Reproducibility of LipiView Ocular Surface Interferometer (LipiView) for Measuring Tear Lipid Layer Thickness
NCT ID: NCT01933165
Last Updated: 2014-06-10
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2013-09-30
2014-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
LipiView Ocular Surface Interferometer (LipiView) is a HSA-approved imaging device that has the ability to assess optical interference pattern produced by light reflected off the tear film in a safe and non-invasive manner.2 Software analysis of the image then measures the tear LLT, which is used to objectively quantify the diagnosis of lipid-deficient dry eye.
This current study aims to investigative the inter and intra-examiner reproducibility of measuring tear lipid layer thickness (LLT) with LipiView, which is used in our current clinical setting. LipiView has not been evaluated on its reproducibility of measuring tear lipid layer thickness. The study will also assess for correlation between the magnitude of tear LLT and the inter and intra-examiner reproducibility of LipiView.
Once this method is found to be repeatable, this can be used in future clinical settings and trials as an additional tool to investigate dry eye treatments.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Tear Layer Lipid Thickness in Pterygium Patient Before and After Surgery
NCT02160769
Validating the Diagnostic Accuracy of Mediview 2.0 Software as an Image Analysis Tool of Meibomian Glands
NCT01991132
Evaluation of the Repeatability and Reproducibility of Corneal Epithelial Thickness Mapping With SD-OCT
NCT02600546
Reproducibility of Anterior Segment Optical Coherence Tomography (AS-OCT) for Imaging Conjunctivochalasis
NCT01933178
Evaluation of the Repeatability and Reproducibility of AngioVue
NCT02911883
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Dry eye is a condition that affects 5-35% of the population.11 Common symptoms of this condition include eye irritation, heaviness of the eyelids, visual disturbances, tearing and light sensitivity.12 This significantly impacts the quality of life and vision of dry eye patients. In addition, there is a significant socioeconomic burden. In 2009, 54,051 patients sought treatment for dry eye in the Singapore National Eye Centre (SNEC). In total, the costs for dry eye medication amounted to $181,354.17.14 Additionally, dry eye affects work productivity which further adds on to the socioeconomic burden.15
Currently, the diagnosis and assessment of dry eye is hindered by tests that have poor repeatability, some of which cause discomfort due to their invasiveness. As a result most clinical studies involving dry eye treatment rely on symptomatic improvements as a primary outcome measure. However, symptomatic improvements are a poor measure in determining treatment effectiveness because with disease progression, the eye becomes desensitized from nerve damage. Also, it is common for patients to feel a reduction of discomfort of the eye before objective improvements can be noted by the clinician. An assessment based on symptoms alone is therefore inappropriate.13
Over the last few years, SNEC/SERI has built up a dedicated team of dry eye researchers for trials and evaluation of diagnostic devices. There is an increasing interest internationally, especially from industry, to partner us for testing of commercial products.
The LipiView Ocular Surface Interferometer is a HSA-approved imaging device that allows clinicians evaluate the characteristics and thickness of the tear lipid layer thickness (LLT) in a safe and non-invasive manner. The device utilizes white light from a LED source that is directed at the tear film over the inferior corneal region. Reflected light is captured by a high resolution camera and the optical inference pattern is evaluated by software to determine the LLT. 2 It also was found to correlate with other dry eye diagnostic tests, such as tear film break-up time (TBUT), Schirmer's test and corneal staining 3,4,5,6. LLT is also reported to better correlate with symptoms than other objective dry eye tests. 2
While several studies have investigated and shown the association between dry eye syndrome and low LLT 2,7,8,9, it is not known if LipiView would be able to make reproducible measurements of LLT for the objective diagnosis of dry eye syndrome.
Clinical importance Should this modality of imaging be shown to be repeatable, it can be incorporated into current protocol/workflow for assessment and monitoring of dry eye and treatment progress in our centre, as well as enhancing our capability to perform clinical trials and increase our international reputation.
Study Objectives and Purpose The primary purpose is to evaluate intra-examiner repeatability of the LipiView Ocular Surface Interferometer (LipiView) for imaging tear lipid layer thickness.
Study design:
Prospective study
Rationale:
Repeatability is an important issue in the objective assessment of dry eye. There is lack of studies that investigate LipiView for assessment of the tear film lipid layer thickness in dry eyes. LipiView is potentially useful as a non-invasive procedure for objective measurements of dry eyes.
Methods:
Participants and target sample size 20 healthy volunteers will be recruited for this study. During recruitment, a simple questionnaire is given to confirm for the absence of any dry eye symptoms. Each volunteer will also be given a study serial number to ensure anonymity.
All 20 volunteers will participate in the LipiView repeatability and inter-rater agreement study.
Visit schedules One visit is required for participants.
Duration of study:
10 months.
Procedures:
1. Assessment of Dry Eye Symptoms Participants will be asked to score and fill up a dry eye questionnaire that assesses the symptomatic severity of dry eyes in the participant and the extent of its disruption to daily activities. Basic biodata such as age, race, gender will also be recorded.
2. LipiView Ocular Surface Interferometer Tear Lipid Layer Thickness Measurement During the measurement of each eye, the participants place their chins on a chin rest and look at a single white light source for 30 seconds. During this period, participants are encouraged to blink freely at a comfortable rate which the assessor measures the LLT. Afterwards, the aforementioned steps will be repeated for the same eye by another assessor after a 5 minutes interval. Assessor 1 will perform the measurement at time 0 min, 10min and 20min while Assessor 2 will perform the measurement at time 5 min, 15 min, 25min.
Similar steps would be taken for the other eye. Therefore, 12 measurements would be taken altogether per participant. Between measurements, participants are advised not to rub or touch their eyes, or instill any eye drops or ointment.
Assessment of fluorescein tear break up time and corneal staining will be conducted only after LipiView LLT measurement.
3. Fluorescein Dye Tear Break-up Time (TBUT) Fluorescein dye is introduced onto the lower eyelid by a wetted fluorescein strip. The tear film will then be observed with blue light using a slit lamp to the point where it breaks. The time from the previous blink to the breaking of the tear film will be recorded to the nearest second.
4. Fluorescein Dye Corneal Staining After fluorescein dye is introduced, the cornea will be examined for green stains indicating epithelial erosion, a sign of damage due to dryness. The number of green stains and their location on the cornea (superior, central, inferior, temporal, nasal fields) will be recorded.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
LipiView
LipiView
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
LipiView
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Active ocular surface conditions such as infection or pterygium that may affect tear film stability.
* Any other specified reason as determined by clinical investigator.
21 Years
90 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Singapore National Eye Centre
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Louis Tong
Clinician-Scientist, Senior Consultant
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Louis Tong, PhD
Role: PRINCIPAL_INVESTIGATOR
Singapore National Eye Centre
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Singapore Eye Research Institute
Singapore, Singapore, Singapore
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2013/327/A
Identifier Type: OTHER
Identifier Source: secondary_id
R1028/43/2013
Identifier Type: -
Identifier Source: org_study_id
More Related Trials