, during the 'on period' in order to determine the additional effect of EMS for suppression of tremor. Physical examinations of each patient will be recorded by the video recording for later reviewed.
* All essential tremor and dystonic tremor patients will be examined by a movement disorders specialist for the tremor severity according to the Fahn, Tolosa, Marin Tremor Rating Scale. Physical examinations of each patient will be recorded by the video recording for later reviewed.

All patient will be determined for feasibility to use EMS and safety of EMS. Pain will determined by visual analog scale.

* All patients will be monitored their hand tremor at resting position and postural position. The tremor analysis with accelerometer and gyroscope system (Parkinson Monitor V0.006 Beta) and the surface EMG (Nicolet EDX Viking) will be conducted. The surface EMG electrode will place over thenar muscle of the hand, which is the most predominant sided of tremor, for quantitative measurement and determination of tremor physiology.
* All participants data from surface EMG will be applied to The Matlab™ program (MathWorks Inc.) in order to modify the qualitative signals into quantitative parameters and performing the high-dimensional feature vectors, and later to determine the different efficacy in pulse amplitude of electrical muscle stimulation on feature vectors.
* The electrical muscle stimulation (Intensity™ Twin Stim® III) will be conducted by placement the 2 self-adhesive electrode (size 1.5 inches \* 1.5 inches) over thenar muscle and 1st\&2nd interrosseous muscle of the hand, which is the most predominant sided of tremor. The EMS will be stimulated PD patients on the rest position, whereas the other tremors patients in both rest position and postural position. The pulse amplitude will be slowly titration until provided the tetanic muscle contraction (motor threshold) without pain (all applied frequency is 50 Hz).
* All of examination will be taken for 30 minutes for each one subject.

Data Collection

* Demographic and clinical data: age, gender, clinical diagnosis, disease's duration and severity score for each subject according to establishing standard rating scale.
* Tremor parameters form Parkinson Monitor V0.006 Beta will be collected in both before and during EMS as 5 parameters: Peak magnitude, RMS, Angle, Frequency, Q
* The pulse amplitude from EMS will be recorded in every titration in order to determine the efficacy of EMS in difference pulse amplitude.
* The surface EMG and acceleration signal in difference pulse amplitude will be extracted and clustered data in order to analyze by using Matlab™, and performed the high-dimensional feature vectors for quantitative interpretation.

Data Analysis The statistical analysis in this study is based from SPSS program version 17. Categorical data will be analyzed for frequency and percentage. Continuous data will be analyzed by mean and standard deviation (SD). Non-parametric study would be preferred if the small sample size or in case of distribution of data do not present as normal distribution (determined by Kolmogorov-Smirnov test). The repeated ANOVA will be used for determined the efficacy of difference pulse amplitude on tremor suppression and the efficacy of EMS in the difference times in follow up periods.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Rest Tremor Parkinson's Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

PD patient

Parkinson's disease patients will get the electrical muscle stimulation at the most tremulous hand at 50 Hz frequency, maximal tolerate pulse amplitude (not over 20 mA), duration of stimulation for 10 second.

Group Type EXPERIMENTAL

electrical muscle stimulation

Intervention Type DEVICE

electrical muscle stimulation at hand muscle for reduction tremor

OT patients

others tremor patients will get the electrical muscle stimulation at the most tremulous hand at 50 Hz frequency, maximal tolerate pulse amplitude (not over 20 mA), duration of stimulation for 10 second.

Group Type EXPERIMENTAL

electrical muscle stimulation

Intervention Type DEVICE

electrical muscle stimulation at hand muscle for reduction tremor

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

electrical muscle stimulation

electrical muscle stimulation at hand muscle for reduction tremor

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* For PD patients

* Adults ≥ 18 years old.
* Patients with Parkinson's disease diagnosed according to the UKPDSBB criteria with predominantly feature of rest tremor that intractable to medically treatment.
* Informed consent For other tremor patients
* Adults ≥ 18 years old.
* Patients with essential tremor diagnosed according to the TRIG criteria for essential tremor or patients with dystonic tremor diagnosed according to the proposed definition in which their symptoms shared similar trait of medically intractable tremor.
* Informed consent

Exclusion Criteria

* For PD patients

* Patients with a history of cardiac arrhythmia, renal failure, hepatic failure, and pregnancy as well as those who had history of seizure or had the risk for tended to become seizure such as those who had focal brain lesions, encephalitis, and stroke patients.
* Patients with a history of hand surgery and implanted screws or wires in hand area that supposed to place a surface EMG or EMS, as well as those patients who were implanted for electrical devices such as cardiac pacemaker, pulse generator of deep brain stimulation,and intrathecal baclofen pump.
* Patients who cannot avoid the medication that may potentiate or attenuate tremor such as antihistamines, benzodiazepine, illicit drugs, and thyroid hormone supplement.

For other tremor patients

* Patients with a history of cardiac arrhythmia, renal failure, hepatic failure, and pregnancy as well as those who had history of seizure or had the risk for tended to become seizure such as those who had focal brain lesions, encephalitis, and stroke patients.
* Patients with a history of hand surgery and implanted screws or wires in hand area that supposed to place a surface EMG or EMS, as well as those patients who were implanted for electrical devices such as cardiac pacemaker, pulse generator of deep brain stimulation, and intrathecal baclofen pump.
* Patients who cannot avoid the medication that may potentiate or attenuate tremor such as antihistamines, benzodiazepine, illicit drugs, and thyroid hormone supplement.
Minimum Eligible Age

18 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Chulalongkorn University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Roongroj Bhidayasiri, MD, FRCP

Role: STUDY_DIRECTOR

Chulalongkorn University

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Onanong Jitkritsadakul, MD, MSc

Role: CONTACT

0863570212

Roongroj Bhidayasiri, MD, FRCP

Role: CONTACT

022564630

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

483/57

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.