Silk Road Medical First in Man Study - Neuroprotection During Carotid Stenting and Angioplasty

NCT ID: NCT01264419

Last Updated: 2020-02-17

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

75 participants

Study Classification

INTERVENTIONAL

Study Start Date

2009-03-31

Study Completion Date

2012-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Cerebral embolization during carotid artery stenting (CAS) can often precipitate severe adverse neurological effects. Most major clinical studies of CAS have used distal filters for cerebral protection and have compared the neurologic complication rates with those of carotid endarterectomy (CEA). Many currently available embolic protection devices, however, have limited efficacy in capturing microembolic debris that is liberated during stenting, pre-dilatation and post-dilatation. Distal protection systems are furthermore limited by the need to cross the lesion prior to deployment. Some studies have shown a relatively high incidence of cerebral infarction even when distal protection devices are employed.

Cerebral protection with carotid flow reversal is a method that was developed by Parodi, et al., as an alternative to the use of distal protection devices. While novel in its approach, this method too has its limitations. Criado, et al., developed a derivative technique that employs carotid flow reversal prior to traversing the stenosis and can be accomplished by directly accessing carotid anatomy without the use of the transfemoral approach. Major benefits to this method include the ability to perform the procedure on patients with severe carotid tortuosity and difficult aortic arch anatomy.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Carotid artery disease is known to increase the risk of neurologic consequences such as transient ischemic attacks (TIA), ischemic stroke, or death due to the release of embolic particles in the vessels supplying the brain. Two principal treatments, carotid endarterectomy (CEA), and carotid artery stenting (CAS), are used to treat this disease. Embolic protection devices, both distal filters and occlusive devices, are employed during the CAS procedure to reduce the risk of carotid plaque embolus secondary to instrumentation during carotid intervention. Existing embolic protection devices are placed using a transfemoral approach and thus have potential for particle embolization while crossing the aortic arch, supraaortic trunk and the carotid lesion before cerebral protection is in place. Other limitations of these devices include the potential for carotid intimal injury, dissection or spasm during deployment, and release of emboli during retrieval.

Noting that carotid embolization remains the "Achilles heel" of carotid artery stenting, an alternative approach to embolic protection was developed by Juan Parodi. The system works by balloon occlusion of the common carotid artery and external carotid artery. An arteriovenous fistula is created with sheaths and catheters and provides retrograde (reverse) blood flow from the internal carotid artery (ICA) and the common carotid artery (CCA) to the femoral vein.

Embolic particles released during CAS pass retrograde through a catheter into a 180 micron filter before the blood re-enters the venous system. (Parodi, Ferreira et al. 2005) A variation of the reverse flow approach utilizing a surgical, transcervical approach to the carotid artery was developed to address challenges and risks associated with the placement and use of existing embolic protection devices. Criado et al. (2004) describe the use of flow reversal during CAS via a transcervical surgical cutdown, access and proximal occlusion of the CCA and establishment of a carotid artery - internal jugular (IJ) vein fistula. (Criado, Doblas et al. 2004).

A difference between the transfemoral-based Parodi approach and the transcervical-based Criado approach is the removal by Criado of the ECA occlusion step. In the Criado approach, the procedure is designed such that the flow is reversed in both the internal and the external carotid arteries, whereas in the Parodi procedure, flow reversal occurs only in the ICA. Another difference in the Criado system is the shorter length and larger diameter tubing afforded by the transcervical approach. The rate of flow reversal enabled by the Criado arteriovenous shunt is higher and is designed to overcome the potential for antegrade flow from the ECA to the ICA.

However, as reported by both Parodi and Criado, active aspiration is often utilized during critical periods of the procedure, to guarantee robust reversal of flow in the ICA.

Similarly in 2004, Chang, et al., reported the use of a direct transcervical approach through a 2cm incision at the base of the neck in 21 CAS patients with a 0% technical failure rate and a 0% thirty-day combined stroke or mortality rate. A similar approach of direct access to the low common carotid artery and the creation of a shunt to the internal jugular was used with carotid occlusion leading to a state of flow reversal. In some cases in this series, a balloon was placed in the external carotid artery. (Chang et al, 2004) Subsequently, Criado et al reported in the Journal of Vascular Surgery in 2004 on a series of fifty patients who underwent carotid artery stenting via this transcervical approach. Using the technique described above, flow was reversed in the ICA by occluding the CCA and establishing a carotid-jugular vein fistula. There was technical success in all 50 procedures and no strokes or deaths occurred. The procedure was tolerated by all but two (4%) of patients. Complications included major and minor carotid artery dissections, which resolved after stent placement. Two transient ischemic attacks (TIA) occurred, one in a patient in whom flow reversal was not successful, and one patient with a contralateral ICA occlusion who suffered a contralateral TIA.(Criado, Doblas et al. 2004).

