Neurovascular Non Contrast-Enhanced MR Angiography at 3T
NCT ID: NCT01566903
Last Updated: 2018-04-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
80 participants
OBSERVATIONAL
2012-06-05
2016-11-22
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
MRA is an alternative to digital substracted angiography (DSA), circumventing th use of endovascular catheterism, irradiation and injection of iodinated contrast agent. Contrast-Enhanced MRA (CE-MRA) with gadolinium injection is currently the reference standard for vascular MR exploration but still presents many limitations inherent to the injection of contrast medium. Hence, the synchronization of the acquisition with bolus contrast injection limits the improvement of spatial and temporal resolutions and requires an accurate synchronization of the acquisition with the arrival of the bolus.
Moreover, the acquisition can be repeated as required as it does not require any contrast injection.
Besides, the increase in nephrogenic systematic fibrosis clinical cases, which would be secondary to gadolinium chelates injection, in patients with chronic renal insufficiency has restricted the use of CE-MRA. More than 500 cases were described to date in the world.
Its occurrence is currently estimated around 4 % for patients in terminal chronic renal insufficiency and its mortality around 30 %.
According to the recommendations of AFSSAPS from August, 2007, two gadolinium contrast agent (Gadodiamide-OMNISCAN \*, General Electric HealthCare and Gadopentetate Dimeglumine-MAGNEVIST \*, Bayer HealthCare) are contraindicated if the glomerular filtration rate is lower than 30 ml/mn.
Non-contrast enhanced MR angiography (NCE MRA) techniques have been proposed to provide complete and non-invasive investigation of the vasculature, thus offering patients with chronic renal insufficiency, as well as pregnant or nursing women a surrogate with no side effects.
Moreover, the use of high field (3T) MR imaging offers improved signal to noise ratio. Combined with the use of phased array coils and parallel imaging, new NCE MRA sequences can achieve juxta-millimeter isotropic spatial resolution and temporal resolution of about 50 ms close to those of cerebral DSA.
These sequences allow a joint hemodynamical and morphological assessment of lesions, both at the cervical and cerebral levels, whether at diagnosis or during patient follow-up
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparative Study of Non-enhanced Versus Contrast Enhanced MR Angiography in Peripheral Arterial Disease on a 3T MR Scanner.
NCT01295554
MRI to Detect Embolism Following Angiography and Angioplasty-Stenting of the Renal Artery
NCT00027469
Clinical Use of Magnetic Resonance Perfusion Imaging to Qualitatively Assess Adequate Distal Perfusion After Endovascular Revascularization in Critical Limb Ischemia
NCT02646150
Magnetic Resonance Angiography (MRA) for the Diagnosis of Atherosclerosis
NCT00001841
Syngo NATIVE Contrast Enhanced 3D MRA on 3T Verio Magnet
NCT02065648
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Secondary objectives are:
* to compare the NCE MRA sequences with the CE MRA sequences used in the clinical routine.
* to evaluate the anatomic and hemodynamic changes observable with sequences in the follow-up of patients, particularly those treated with partial embolization or radiosurgery.
By circumventing the limitation to short bolus duration synchronization, the new dynamic sequences have the potential to achieve higher temporal resolution without compromising spatial resolution. Arteries and arteriovenous shunts may be more precisely identified and, due to a better visibility of small vessels allow a more accurate dynamic analysis.
Finally, the sequence being derived from arterial spin labeling, and differing from time of flight or phase contrast sequences, should allow for an exploration less dependent on the vascular geometry with better anatomical analysis. For example, the tendency to overestimate arterial stenoses could be reduced.
The robustness of sequences allow the non-invasive monitoring of patients including it possible to monitor the hemodynamic changes after radiosurgery or embolization.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CONTROL
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
arteriovenous malformations
No interventions assigned to this group
Arterial stenosis
No interventions assigned to this group
Post-treatment follow-up
Patient with an arteriovenous malformation for which treatment by embolization or radiosurgery is indicated
No interventions assigned to this group
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Any adult patient known or clinically suspect to present a neurovascular disease (arterial stenosis ou arteriovenous malformations), the assessment of which requires an MRA or patient having an arteriovenous malformation for which treatment by embolization or radiosurgery is indicated multidisciplinary meeting and followed in the ordinary course of this treatment
* Patient able of accepting protocol information
* Patient who received information about the protocol and had not expressed its opposition to participate
Exclusion Criteria
* Contraindication to the injection of contrast agent: pregnancy, lactation, history of allergic reaction to contrast agent injection
* Hemodynamically unstability, acute respiratory failure, a precarious condition or a need for continuous monitoring incompatible with the constraints of MR imaging
* Patient with severe kidney with Glomerular Filtration rate \< 30 ml/min
* Persons subject to major legal protection (safeguarding justice, guardianship, trusteeship), persons deprived of liberty
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Rennes University Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
jean-yves gauvrit
Role: PRINCIPAL_INVESTIGATOR
Rennes University Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Rennes University Hospital
Rennes, Brittany Region, France
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
LOC/11-19
Identifier Type: OTHER
Identifier Source: secondary_id
2011-A01258-33
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.