Optimizing Closed-Loop Control of Type 1 Diabetes Mellitus in Adolescents
NCT ID: NCT01890954
Last Updated: 2022-09-13
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
17 participants
INTERVENTIONAL
2013-08-31
2014-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Closed-Loop Control in Young Children 5-8 Years Old Using DiAs Platform
NCT02750267
Automated Closed-loop in Children and Adolescents With Type 1 Diabetes
NCT02129868
Safety and Feasibility of a Self-Learning Bolus Calculator With Simplified Meal Announcement in Adolescents With Type 1 Diabetes Using Automated Insulin Delivery
NCT07212179
Hybrid Closed-Loop Control With Smart Prandial Insulin Dosing in Type 1 Diabetes
NCT04878120
Hypoglycemia Prevention After Exercise in Adolescent T1DM Patients Using a Control to Range System
NCT01390259
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
DiAs-closed-loop system
eight hours using Closed Loop Control (DiAs) under both, miss insulin bolus for 30 grams of carbohydrates snack or under bolus for an 80 grams of carbohydrates lunch
Diabetes Assistant (DiAs)
Diabetes Assistance (DiAs) is a software residing in a Smartphone that contains the algorithms to regulate and control insulin deliveries (insulin bolus for: Basal rate, meal insulin and correction bolus) with inputs glucose values from a CGM and outputs insulin infusion by an insulin pump
Sensor Augmented Pump
8 hours observational under both, missed insulin bolus for 30 gr carbohydrates snack and under bolus for an 80 gr carbohydrates lunch. Sensor augmented pump used the patients own insulin settings (basal rate, meal boluses and correction boluses) and a CGM provided by the study team to be used during admission. No DiAs use during this admission.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Diabetes Assistant (DiAs)
Diabetes Assistance (DiAs) is a software residing in a Smartphone that contains the algorithms to regulate and control insulin deliveries (insulin bolus for: Basal rate, meal insulin and correction bolus) with inputs glucose values from a CGM and outputs insulin infusion by an insulin pump
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Clinical diagnosis of type 1 diabetes mellitus for at least 2 years as noted by the following:
Criteria for documented hyperglycemia (at least 1 criterion must be met):
* Fasting glucose ≥126 mg/dL - confirmed
* Two-hour Oral Glucose Tolerance Test (OGTT) ≥200 mg/dL - confirmed
* Hemoglobin A1c (HbA1c) ≥6.5% documented by history - confirmed
* Random glucose ≥200 mg/dL with symptoms
* No data at diagnosis is available but the participant has a convincing history of hyperglycemia consistent with diabetes
Criteria for requiring insulin at diagnosis (at least 1 criterion must be met):
* Participant required insulin at diagnosis and continually thereafter
* Participant did not start insulin at diagnosis but upon investigator review likely needed insulin (significant hyperglycemia that did not respond to oral agents) and did require insulin eventually and used continually
* Participant did not start insulin at diagnosis but continued to be hyperglycemic, had positive islet cell antibodies - consistent with Latent Autoimmune Diabetes in Adults (LADA) and did require insulin eventually and used continually
3. Use of an insulin pump to treat his/her diabetes for at least 6 months
4. Actively using a carbohydrate (CHO) /insulin ratio for insulin bolus adjustments in order to keep blood glucose in a predefined range
5. Tanner stage II or greater based on physician exam
6. HbA1c between \<10.5% as measured with DCA2000 or equivalent device
7. Not currently known to be pregnant, breast feeding, or intending to become pregnant (females)
8. Demonstration of proper mental status and cognition for the study
9. Willingness to avoid consumption of acetaminophen-containing products during the study visits involving DexCom use
10. Self-reported behavior of snacking without insulin coverage or under bolus for meals
11. Willingness to consume a 30 grams snack without insulin coverage and willingness to bolus 75 % of usual treatment for an 80 grams lunch during both admissions
12. Willingness to remove home CGM for admissions if the subject typically wears a CGM
13. Medication stability in the preceding two months if taking antihypertensive, thyroid, anti-depressant or lipid lowering medication
14. Reported history of missed or inaccurate bolus treatments at meal time
Exclusion Criteria
2. In adherence with the One Touch Ultra 2 User Guide, subjects with hematocrit levels below 30% or above 55% will be excluded. Severe hypoglycemia resulting in seizure or loss of consciousness in the 12 months prior to enrollment
3. Pregnancy; breast feeding, or intention of becoming pregnant
4. Uncontrolled arterial hypertension (based on resting blood pressure \> 95 percentile as listed according to age and height percentile in the Harriet Lane Handbook of Pediatrics)
5. Conditions which may increase the risk of hypoglycemia such as uncontrolled coronary artery disease during the previous year (e.g. history of myocardial infarction, acute coronary syndrome, therapeutic coronary intervention, coronary bypass or stenting procedure, stable or unstable angina, episode of chest pain of cardiac etiology with documented electrocardiogram (EKG) changes, or positive stress test or catheterization with coronary blockages \>50%), congestive heart failure, history of cerebrovascular event, seizure disorder, syncope, adrenal insufficiency, neurologic disease or atrial fibrillation
6. History of a systemic or deep tissue infection with methicillin-resistant staph aureus or Candida albicans
7. History of arrythmia
8. Use of a device that may pose electromagnetic compatibility issues and/or radiofrequency interference with the DexCom CGM (implantable cardioverter-defibrillator, electronic pacemaker, neurostimulator, intrathecal pump, and cochlear implants)
9. Anticoagulant therapy other than aspirin
10. Oral steroids
11. Medical condition requiring use of an acetaminophen-containing medication that cannot be withheld for for 24 hours before CGM insertions until the end of each the study admissions.
