Intraprocedural Intraaortic Embolic Protection With the EmbolX Device in Patients Undergoing Transaortic Transcatheter Aortic Valve Implantation
NCT ID: NCT01735513
Last Updated: 2016-05-12
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
30 participants
INTERVENTIONAL
2012-07-31
2015-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Cerebral Hemodynamics and Microemboli During Placement of Relay®Branch Thoracic Stent-Graft System
NCT05155956
Treovance Stent-Graft With Navitel Delivery System for Patients With Infrarenal Abdominal Aortic Aneurysms
NCT01328197
False Lumen Treatment for Prevention of Aortic Growth Using Shape Memory Polymer - First-in-Human Study
NCT06550986
Medical & Economical Evaluation of Fenestrated & Branched Stent-grafts to Treat Complex Thoracal Abdominal Aneurysms
NCT01354821
Clinical Study of the Treovance Stent-Graft for Patients With Abdominal Aortic Aneurysms
NCT02009644
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
SINGLE_GROUP
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Transaortic TAVI with EmbolX
Subjects are randomized into this arm to receive a transaortic transcatheter aortic valve implantation with the use of the embolic protection device "EmbolX"
Intra-aortic embolic protection management system; Embol-X
The Embol-X system is positioned within the aorta to capture emboli, such as blood clots or tissue fragments, to prevent them from traveling through a patient's bloodstream during TAVI. The EMBOL-X system features a small, expandable, polyester-mesh filtration system that is placed inside the aorta above the aortic clamp during open-heart surgery or transaortic TAVI procedures, where it captures particles in the bloodstream that otherwise might have remained in the patient's circulatory system. A recent presentation characterized the removal of aortic cross-clamps as creating in some patients "embolic showers" which have the potential to cause neurocognitive complications, stroke and other organ damage. In documented procedures, 97% of EMBOL-X system filters showed detectable captured embolic matter, visible proof that the system is removing potentially dangerous emboli from the bloodstream.
Transaortic TAVI without EmbolX
Subjects are randomized into this arm to receive a transaortic transcatheter aortic valve implantation without the use of the embolic protection device "EmbolX"
Intra-aortic embolic protection management system; Embol-X
The Embol-X system is positioned within the aorta to capture emboli, such as blood clots or tissue fragments, to prevent them from traveling through a patient's bloodstream during TAVI. The EMBOL-X system features a small, expandable, polyester-mesh filtration system that is placed inside the aorta above the aortic clamp during open-heart surgery or transaortic TAVI procedures, where it captures particles in the bloodstream that otherwise might have remained in the patient's circulatory system. A recent presentation characterized the removal of aortic cross-clamps as creating in some patients "embolic showers" which have the potential to cause neurocognitive complications, stroke and other organ damage. In documented procedures, 97% of EMBOL-X system filters showed detectable captured embolic matter, visible proof that the system is removing potentially dangerous emboli from the bloodstream.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Intra-aortic embolic protection management system; Embol-X
The Embol-X system is positioned within the aorta to capture emboli, such as blood clots or tissue fragments, to prevent them from traveling through a patient's bloodstream during TAVI. The EMBOL-X system features a small, expandable, polyester-mesh filtration system that is placed inside the aorta above the aortic clamp during open-heart surgery or transaortic TAVI procedures, where it captures particles in the bloodstream that otherwise might have remained in the patient's circulatory system. A recent presentation characterized the removal of aortic cross-clamps as creating in some patients "embolic showers" which have the potential to cause neurocognitive complications, stroke and other organ damage. In documented procedures, 97% of EMBOL-X system filters showed detectable captured embolic matter, visible proof that the system is removing potentially dangerous emboli from the bloodstream.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* bicuspid aortic valve
* aortic annulus diameter ≤18 or ≥27 mm
* procelain aorta
* unprotected left main disease
* recent myocardial infarction or cerebrovascular event
* sepsis or active endocarditis
* severe aortic atheroma
* left ventricular or atrial thrombus
* active peptic ulcer
* bleeding diathesis
* hypersensitivity to antiplatelet therapy
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University Hospital, Essen
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Matthias Thielmann
PD. Dr. med. Matthias Thielmann
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of Thoracic and Cardiovascular Surgery, West-German Heart Center Essen, University Duisburg-Essen
Essen, , Germany
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Wendt D, Kleinbongard P, Knipp S, Al-Rashid F, Gedik N, El Chilali K, Schweter S, Schlamann M, Kahlert P, Neuhauser M, Forsting M, Erbel R, Heusch G, Jakob H, Thielmann M. Intraaortic Protection From Embolization in Patients Undergoing Transaortic Transcatheter Aortic Valve Implantation. Ann Thorac Surg. 2015 Aug;100(2):686-91. doi: 10.1016/j.athoracsur.2015.03.119.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
WDHZ-TC-TAo-EmbolX
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.