Criado et al. further report in the Journal of Vascular Surgery in 2004 on a series of 10 awake patients undergoing transcervical carotid artery stenting with flow reversal. Procedural success was achieved in all 10 cases and flow reversal was well tolerated. Cerebral oxygenation during ICA flow reversal was comparable to that during CCA occlusion. ICA angioplasty balloon inflation produced a decrease in SVO2 significantly greater than that occurring during ICA flow reversal. (Criado, Doblas et al. 2004) Finally, Criado et al report on the perioperative and 3 year follow up results of 103 consecutive carotid artery stenting procedures done with a transcervical approach using carotid flow reversal for cerebral protection performed over a 28 month period in 97 patients. Technical success was achieved in 100 cases (97%). No major strokes or deaths occurred. Three awake patients (4%) did not tolerate flow reversal and complications included one ipsilateral TIA, one contralateral TIA, and two minor strokes. There were two wound complications and one major arterial complication. Mean flow reversal time was 21 minutes. At 40 months, the stent patency rate on an intention-to-treat basis was 95%, and the stroke-free survival was 91%. (Criado, Fontcuberta et al. 2007).

In 2006, Ribo and colleagues monitored transcranial doppler (TCD) as part of their standard carotid practice where 23 of 65 patients underwent transcervical carotid stenting using Criado's technique. Mean reversal time was about 15 minutes and well tolerated. TCD monitoring showed an absence of air/solid emboli during stent deployment and angioplasty confirming the presence of reverse flow. Baseline middle cerebral artery (MCA) flow by TCD of 47 cm/sec was substantially decreased with clamping of the common carotid (representing reversal of internal carotid flow). Initial mean antegrade MCA velocity of 30 cm/sec was present post clamping suggesting that there was adequate hemispheric blood flow to be clinically tolerated (Ribo et al. 2006).

Silk Road Medical has developed a system of sheaths, shunts and flow regulators, called the SRM Embolic Protection System, to apply the demonstrated benefits of the Criado and Chang approaches and improve further on ease of use and effectiveness. Silk Road Medical has provided an arteriovenous shunt with the ability to regulate from a low, baseline flow to a higher flow rate. This is accomplished by modulating the flow resistance of a shunt line which connects an arterial and a venous sheath. Because of potential patient intolerance to long periods of high reverse flow, the flow controller enables the user the set the shunt high flow only during periods of the procedure which are high risk for embolic debris (angiography, angioplasty, stent placement). This system eliminates the need for an active aspiration step, and theoretically enables the user to balance patient tolerance needs with optimal embolic protection.

The conclusion from the series of above literature is that transcervical CAS with carotid flow reversal can be accomplished with a high rate of technical success, a very low rate of major adverse events, and an excellent 3 year stroke free survival and stent patency rate. The purpose of this initial investigation is to determine if the SRM Embolic Protection System enables flow reversal of the carotid artery, is compatible with the techniques, devices and equipment used during a carotid artery stenting CAS procedure, and does not present any additional safety risks to the patient.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Carotid Artery Diseases

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Silk Road Embolic Protection System

Eligible subjects who are to receive a carotid artery stent, via transcervical access using reverse flow cerebral protection, as treatment for high-grade extracranial carotid artery disease

Group Type EXPERIMENTAL

Silk Road Embolic Protection System

Intervention Type DEVICE

System that delivers a carotid artery stent, via transcervical access using reverse flow cerebral protection, as treatment for high-grade extracranial carotid artery disease

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Silk Road Embolic Protection System

System that delivers a carotid artery stent, via transcervical access using reverse flow cerebral protection, as treatment for high-grade extracranial carotid artery disease

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subject must be \> 21 years of age.
* Subject has the ability to understand and cooperate with study procedures and agrees to return for all required follow-up visits, tests and exams.
* Subjects taking warfarin may be included if their dosage is reduced before the procedure to result in an International Normalized Ratio (INR) of 1.5 or less. Warfarin may be restarted to therapeutic dose after the procedure.
* The subject must sign a written informed consent prior to the procedure, using a form that is approved by the local medical ethics committee (EC).
* The life expectancy of the subject is at least one year.
* The subject has a lesion located in the internal carotid artery (ICA); the carotid bifurcation may be involved.
* The subject must have a minimum distance of 5 cm between the clavicle and bifurcation, as assessed by duplex Doppler ultrasound, computed axial tomographic (CT) angiography or magnetic resonance (MR) angiography.

