Detection of Pleural Effusion by Internal Thoracic Impedance Method
NCT ID: NCT01601444
Last Updated: 2012-05-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
100 participants
INTERVENTIONAL
2012-06-30
2013-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Radiographic examination, widely used for detecting pleural effusion ,is not suitable for prolonged monitoring of patients at high risk of developing PLE especially ambulatory or at home The currently available methods for monitoring and early detection such as the measurement of pulmonary capillary wedge pressure or measurement by double indicator thermodilution, are not reliable enough and may themselves lead to complications.
Measuring internal thoracic impedance (ITI), the main component of which is lung impedance, is a noninvasive and safe method. PLE will be diagnosed in accordance with well-accepted clinical signs(dyspnea, cyanosis, pulmonary rales, crepitations, arterial hypoxemia) and roentgenological criteria
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Randomized Study Comparing Pleural Drainage by Videothoracoscopy to Medical Drainage in Infectious Pleural Effusion
NCT01994499
Mini Thoracoscopy vs Semirigid Thoracoscopy in Exudative Pleural Effusions
NCT02851927
Mini Invasive Endomicroscopy of the Pleura for Malignancies Diagnosis
NCT04731129
Minirigid Versus Conventional Rigid Thoracoscopy in Undiagnosed Pleural Effusions
NCT03449602
Medical Thoracoscopy With Flexible Bronchoscopy Versus Semi-Rigid Pleuroscope in Pleural Effusion (FLEXPLEUR)
NCT06162429
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Radiographic examination, widely used for detecting pleural effusion ,is not suitable for prolonged monitoring of patients at high risk of developing PLE especially ambulatory or at home (1-9).
The currently available methods for monitoring and early detection such as the measurement of pulmonary capillary wedge pressure or measurement by double indicator thermodilution, are not reliable enough and may themselves lead to complications(2-8).
Yu C-M et al.(9) recently reported successful prediction of CPE by a surgically implanted impedance plethysmograph integrated into a pacemaker . The system was shown to be sufficiently sensitive for cardiogenic pulmonary edema preceding. However this method is invasive and not suitable for wide use (9).
Therefore, these methods are seldom employed for the detection of PLE (3-7). Thus, a safe and accurate technique for early detection and monitoring of PlEf would be of great clinical value. The changes in the blood and extravascular fluid content in the lungs in humans and animals can be easily monitored using a noninvasive and totally safe procedure based on impedance plethysmography (5-12-). This method is based on the fact that the impedance of the lungs decreases with the increase in the fluid and free ions content in them (8,13,). However, it proved to be unsuitable for preclinical stage monitoring of PLE (2-8) for several reasons, mainly the low sensitivity of the existing impedance plethysmographs. This is due to the high skin-electrode contact resistance (13,14), which is of an order of magnitude high erthan the impedance of the lung.
After cleaning the skin of fats with alcohol and moistening it with electrode paste, the value of the skin electrode contact resistance is approximately 400- 500 ohm (11-13). Therefore, for two measuring electrodes (front and back of the chest), this value must be 800-1000 ohm.
Total transthoracic impedance (TTI) consists of internal thoracic impedance (ITI) and skin contact impedance. The TTI may vary from 920 to 1230 ohm in different individuals (11-13). However, change of TTI in PLE was reported by others to vary in the range of 2-16 ohm (7-9, 11-18), which is approximately1% of TTI and 1.5% of skin contact impedance. Monitors used in previous works were not sensitive enough to detect the relatively small changes in pulmonary impedance(2-7).
In addition, during prolonged monitoring, the skin-electrode contact impedance may also change (13,14) due to penetration of the ions from sweat into the electrode paste and drying of the paste. It may significantly exceed the change in the impedance of the lung caused by the development of cardiogenic pulmonary edema (2-7). Kubicek et al. (10) attempted to develop a method in which a tetrapolar electrode system is used to overcome this problem.
However, because this system measures the impedance of the entire chest, a large part of the electrical field is concentrated in the surface tissues, and this considerably reduces the sensitivity of the method (10,11). Furthermore, Kubicek's electrodes may be burdensome and for critically ill patients when prolonged monitoring is required. The main disadvantage of this and other more sensitive methods is surgical implantation of the electrodes (10,13) A new impedance monitor, model RS- 207 EDEMA GUARD MONITOR (R. S. Medical Monitoring, Jerusalem, Israel), has been developed (15). The monitor design has also solved the problem of the drift skin-to-electrode electrical resistance and its drift during prolonged monitoring by separating ITI from skin-to-electrode electrical resistance. The result of the above mentioned actions is a value of Internal Thoracic Electrical Resistance (Impedance) - ITI. The method of ITI estimation that completely described by Rabinovich (15) Unlike the existing impedance monitors, the new monitor measures only ITI, which roughly equals lung impedance, by automatically calculating skin electrode impedance and subtracting it from TTI. According to the published data, ITI ranges from 40 to 100 ohm in individuals without CPE and, on average, decreases to 30 ohm, i.e., by30% to 75% during CPE (11-12,16-21). These results showed much higher sensitivity compared with the 1.5% changes found using TTI methods. This is an average 35- fold increase (range, 20- to 50-fold intraindividual constitutional differences) of impedance plethysmograph sensitivity compared with the method without substraction of skin electrode resistance (2-8). This monitor was succefully used for early detection of pulmonary edema however there was no any expearence on pleural fluid detection.(11,12,16-20.) The aim of the present study is to evaluate the suitability of the RS-207 in monitoring PlEf at clinical and preclinical stage. The tests will be considered successful if ITI will be low or decreased parallel to or before the appearance of clinical signs and radiograph findings compatible with PlEf, and then demonstrably increased during their resolution.
Considerations and purpose Previous study based on measurements of ITI in early diagnosis of pulmonary edema showed suitability of the RS-207.
There is no any study that deals with early diagnosis of pleural effusion by this simple nonexpencive method which can be used in ICU and ambulatory Measuring ITI, the main component of which is lung impedance, is a noninvasive and safe method. PLE will be diagnosed in accordance with well-accepted clinical signs(dyspnea, cyanosis, pulmonary rales, crepitations, arterial hypoxemia) and roentgenological criteria.
The consideration of the study : evaluation of the suitability of the RS-205 monitor in detecting the PLE at preclinical stage before the appearance of clinical signs for assessment of early treatment and then to demonstrate increased of ITI during their resolution.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Pletysmograph
Pletysmograph electrodes are applied to the thoracic wall
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* valvular heart disease
* renal failure
* infectious disease malignant diseases( all complicated by pleural effusion).
* The control group will be comprised of patients 40-90years old without pleural effusion established by chest X-ray.
40 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Michal Roll PhD,MBA
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Michal Roll PhD,MBA
Director, Research and Development
References
Explore related publications, articles, or registry entries linked to this study.
Charach G, Rubalsky O, Charach L, Rabinovich A, Argov O, Rogowski O, George J. Internal thoracic impedance - a useful method for expedient detection and convenient monitoring of pleural effusion. PLoS One. 2015 Apr 28;10(4):e0122576. doi: 10.1371/journal.pone.0122576. eCollection 2014.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
TASMC-11-CG-504-CTIL
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.