Technical Development of Cardiovascular Magnetic Resonance Imaging
NCT ID: NCT00064896
Last Updated: 2017-10-30
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE1
37 participants
INTERVENTIONAL
2003-07-14
2017-10-26
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Patients 18 years of age or older who require 1) catheterization of the leg arteries for diagnosis or treatment of blocked arteries, or 2) heart catheterization for diagnosis or treatment of coronary artery disease or other heart problems may be eligible for this study. Participants will undergo one of the following procedures:
Blood Flow Measurement Using Standard Techniques and MRI
For patients with blockage in a leg artery, blood flow will be measured before and after successful catheter-based treatment (angioplasty or stenting) using standard venous occlusion plethysmography and a newer MRI technique. (Patients whose treatment is not successful will not undergo follow-up blood flow measurements in this study.) For venous occlusion plethysmography, a large pressure cuff is placed around the upper or lower legs. Thin elastic bands called a strain gauge are placed around the calves to measure blood blow to the legs. The pressure cuffs are inflated for 5 minutes, preventing blood from flowing to the legs, and are then deflated, allowing the blood to rush to the legs. A smaller cuff is inflated to a low pressure, and the strain gauge measures this maximum blood flow to the legs for 1 or 2 more minutes. For the new MRI technique, blood flow is measured while the patient is in the MRI scanner. Flow is first measured with the patient at rest. Then, the large pressure cuff is inflated for 5 minutes. The cuff is deflated and additional images are taken. Before the cuff is deflated, a dye called gadolinium contrast is injected into an arm vein to brighten the images. Patients may undergo six to eight cuff inflations on four to six different days.
Fusion of X-Ray and MRI Images of Peripheral Arteries
For patients with blockage in a leg artery Participants will undergo catheterization and MRI of the legs. Special plastic beads are taped to the leg(s) to help compare the MRI and x-ray pictures. For the catheterization procedure, x-rays of the blood vessels are taken to guide placement of the catheters. Contrast dye is injected to brighten the images of the blood vessels. These injections work well in normal and partly blocked arteries, but not in arteries that are completely blocked. For this study, patients first have an MRI scan of their legs. During the scan, gadolinium contrast dye is injected into an arm vein. Then, during the catheterization procedure, a computer aligns the MRI pictures with the x-ray pictures to see if the combined images allow the doctor to better see where to place the catheters.
Fusion of X-ray and MRI Images of the Heart
For patients undergoing heart catheterization will undergo MRI and heart catheterization. Special plastic beads are taped to the chest to help compare the MRI and x-ray pictures. Patients first have an MRI scan of their heart. During the scan, gadolinium contrast dye is injected into an arm vein. Then, during the catheterization procedure, a computer aligns the MRI pictures with the x-ray pictures to see if the combined images allow the doctor to learn more about the pattern of heart disease.
Heart rhythm, blood pressure, heart function, and breathing will be monitored during all the MRIs.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
We are developing minimally-invasive cardiovascular interventional procedures using real-time magnetic resonance imaging, also known as MR Fluoroscopy. These procedures have the advantage of excellent imaging without surgery and without radiation exposure or toxic contrast agents (dyes). Moreover, because MR Fluoroscopy can produce excellent images of soft tissue, blood, and of three-dimensional structures, it may be possible to guide minimally-invasive procedures not possible even with invasive surgery.
The goal of this protocol is to develop and test incremental technical advances in patients.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
TREATMENT
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
MRI
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Subject's age is greater than 18 years of age.
Expected to undergo, or having undergone, a clinically-indicated diagnostic or therapeutic catheterization procedure or MRI angiogram procedure.
-Known or suspected peripheral artery occlusion.
Exclusion Criteria
* Implanted cardiac pacemaker or defibrillator
* Central nervous system aneurysm clips
* Implanted neural stimulator
* Cochlear implant
* Ocular foreign body (e.g. metal shavings)
* Insulin pump
* Metal shrapnel or bullet.
When subjects can provide evidence that their implanted device is labeled compatible with MRI, exceptions to the above exclusions can be made and recorded in the note. Furthermore, the FOLLOWING SUBJECT GROUPS WILL BE EXCLUDED because of the administration of MRI CONTRAST AGENTS:
* Pregnant women (Subjects who are uncertain as to whether they are pregnant will be required to have a screening urine or blood pregnancy test) or Lactating Women.
* Subjects with hemoglobinopathies
* Subjects with renal disease (eGFR\[R\] less than 30 mL/min/1.73m(2))
Glomerular filtration rate will be estimated using the MDRD 2005 revised study formula:
eGFR (mL/min/1.73m (2)) equal 175 x (standardized Scr) (-1.154) x (age) (-0.203) x 0.742 (if the subject is female) or x 1.212 (if the subject is black)
However, if the eGFR less than 30 mL/min/1.73m(2) and gadolinium contrast exposure is thought likely to reduce the overall risk of the medically necessary interventional procedure in Specific Aim number 2, then with informed consent and the concurrence of the attending physician, the patient may be enrolled in the study. This would be documented in the medical record, and the IRB would be notified.
A patent autologous or prosthetic bypass graft that would require compression during arterial occlusion to induce reactive hyperemia. This exclusion is intended to avoid graft injury and possible thrombosis. If an old graft is known to be non-functional, from radiocontrast or MRI angiography, then this exclusion does not apply.
A patent intravascular stent in a territory that would be compressed during arterial occlusion to induce reactive hyperemia. This exclusion is intended to avoid theoretical stent crush or fracture. If the stented vessel is known to be completely occluded, from radiocontrast or MRI angiography, then this exclusion does not apply. However, occlusive cuffs may be placed above or below stent devices to avoid this theoretical complication.
Active deep vein thrombosis of the lower extremity based on clinical findings.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
National Heart, Lung, and Blood Institute (NHLBI)
NIH
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Robert J Lederman, M.D.
Role: PRINCIPAL_INVESTIGATOR
National Heart, Lung, and Blood Institute (NHLBI)
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
National Institutes of Health Clinical Center, 9000 Rockville Pike
Bethesda, Maryland, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Murphy KP, Szopinski KT, Cohan RH, Mermillod B, Ellis JH. Occurrence of adverse reactions to gadolinium-based contrast material and management of patients at increased risk: a survey of the American Society of Neuroradiology Fellowship Directors. Acad Radiol. 1999 Nov;6(11):656-64. doi: 10.1016/S1076-6332(99)80114-7.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
03-H-0250
Identifier Type: -
Identifier Source: secondary_id
030250
Identifier Type: -
Identifier Source: org_study_id