Use of the Neovasc Coronary Sinus Reducer System for the Treatment of Refractory Angina Pectoris in Patients With Ngina Class 3-4 Who Are Not Candidates for Revascularization

NCT ID: NCT01566175

Last Updated: 2022-02-02

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

100 participants

Study Classification

INTERVENTIONAL

Study Start Date

2011-08-30

Study Completion Date

2031-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to implant the Reducer in patients with the symptoms of refractory angina, that suffer from refractory angina who demonstrate reversible ischemia.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

* Interventional, Allocation: Open label, Primary Purpose: Treatment
* Diagnosis and treatment for which the device is required:Patients with advanced obstructive coronary artery disease and severe disabling refractory angina despite optimal medical therapy. No revascularization option available.
* Why this unlicensed device is chosen over a licensed device or conventional therapies for this particular patient? Patient currently treated with optimal medical therapies that include: long acting nitrates, beta blockers, and calcium channel blockers. The patient is not amendable to re-do bypass graft surgery, not amendable to percutaneous coronary intervention, as determined by recent coronary angiography.

There is no other licensed device that can effectively ameliorate refractory angina and reduce the number of angina episodes and improve quality of life.

-The current device has been used in 25 patients to date. Safety information at 6 months had been published (JACC 2007;49:1783). Extended safety and efficacy information at 3 years had been reported in March 2010 (ACC Annual Scientific conference). The device has not been associated with any procedure-related adverse events during the follow-up period.

Risks (theoretical):•Coronary sinus dissection at the time of implantation. •Coronary sinus perforation and acute cardiac tamponade requiring drainage. •Device migration and embolization. •Late coronary sinus occlusion These risk were not reported in patients who receieved the device. Benefits: •Reduce angina severity. •Improve quality of life. •Reduction in the intensity of medical therapy with decrease side effects. •Reduced incidence of hospital admissions, emergency room visits and outpatient clinic visits for refractory angina. •Improved left ventricular function, and reduced LV end diastolic pressure. These patients have poor quality of life. They are disable and unable to work or to perform basic daily activities. Cannulation of the coronary sinus presents procedural risks similar to that of pacemaker electrode insertion, a procedure which is frequently performed in Interventional cardiology. For these particular patients with poor quality of life, the offered technology can potentially make them more active, more productive, and less dependent on medication and the health system.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Refractory Angina

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Neovasc coronary sinus reducer

open label: Neovasc coronary sinus reducer

Group Type EXPERIMENTAL

Neovac coronary sinus reducer

Intervention Type DEVICE

reducer

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Neovac coronary sinus reducer

reducer

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Reducer

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* \>18 years old
* Symptomatic CAD with chronic refractory angina pectoris classified as Canadian Cardiovascular Society (CCS) grade III or IV despite attempted optimal medical therapy for thirty days prior to screening
* Non-candidate for surgical or percutaneous coronary intervention, as determined by 2 independent Professors of Internal medicine
* Reversible ischemia of the left ventricular wall demonstrated by Dobutamine Stress Echocardiography (Dobutamine ECHO; DSE), or by Thallium Spect

Exclusion Criteria

* Recent (within three months) acute coronary syndrome
* Recent (within six months) PCI or CABG
* Unstable angina (recent onset angina, crescendo angina, or rest angina with ECG changes) during the thirty days prior to screening
* De-compensated congestive heart failure or hospitalization due to CHF during the three months prior to screening
* Life threatening rhythm disorders or any rhythm disorders that would require placement of an internal defibrillator and or pacemaker
* Severe chronic obstructive pulmonary disease as indicated by a forced expiratory volume in one second that is less than 55% of the predicted value
* Severe valvular heart disease
* Patient with pacemaker or defibrillator electrode in the right atrium, right ventricle, or coronary sinus
* Patient having undergone tricuspid valve replacement or repair
* Known allergy to stainless steel or nickel
* Patient with anomalous or abnormal CS as demonstrated by angiogram. Abnormality defined as: Abnormal CS anatomy (e.g., tortuosity, aberrant branch, persistent left SVC) and/or; CS diameter at the site of implantation\> 12mm
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Shockwave Medical, Inc.

INDUSTRY

Sponsor Role collaborator

Tel-Aviv Sourasky Medical Center

OTHER_GOV

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Eli Sprecher, MD

Prof. Gad Keren

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Tel Aviv Sourasky Medical Center

Tel Aviv, , Israel

Site Status RECRUITING

Tel Aviv Medical Center

Tel Aviv, , Israel

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Israel

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Shmuel Banai, Prof.

Role: CONTACT

972-3-6973395

Gad Keren, Prof.

Role: CONTACT

972-3-6974762

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Shmuel Banai, Prof.

Role: primary

972-3-6973395

Gad Keren, Prof.

Role: backup

972-3-6974762

Shmuel Banai, Prof

Role: primary

972-3-6973395

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Neovasc Reducer

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Registry of Cardiovascular Disease Patients
NCT01759225 ENROLLING_BY_INVITATION