Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis

NCT ID: NCT00001946

Last Updated: 2008-03-04

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE1

Total Enrollment

40 participants

Study Classification

INTERVENTIONAL

Study Start Date

1999-12-31

Study Completion Date

2002-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study will evaluate ways to improve magnetic resonance angiography (MRA) for diagnosing atherosclerosis (hardening and narrowing of the arteries).

MRA is a new method for looking at arteries and veins without standard angiography, which requires inserting a catheter into a blood vessel, injecting a contrast material, and obtaining X-ray images. Current MRA techniques, however, do not depict the lumen (cavity) of small vessels well enough to accurately determine the extent of their narrowing. This study will test image processing methods with the eventual goal of improving MRA accuracy to the point that it can replace X-ray catheter angiography for diagnosing atherosclerotic disease.

Patients with atherosclerosis who have had conventional angiography at Suburban Hospital in Bethesda, MD, may be considered for this study. They will be screened with a brief history and physical examination, and those enrolled will have a MRA scan within 72 hours of their conventional angiogram. For this procedure, a catheter is placed in a vein in the patient's arm and the patient lies on a table that slides into a magnetic resonance imaging (MRI) scanner-a large donut-shaped machine with a magnetic field. Surface coils-flexible, padded antennae used to improve the quality of the pictures-are wrapped around the patient's legs. At times during the scan, the patient is asked to hold his or her breath for several seconds, and a contrast material called gadolinium is injected through the catheter in the vein. This substance enhances the images of blood flow in the vessels. The procedure generally takes about an hour and a half, although the actual imaging takes only a small part of that time.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Contrast Enhanced Magnetic Resonance Angiography (MRA) is a developing technology for the non-invasive evaluation of arterial and venous structures which does not require x-ray based catheter angiography. While dramatic progress in MRA has recently been made, there are still substantial limitations in the accuracy of MRA in grading stenoses and detecting small accessory vessels. The purpose of this study is to recruit patients with documented atherosclerotic disease as confirmed on catheter angiography performed at Suburban Hospital for evaluation with state-of-the-art MRA on MRI units, also at Suburban Hospital. We intend to test new surface coils, new pulse sequence designs, and advanced image processing algorithms in order to improve MRA accuracy to the point that a large-scale study of MRA vs. conventional angiography is possible. The goal of this pilot study is to improve MRA to the point that it can reliably replace diagnostic x-ray catheter angiography in the evaluation of patients with atherosclerotic disease.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atherosclerosis

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Primary Study Purpose

TREATMENT

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Magnetic resonance angiography

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Patient must be willing to participate in the study.

Patient must have documented atherosclerotic disease of an extracranial vessel by angiography performed within 72 hours of the MRA.

Patient must be referred by a physician who is caring for the patient and to whom the results will be provided.

Patient must be clinically stable and be judged by their physician able to tolerate lying in the MR gantry for up to 1.5 hours.

Patient must have serum Creatinine value less than 3.0mg/dl.

Must not have any contraindication for MRI including: pacemaker or other implanted electronic device; cochlear implants; metal in the eye; embedded shrapnel fragments; cerebral aneurysm clips; or medical Infusion pumps.

Must not have an allergy to Gadolinium based contrast media.

Must not have unsatisfactory performance status as judged by the referring physician such that the patient could not tolerate an MRI scan for 1.5 hours. Examples of medical conditions that would not be accepted would include unstable angina, dyspnea at rest, severe pain at rest, and severe back pain.

Must not have intercurrent illness that requires treatment that would be jeopardized by the MRA scan.

Subjects must not require sedation for MRI studies other than administered normally for a conventional angiogram.

Must not be pregnant.

Must not be nursing mothers.
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Institutes of Health Clinical Center (CC)

NIH

Sponsor Role lead

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Warren G. Magnuson Clinical Center (CC)

Bethesda, Maryland, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Prince MR, Yucel EK, Kaufman JA, Harrison DC, Geller SC. Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography. J Magn Reson Imaging. 1993 Nov-Dec;3(6):877-81. doi: 10.1002/jmri.1880030614.

Reference Type BACKGROUND
PMID: 8280977 (View on PubMed)

Prince MR. Peripheral vascular MR angiography: the time has come. Radiology. 1998 Mar;206(3):592-3. doi: 10.1148/radiology.206.3.9494471. No abstract available.

Reference Type BACKGROUND
PMID: 9494471 (View on PubMed)

Prince MR. Contrast-enhanced MR angiography: theory and optimization. Magn Reson Imaging Clin N Am. 1998 May;6(2):257-67.

Reference Type BACKGROUND
PMID: 9560485 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

00-CC-0028

Identifier Type: -

Identifier Source: secondary_id

000028

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.