Intraprocedural Intraaortic Embolic Protection With the EmbolX Device in Patients Undergoing Transaortic Transcatheter Aortic Valve Implantation

NCT ID: NCT01735513

Last Updated: 2016-05-12

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

30 participants

Study Classification

INTERVENTIONAL

Study Start Date

2012-07-31

Study Completion Date

2015-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Study hypothesis: Reduction of cerebral embolic lesions during transcatheter aortic valve implantation by the use of an embolic protection device.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Transaortic Transcatheter Aortic Valve Implantation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Transaortic TAVI with EmbolX

Subjects are randomized into this arm to receive a transaortic transcatheter aortic valve implantation with the use of the embolic protection device "EmbolX"

Group Type EXPERIMENTAL

Intra-aortic embolic protection management system; Embol-X

Intervention Type DEVICE

The Embol-X system is positioned within the aorta to capture emboli, such as blood clots or tissue fragments, to prevent them from traveling through a patient's bloodstream during TAVI. The EMBOL-X system features a small, expandable, polyester-mesh filtration system that is placed inside the aorta above the aortic clamp during open-heart surgery or transaortic TAVI procedures, where it captures particles in the bloodstream that otherwise might have remained in the patient's circulatory system. A recent presentation characterized the removal of aortic cross-clamps as creating in some patients "embolic showers" which have the potential to cause neurocognitive complications, stroke and other organ damage. In documented procedures, 97% of EMBOL-X system filters showed detectable captured embolic matter, visible proof that the system is removing potentially dangerous emboli from the bloodstream.

Transaortic TAVI without EmbolX

Subjects are randomized into this arm to receive a transaortic transcatheter aortic valve implantation without the use of the embolic protection device "EmbolX"

Group Type ACTIVE_COMPARATOR

Intra-aortic embolic protection management system; Embol-X

Intervention Type DEVICE

The Embol-X system is positioned within the aorta to capture emboli, such as blood clots or tissue fragments, to prevent them from traveling through a patient's bloodstream during TAVI. The EMBOL-X system features a small, expandable, polyester-mesh filtration system that is placed inside the aorta above the aortic clamp during open-heart surgery or transaortic TAVI procedures, where it captures particles in the bloodstream that otherwise might have remained in the patient's circulatory system. A recent presentation characterized the removal of aortic cross-clamps as creating in some patients "embolic showers" which have the potential to cause neurocognitive complications, stroke and other organ damage. In documented procedures, 97% of EMBOL-X system filters showed detectable captured embolic matter, visible proof that the system is removing potentially dangerous emboli from the bloodstream.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Intra-aortic embolic protection management system; Embol-X

The Embol-X system is positioned within the aorta to capture emboli, such as blood clots or tissue fragments, to prevent them from traveling through a patient's bloodstream during TAVI. The EMBOL-X system features a small, expandable, polyester-mesh filtration system that is placed inside the aorta above the aortic clamp during open-heart surgery or transaortic TAVI procedures, where it captures particles in the bloodstream that otherwise might have remained in the patient's circulatory system. A recent presentation characterized the removal of aortic cross-clamps as creating in some patients "embolic showers" which have the potential to cause neurocognitive complications, stroke and other organ damage. In documented procedures, 97% of EMBOL-X system filters showed detectable captured embolic matter, visible proof that the system is removing potentially dangerous emboli from the bloodstream.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Embol-X, Edwards Lifesciences, Irvine, CA, USA. The EMBOL- X intra-aortic embolic management system.

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Patients with symptomatic severe aortic valve stenosis (valve area \<0.8 cm2) are considered candidates for TAVI (TAVR) if they have a logistic European System for Cardiac Operative Risk Evaluation score (EuroSCORE) ≥15% or surgery is deemed to be at excessive risk because of comorbidities and other risk factors not being captured by these scoring systems. Indication for TAVI in the individual patient is discussed in a consensus conference of cardiologists and cardiac surgeons, and patient's or physician's preference alone is not considered adequate for decision making. The performance of TAVI in these patients is approved by the local authorities. All patients have to agree to participate in the study, and written informed consent is obtained.

Exclusion Criteria

Patients are excluded from TAVI (TAVR) in the presence of any of the following conditions:

* bicuspid aortic valve
* aortic annulus diameter ≤18 or ≥27 mm
* procelain aorta
* unprotected left main disease
* recent myocardial infarction or cerebrovascular event
* sepsis or active endocarditis
* severe aortic atheroma
* left ventricular or atrial thrombus
* active peptic ulcer
* bleeding diathesis
* hypersensitivity to antiplatelet therapy
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University Hospital, Essen

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Matthias Thielmann

PD. Dr. med. Matthias Thielmann

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Department of Thoracic and Cardiovascular Surgery, West-German Heart Center Essen, University Duisburg-Essen

Essen, , Germany

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Germany

References

Explore related publications, articles, or registry entries linked to this study.

Wendt D, Kleinbongard P, Knipp S, Al-Rashid F, Gedik N, El Chilali K, Schweter S, Schlamann M, Kahlert P, Neuhauser M, Forsting M, Erbel R, Heusch G, Jakob H, Thielmann M. Intraaortic Protection From Embolization in Patients Undergoing Transaortic Transcatheter Aortic Valve Implantation. Ann Thorac Surg. 2015 Aug;100(2):686-91. doi: 10.1016/j.athoracsur.2015.03.119.

Reference Type DERIVED
PMID: 26234838 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

WDHZ-TC-TAo-EmbolX

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.