Optimizing Closed-Loop Control of Type 1 Diabetes Mellitus in Adolescents

NCT ID: NCT01890954

Last Updated: 2022-09-13

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

17 participants

Study Classification

INTERVENTIONAL

Study Start Date

2013-08-31

Study Completion Date

2014-02-28

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to use a closed-loop Control-to-Range (CTR) system in adolescents with type 1 diabetes in an outpatient setting, and to evaluate the CTR system's ability to significantly improve blood glucose levels when an insulin bolus is omitted for a 30 gram carbohydrate snack and when insulin bolus is insufficient for the amount of carbohydrates consumed for a meal. The primary objective of this study is to use a closed-loop Control-to-Range (CTR) system to significantly reduce the post-prandial blood glucose excursion in adolescents with type 1 diabetes who omit and/or under-bolus insulin for either snacks or meals. Up to 20 subjects aged ≥13 and ≤18 years old will be tested.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The purpose of this study is to use a closed-loop Control-to-Range (CTR) system in adolescents with type 1 diabetes in an outpatient setting, and to evaluate the CTR system's ability to significantly improve blood glucose levels when an insulin bolus is omitted for a 30 gram carbohydrate snack and when insulin bolus is insufficient for the amount of carbohydrates consumed for a meal. The CTR system is comprised of two algorithmic layers: (i) A Safety Supervision Module (SSM) which contains a predictive insulin request dampener (or brakes); (ii) a Range Correction Module (RCM), consisting in (a) a Hyperglycemia Mitigation System, and (b) Insulin on Board controller. Both modules will receive continuous glucose monitoring (CGM) and historical insulin delivery data. The SSM will monitor the safety of the subject's continuous subcutaneous insulin infusion pump (CSII) to prevent hypoglycemia. The RCM will be responsible for optimizing blood glucose (BG) control and mitigating postprandial hyperglycemic excursions through a mix of increased basal rate and, potentially, isolated insulin boluses. To run CTR, we will use our wearable artificial pancreas platform, known as DiAs (Diabetes Assistant) which consists of a smart phone running CTR and connected to standard insulin delivery and CGM devices.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes Mellitus, Type 1

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

DiAs-closed-loop system

eight hours using Closed Loop Control (DiAs) under both, miss insulin bolus for 30 grams of carbohydrates snack or under bolus for an 80 grams of carbohydrates lunch

Group Type ACTIVE_COMPARATOR

Diabetes Assistant (DiAs)

Intervention Type DEVICE

Diabetes Assistance (DiAs) is a software residing in a Smartphone that contains the algorithms to regulate and control insulin deliveries (insulin bolus for: Basal rate, meal insulin and correction bolus) with inputs glucose values from a CGM and outputs insulin infusion by an insulin pump

Sensor Augmented Pump

8 hours observational under both, missed insulin bolus for 30 gr carbohydrates snack and under bolus for an 80 gr carbohydrates lunch. Sensor augmented pump used the patients own insulin settings (basal rate, meal boluses and correction boluses) and a CGM provided by the study team to be used during admission. No DiAs use during this admission.

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Diabetes Assistant (DiAs)

Diabetes Assistance (DiAs) is a software residing in a Smartphone that contains the algorithms to regulate and control insulin deliveries (insulin bolus for: Basal rate, meal insulin and correction bolus) with inputs glucose values from a CGM and outputs insulin infusion by an insulin pump

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Closed-Loop system

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. ≥13 and ≤18 years old
2. Clinical diagnosis of type 1 diabetes mellitus for at least 2 years as noted by the following:

Criteria for documented hyperglycemia (at least 1 criterion must be met):
* Fasting glucose ≥126 mg/dL - confirmed
* Two-hour Oral Glucose Tolerance Test (OGTT) ≥200 mg/dL - confirmed
* Hemoglobin A1c (HbA1c) ≥6.5% documented by history - confirmed
* Random glucose ≥200 mg/dL with symptoms
* No data at diagnosis is available but the participant has a convincing history of hyperglycemia consistent with diabetes

Criteria for requiring insulin at diagnosis (at least 1 criterion must be met):
* Participant required insulin at diagnosis and continually thereafter
* Participant did not start insulin at diagnosis but upon investigator review likely needed insulin (significant hyperglycemia that did not respond to oral agents) and did require insulin eventually and used continually
* Participant did not start insulin at diagnosis but continued to be hyperglycemic, had positive islet cell antibodies - consistent with Latent Autoimmune Diabetes in Adults (LADA) and did require insulin eventually and used continually
3. Use of an insulin pump to treat his/her diabetes for at least 6 months
4. Actively using a carbohydrate (CHO) /insulin ratio for insulin bolus adjustments in order to keep blood glucose in a predefined range
5. Tanner stage II or greater based on physician exam
6. HbA1c between \<10.5% as measured with DCA2000 or equivalent device
7. Not currently known to be pregnant, breast feeding, or intending to become pregnant (females)
8. Demonstration of proper mental status and cognition for the study
9. Willingness to avoid consumption of acetaminophen-containing products during the study visits involving DexCom use
10. Self-reported behavior of snacking without insulin coverage or under bolus for meals
11. Willingness to consume a 30 grams snack without insulin coverage and willingness to bolus 75 % of usual treatment for an 80 grams lunch during both admissions
12. Willingness to remove home CGM for admissions if the subject typically wears a CGM
13. Medication stability in the preceding two months if taking antihypertensive, thyroid, anti-depressant or lipid lowering medication
14. Reported history of missed or inaccurate bolus treatments at meal time

