Repeatability and Agreement of Anterior Segment Optical Coherence Tomography (AS-OCT) and Thermography

NCT ID: NCT01479790

Last Updated: 2013-02-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

40 participants

Study Classification

INTERVENTIONAL

Study Start Date

2011-06-30

Study Completion Date

2012-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Dry eye is a common condition that affects vision and quality of life in patients. Dry eye clinical research is limited to follow up of disease progression. Currently, most research outcomes are based on subjective patient complaints rather than objective assessment of the condition. Only few objective measurements for dry eye are available today and this is mainly the result of poor repeatability and inaccuracy.

This current study aims to evaluate 2 new non-invasive imaging techniques suitable for dry eye assessment.

Anterior segment optical coherence tomography (AS-OCT) is an imaging device that has the ability to image the tear meniscus of the eye in a safe and non-invasive manner. Image analysis can then indirectly determine the tear film volume. Improvements in the image resolution of these devices require a study that compares the repeatability and agreement of an older (Visante AS-OCT) and a newer instrument (Cirrus AS-OCT) which the current study aims to address.

Another method of evaluating dry eye disease is a novel technique that uses functional infrared thermography to measure tear evaporation rate. This study will also establish repeatability of measurements of the ocular surface temperature which are used to calculate tear evaporation rates.

Should these methods are found to be repeatable, they can be used in future clinical trials as an additional tool to investigate dry eye treatments.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Study Objectives and Purpose:

Part A - AS-OCT repeatability and agreement

1. The primary purpose of Part A is to compare the repeatability of the Cirrus with the Visante AS-OCT imaging system.
2. The second objective is to identify the level of agreement in the tear meniscus measurements taken by the Cirrus and Visante AS-OCT.

Part B - Tear evaporimetry with functional infra-red thermography

1. To evaluate the repeatability of Infrared thermography for ocular surface temperature measurements that are used for calculation of tear evaporation rates. If this is found to be acceptable, it will be correlated to tear meniscus parameters.
2. To determine whether this method is able to detect temperature changes of the ocular surface.

Study design:

Part A. Cross sectional study. Part B. Prospective study

Rationale:

Part A - AS-OCT repeatability and agreement Repeatability is an important issue in the objective assessment of dry eye. While previous studies have compared various methods of measuring the tear meniscus, including the use of Visante AS-OCT, current literature lacks studies that investigated the Cirrus AS-OCT for assessment of dry eye. With a higher resolution, the Cirrus is potentially useful as a non-invasive procedure for objective measurements of the tear meniscus.

Part B - Tear evaporimetry with functional infra-red thermography Current available methods to measure of tear evaporation rate have major limitations. This new method, however, is non-invasive, has no need for special eye drops or chambers and takes temperature measurements very quickly. This method is therefore extremely practical and provides many exciting possibilities for future trials.

Methods:

Participants and target sample size 40 volunteers from Singapore Eye Research Institute will be recruited for this study. Each volunteer will be given a study serial number to ensure anonymity.

20 will participate in the AS-OCT study. 20 will participate in the tear evaporimetry study.

Part A - AS-OCT repeatability and agreement Two AS-OCT imaging systems, namely Cirrus and the Visante, will be tested. All participants undergo acquisition of 2 images by the Visante AS-OCT, then 2 images by the Cirrus AS-OCT. Both images will be acquired by the same technician.

Part B - Tear evaporimetry with functional infra-red thermography In total, four pairs of thermographic sequences on the ocluar surface temperature from volunteers will be taken.

1. The volunteer will be seated in front of the thermographic camera and on each eye on thermographic sequence will be captured.
2. After 20 minutes, a second pair of thermographic sequences will be captured.
3. An eye mask with a temperature of not more than 40 deg C (confirmed by thermometer) will be worn by the volunteer for 5 minutes.
4. A third pair of thermographic sequences will be captured immediately after mask removal.
5. A fourth pair of thermographic sequences will be captured 1 hour after mask removal.

Between sequence acquisitions, the volunteer is allowed to move freely in the room. The temperature and humidity of the room will be kept constant during measurements.

Visit schedules:

Only one examination per ASOCT instrument for Part A is required. For Part B, all thermography will be performed on the same day.

If participants agree to have both ASOCT and tear evaporimetry done, then they will undergo Parts A and B. If not, they will be recruited for either Part A or Part B.

Duration of study: 1 day

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Dry Eye Syndromes

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

SINGLE_GROUP

Primary Study Purpose

SCREENING

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Visante AS-OCT and Cirrus AS-OCT

The tear meniscus is the thin concave strip of the tear film near the eyelid margins. During the acquisition the participants place their chins on a chin rest and look at a fixation light/target. This whole procedure should not take more than 5 minutes. The patients are allowed to blink freely except for during the acquisition time of less than 5 seconds. The procedure will be repeated for the upper and lower tear meniscus of both eyes.

Group Type NO_INTERVENTION

No interventions assigned to this group

Thermography measurement

In total, four pairs of thermographic sequences on the ocluar surface temperature from volunteers will be taken.

1. A thermographic sequence will be captured from each eye.
2. After 20 minutes, a second pair of thermographic sequences will be captured.
3. An eye mask with a temperature of not more than 40 deg C (will be worn by the volunteer for 5 minutes and a third pair of thermographic sequences will be captured immediately after mask removal.
4. A fourth pair of thermographic sequences will be captured 1 hour after mask removal.

Group Type EXPERIMENTAL

EyeGiene

Intervention Type DEVICE

The eye mask with a temperature of not more than 40 deg C (confirmed by thermometer) will be worn by the volunteer for 5 minutes.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

EyeGiene

The eye mask with a temperature of not more than 40 deg C (confirmed by thermometer) will be worn by the volunteer for 5 minutes.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

EyeGiene (Eyedetec Medical Inc., US)

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

\- Volunteers that are medically fit and willing to participate in this study.

Exclusion Criteria

* No eye surgery done within the previous 3 months
* Active ocular infection or pterygium that may affect tear film stability.
* Any other specified reason as determined by clinical investigator.
Minimum Eligible Age

21 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Singapore Eye Research Institute

OTHER

Sponsor Role collaborator

Nanchang University

OTHER

Sponsor Role collaborator

Singapore National Eye Centre

OTHER_GOV

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Louis Tong

Clinician-Scientist, Consultant

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Louis Tong, PhD

Role: PRINCIPAL_INVESTIGATOR

Singapore National Eye Centre

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Singapore Eye Research Institute

Singapore, Singapore, Singapore

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Singapore

References

Explore related publications, articles, or registry entries linked to this study.

Tan JH, Ng EY, Acharya UR. Evaluation of tear evaporation from ocular surface by functional infrared thermography. Med Phys. 2010 Nov;37(11):6022-34. doi: 10.1118/1.3495540.

Reference Type BACKGROUND
PMID: 21158314 (View on PubMed)

Savini G, Goto E, Carbonelli M, Barboni P, Huang D. Agreement between stratus and visante optical coherence tomography systems in tear meniscus measurements. Cornea. 2009 Feb;28(2):148-51. doi: 10.1097/ICO.0b013e31818526d0.

Reference Type BACKGROUND
PMID: 19158555 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2011/408/A

Identifier Type: OTHER

Identifier Source: secondary_id

R845/40/2011

Identifier Type: -

Identifier Source: org_study_id