12. Psychiatric disorders that would interfere with study tasks (e.g. inpatient psychiatric treatment within 6 months prior to enrollment)
13. Mental incapacity, unwillingness or language barriers precluding adequate understanding or cooperation
14. Known current or recent alcohol or drug abuse
15. Medical conditions that would make operating a CGM, the DiAs cell phone, or insulin pump difficult (e.g. blindness, severe arthritis, immobility)
16. Any skin condition that prevents sensor or pump placement on the abdomen or arm (e.g. bad sunburn, pre-existing dermatitis, intertrigo, psoriasis, extensive scarring, cellulitis)
17. Impaired hepatic function measured as alanine aminotransferase or aspartate aminotransferase ≥ three times the upper reference limit
18. Impaired renal function measured as creatinine \>1.2 times above the upper limit of normal
19. Uncontrolled microvascular (diabetic) complications (other than diabetic non-proliferative retinopathy), such as history of laser coagulation, proliferative diabetic retinopathy, known diabetic nephropathy (other than microalbuminuria with normal creatinine) or neuropathy requiring treatment
20. Active gastroparesis requiring current medical therapy
21. Uncontrolled thyroid disease
22. Known bleeding diathesis or dyscrasia
23. Known allergy to medical adhesives, components of the insulin pump insertion set or continuous glucose monitor sensor
24. Active enrollment in another clinical trial
25. Use of anti-diabetic agents other than continuous subcutaneous insulin infusion (CSII) including long-acting insulin, intermediate-acting insulin, metformin, sulfonylureas, meglitinides, thiazolidinediones, dipeptidyl peptidase 4 (DPP-4) inhibitors, glucagon-like peptide 1 agonists and alpha-glucosidase inhibitors
26. Subjects with basal rates less than 0.01 units/hour
RESTRICTIONS ON USE OF OTHER DRUGS OR TREATMENTS
1. Use of anti-diabetic agents other than CSII including long-acting insulin, intermediate-acting insulin, metformin, sulfonylureas, meglitinides, thiazolidinediones, DPP-4, inhibitors, glucagon-like peptide 1 agonists, and alpha-glucosidase inhibitors.
2. Acetaminophen will be restricted 24 hours before the insertion of not be allowed while the continuous glucose monitor is in use.
3. Medications that block symptoms of hypoglycemia, including but not limited to beta blockers.
4. Subjects on amylin analogs will be asked to withhold the medication during the outpatient admissions.
13 Years
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Virginia
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Daniel R. Chernavvsky, MD, CRC
Role: PRINCIPAL_INVESTIGATOR
University of Virginia
Mark DeBoer, MD
Role: PRINCIPAL_INVESTIGATOR
University of Virginia
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Virginia Center for Diabetes Technology
Charlottesville, Virginia, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Chernavvsky DR, DeBoer MD, Keith-Hynes P, Mize B, McElwee M, Demartini S, Dunsmore SF, Wakeman C, Kovatchev BP, Breton MD. Use of an artificial pancreas among adolescents for a missed snack bolus and an underestimated meal bolus. Pediatr Diabetes. 2016 Feb;17(1):28-35. doi: 10.1111/pedi.12230. Epub 2014 Oct 27.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
16890
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.