Exclusion Criteria

1. Diabetic ketoacidosis (DKA) within the 6 months prior to enrollment
2. In adherence with the One Touch Ultra 2 User Guide, subjects with hematocrit levels below 30% or above 55% will be excluded. Severe hypoglycemia resulting in seizure or loss of consciousness in the 12 months prior to enrollment
3. Pregnancy; breast feeding, or intention of becoming pregnant
4. Uncontrolled arterial hypertension (based on resting blood pressure \> 95 percentile as listed according to age and height percentile in the Harriet Lane Handbook of Pediatrics)
5. Conditions which may increase the risk of hypoglycemia such as uncontrolled coronary artery disease during the previous year (e.g. history of myocardial infarction, acute coronary syndrome, therapeutic coronary intervention, coronary bypass or stenting procedure, stable or unstable angina, episode of chest pain of cardiac etiology with documented electrocardiogram (EKG) changes, or positive stress test or catheterization with coronary blockages \>50%), congestive heart failure, history of cerebrovascular event, seizure disorder, syncope, adrenal insufficiency, neurologic disease or atrial fibrillation
6. History of a systemic or deep tissue infection with methicillin-resistant staph aureus or Candida albicans
7. History of arrythmia
8. Use of a device that may pose electromagnetic compatibility issues and/or radiofrequency interference with the DexCom CGM (implantable cardioverter-defibrillator, electronic pacemaker, neurostimulator, intrathecal pump, and cochlear implants)
9. Anticoagulant therapy other than aspirin
10. Oral steroids
11. Medical condition requiring use of an acetaminophen-containing medication that cannot be withheld for for 24 hours before CGM insertions until the end of each the study admissions.
12. Psychiatric disorders that would interfere with study tasks (e.g. inpatient psychiatric treatment within 6 months prior to enrollment)
13. Mental incapacity, unwillingness or language barriers precluding adequate understanding or cooperation
14. Known current or recent alcohol or drug abuse
15. Medical conditions that would make operating a CGM, the DiAs cell phone, or insulin pump difficult (e.g. blindness, severe arthritis, immobility)
16. Any skin condition that prevents sensor or pump placement on the abdomen or arm (e.g. bad sunburn, pre-existing dermatitis, intertrigo, psoriasis, extensive scarring, cellulitis)
17. Impaired hepatic function measured as alanine aminotransferase or aspartate aminotransferase ≥ three times the upper reference limit
18. Impaired renal function measured as creatinine \>1.2 times above the upper limit of normal
19. Uncontrolled microvascular (diabetic) complications (other than diabetic non-proliferative retinopathy), such as history of laser coagulation, proliferative diabetic retinopathy, known diabetic nephropathy (other than microalbuminuria with normal creatinine) or neuropathy requiring treatment
20. Active gastroparesis requiring current medical therapy
21. Uncontrolled thyroid disease
22. Known bleeding diathesis or dyscrasia
23. Known allergy to medical adhesives, components of the insulin pump insertion set or continuous glucose monitor sensor
24. Active enrollment in another clinical trial
25. Use of anti-diabetic agents other than continuous subcutaneous insulin infusion (CSII) including long-acting insulin, intermediate-acting insulin, metformin, sulfonylureas, meglitinides, thiazolidinediones, dipeptidyl peptidase 4 (DPP-4) inhibitors, glucagon-like peptide 1 agonists and alpha-glucosidase inhibitors
26. Subjects with basal rates less than 0.01 units/hour

RESTRICTIONS ON USE OF OTHER DRUGS OR TREATMENTS

1. Use of anti-diabetic agents other than CSII including long-acting insulin, intermediate-acting insulin, metformin, sulfonylureas, meglitinides, thiazolidinediones, DPP-4, inhibitors, glucagon-like peptide 1 agonists, and alpha-glucosidase inhibitors.
2. Acetaminophen will be restricted 24 hours before the insertion of not be allowed while the continuous glucose monitor is in use.
3. Medications that block symptoms of hypoglycemia, including but not limited to beta blockers.
4. Subjects on amylin analogs will be asked to withhold the medication during the outpatient admissions.
Minimum Eligible Age

13 Years

Maximum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Virginia

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Daniel R. Chernavvsky, MD, CRC

Role: PRINCIPAL_INVESTIGATOR

University of Virginia

Mark DeBoer, MD

Role: PRINCIPAL_INVESTIGATOR

University of Virginia

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Virginia Center for Diabetes Technology

Charlottesville, Virginia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Chernavvsky DR, DeBoer MD, Keith-Hynes P, Mize B, McElwee M, Demartini S, Dunsmore SF, Wakeman C, Kovatchev BP, Breton MD. Use of an artificial pancreas among adolescents for a missed snack bolus and an underestimated meal bolus. Pediatr Diabetes. 2016 Feb;17(1):28-35. doi: 10.1111/pedi.12230. Epub 2014 Oct 27.

Reference Type RESULT
PMID: 25348683 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

16890

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Diabeloop for Teens
NCT04725591 COMPLETED NA