Exclusion Criteria

* The subject was participating in another investigational trial that would interfere with the conduct or result of this study.
* The subject had dementia or a neurological illness that may confound the neurological evaluation.
* Presence of any one of the following anatomic risk factors:

* Previous radiation treatment to the neck or radical neck dissection
* Tracheostomy or tracheal stoma
* Laryngectomy
* Contralateral laryngeal nerve palsy
* Severe tandem lesions
* Inability to extend the head due to cervical arthritis or other cervical disorders
* A total occlusion of the target vessel.
* There was an existing, previously placed stent in the target artery.
* The subject had a known life-threatening allergy to the contrast media that cannot be treated.
* Subject had history of intolerance or allergic reaction to any of the study medications including aspirin, Clopidogrel bisulfate (Plavix®) or Ticlopidine (Ticlid®), heparin or Bivalrudin (Angiomax™). Subject was unable to tolerate a combination of aspirin and Clopidogrel/Ticlopidine.
* The subject had a GI bleed that would interfere with antiplatelet therapy.
* The subject had known cardiac source of potential emboli.
* Subject had a Hemoglobin (Hgb) level less than 8 gm/dL (unless on dialysis), platelet count \< 50,000/mm3, or known heparin associated thrombocytopenia.
* Subject had documented atrial fibrillation in the 90 days prior to the procedure.
* The subject had a history of bleeding diathesis or coagulopathy including thrombocytopenia or an inability to receive heparin in amounts sufficient to maintain an Activated Clot Time (ACT) at \> 250, or will refuse blood transfusion.
* The subject had atherosclerotic disease involving in the ipsilateral common carotid artery that precluded safe placement of the arterial sheath.
* The subject has other abnormal angiographic findings that indicate the subject is at risk for a stroke due to a problem other than that of the target lesion, such as: ipsilateral arterial stenosis greater in severity than the target lesion, cerebral aneurysm, or arteriovenous malformation of the cerebral vasculature.
* There is evidence of a carotid artery dissection prior to the initiation of the procedure.
* There is an angiographically visible thrombus.
* There is any condition that precludes proper angiographic assessment or makes percutaneous arterial access unsafe, e.g. morbid obesity, sustained systolic blood pressure \> 180 mm Hg, tortuosity, occlusive disease, vessel anatomy, aortic arch anatomy, or cerebral protective system.
* Occlusion (TIMI 0 flow), or string sign of the ipsilateral common or internal carotid artery.
* There is evidence of bilateral carotid stenosis that would require intervention within 30 days of procedure.
* There is evidence of a stroke within the previous 30 days of the procedure.
* There is a planned treatment of a non-target lesion within 30 days post procedure.
* There is a history of intracranial hemorrhage within the previous 3 months, including hemorrhagic transformation of an ischemic stroke.
* There is a history of an ipsilateral stroke with fluctuating neurologic symptoms within one year of the procedure.
* Female subjects who are pregnant or may become pregnant.
Minimum Eligible Age

21 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Silk Road Medical

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Sumaira Macdonald, MD, PhD

Role: STUDY_CHAIR

Chief Medical Officer

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Augusta-Krankenhaus

Düsseldorf, , Germany

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Germany

References

Explore related publications, articles, or registry entries linked to this study.

Pinter L, Ribo M, Loh C, Lane B, Roberts T, Chou TM, Kolvenbach RR. Safety and feasibility of a novel transcervical access neuroprotection system for carotid artery stenting in the PROOF Study. J Vasc Surg. 2011 Nov;54(5):1317-23. doi: 10.1016/j.jvs.2011.04.040. Epub 2011 Jun 12.

Reference Type BACKGROUND
PMID: 21658889 (View on PubMed)

Alpaslan A, Wintermark M, Pinter L, Macdonald S, Ruedy R, Kolvenbach R. Transcarotid Artery Revascularization With Flow Reversal. J Endovasc Ther. 2017 Apr;24(2):265-270. doi: 10.1177/1526602817693607. Epub 2017 Feb 17.

Reference Type RESULT
PMID: 28335706 (View on PubMed)

Related Links

Access external resources that provide additional context or updates about the study.

https://www.ncbi.nlm.nih.gov/pubmed/28335706

Transcarotid Artery Revascularization With Flow Reversal: The PROOF Study

https://www.ncbi.nlm.nih.gov/pubmed/21658889

Safety and feasibility of a novel transcervical access neuroprotection system for carotid artery stenting in the PROOF Study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

SRM-2008-01

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.