IRB-HSR# 14296 The Use of the Intrathoracic Pressure Regulator (ITPR) to Improve Systemic Blood Pressure in Patient Undergoing CABG Surgery

NCT ID: NCT01205594

Last Updated: 2011-08-10

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE2

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2009-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Briefly, after the induction of anesthesia and the placement of TEE, hemodynamic variables (pulmonary and systemic blood pressure, central and pulmonary venous pressure, cardiac output, calculated SVR, etc.) will be collected. In addition, left ventricular performance (including estimates of LVEDV, LVESV, EF, FAC, etc.) will be assessed using TEE. Once these baseline data are recorded, the ITPR will be inserted in the anesthesia circuit and activated to provide -9 mmHg ETP. After the ITPR has been active for at least two minutes, the same hemodynamic and TEE data obtained above will be gathered. After the data is recorded, the ITPR will be disconnected and no further interventions will be made. In addition to the hemodynamic and echocardiographic data described above, an arterial blood gas will be obtained from the pre-existing radial artery catheter during the on- and off- states.

Finally, the TEE examination will be recorded on videotape or DVD. A second echocardiographer, blinded to patient and ITPR status will review each echocardiogram and assess left ventricular performance. In addition to the data derived at the time of testing, the second echocardiographer will assess, if possible, changes in EF using Simpson's method of disks is used to calculate the LV volume.

This is a proof of concept/feasibility study designed to test the primary hypothesis that use of the ITPR will result in increased systemic blood pressure and cardiac output in patients undergoing CABG surgery. The effect of the ITPR on other secondary indicators of cardiac performance will also be examined. These include but are not limited to left ventricular end diastolic volume (LVEDV), ejection fraction (EF), left ventricular end systolic volume (LVESV), and fractional area change (FAC) as assessed by echocardiography, pulmonary artery pressure, and calculated systemic vascular resistance (SVR).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The ITPR is an FDA-approved device intended to increase circulation and blood pressure in hypovolemic and cardiogenic shock. The device is inserted within a standard respiratory circuit between the patient and the ventilator. It functions by decreasing intrathoracic pressure during the expiratory phase to subatmospheric levels after each positive pressure ventilation. The decrease in intrathoracic pressure creates a vacuum within the thorax relative to the rest of the body thereby enhancing blood return to the heart and consequently increasing cardiac output and blood pressure. Activation of the device is also accompanied by a decrease in SVR. The end result is a device that simultaneously improves cardiac output by increasing LVEDP/LVEDV and decreasing SVR while increasing coronary perfusion pressure by increasing blood pressure and decreasing LVESP/LVESV.1-8

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Artery Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

SINGLE_GROUP

Primary Study Purpose

HEALTH_SERVICES_RESEARCH

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

ITPR device

the ITPR will be inserted in the anesthesia circuit and activated to provide -10 mmHg ETP.

Group Type EXPERIMENTAL

ITPR

Intervention Type DEVICE

the ITPR will be inserted in the anesthesia circuit and activated to provide -10 mmHg ETP.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

ITPR

the ITPR will be inserted in the anesthesia circuit and activated to provide -10 mmHg ETP.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 1\. patients presenting for elective CABG with planned intraoperative TEE 2. age 18 years of age and older 3. informed consent has been obtained

Exclusion Criteria

* 1\. Patients with planned valve surgery (valve or CABG + valve) 2. patients with a contraindication to transesophageal echocardiography (TEE); including patients with extensive esophageal or gastric disease. Relative contraindications include esophageal varices, Barrett's esophagus, Zenker's diverticulum, and postradiation therapy of the esophageal area.

3\. patients requiring IABP or VAD pre-operatively 4. emergent CABG 5. pneumothorax 6. hemothorax 7. uncontrolled bleeding 8. uncontrolled hypertension defined as SBP \> 180 mmHg at the time of surgery
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Virginia

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

University of Virginia Anesthesiology

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Edward C Nemergut, MD

Role: PRINCIPAL_INVESTIGATOR

University of Virginia Anesthesiology

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Virginia Health System

Charlottesville, Virginia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Lurie KG, Zielinski TM, McKnite SH, Idris AH, Yannopoulos D, Raedler CM, Sigurdsson G, Benditt DG, Voelckel WG. Treatment of hypotension in pigs with an inspiratory impedance threshold device: a feasibility study. Crit Care Med. 2004 Jul;32(7):1555-62. doi: 10.1097/01.ccm.0000131207.29081.a2.

Reference Type BACKGROUND
PMID: 15241102 (View on PubMed)

Lurie KG, Zielinski T, McKnite S, Aufderheide T, Voelckel W. Use of an inspiratory impedance valve improves neurologically intact survival in a porcine model of ventricular fibrillation. Circulation. 2002 Jan 1;105(1):124-9. doi: 10.1161/hc0102.101391.

Reference Type BACKGROUND
PMID: 11772887 (View on PubMed)

Lurie KG, Voelckel WG, Zielinski T, McKnite S, Lindstrom P, Peterson C, Wenzel V, Lindner KH, Samniah N, Benditt D. Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest. Anesth Analg. 2001 Sep;93(3):649-55. doi: 10.1097/00000539-200109000-00024.

Reference Type BACKGROUND
PMID: 11524335 (View on PubMed)

Lurie KG, Mulligan KA, McKnite S, Detloff B, Lindstrom P, Lindner KH. Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Chest. 1998 Apr;113(4):1084-90. doi: 10.1378/chest.113.4.1084.

Reference Type BACKGROUND
PMID: 9554651 (View on PubMed)

Yannopoulos D, McKnite S, Metzger A, Lurie KG. Intrathoracic pressure regulation improves 24-hour survival in a porcine model of hypovolemic shock. Anesth Analg. 2007 Jan;104(1):157-62. doi: 10.1213/01.ane.0000249047.80184.5a.

Reference Type BACKGROUND
PMID: 17179262 (View on PubMed)

Yannopoulos D, McKnite SH, Metzger A, Lurie KG. Intrathoracic pressure regulation for intracranial pressure management in normovolemic and hypovolemic pigs. Crit Care Med. 2006 Dec;34(12 Suppl):S495-500. doi: 10.1097/01.CCM.0000246082.10422.7E.

Reference Type BACKGROUND
PMID: 17114984 (View on PubMed)

Yannopoulos D, Metzger A, McKnite S, Nadkarni V, Aufderheide TP, Idris A, Dries D, Benditt DG, Lurie KG. Intrathoracic pressure regulation improves vital organ perfusion pressures in normovolemic and hypovolemic pigs. Resuscitation. 2006 Sep;70(3):445-53. doi: 10.1016/j.resuscitation.2006.02.005. Epub 2006 Aug 9.

Reference Type BACKGROUND
PMID: 16901611 (View on PubMed)

Yannopoulos D, Nadkarni VM, McKnite SH, Rao A, Kruger K, Metzger A, Benditt DG, Lurie KG. Intrathoracic pressure regulator during continuous-chest-compression advanced cardiac resuscitation improves vital organ perfusion pressures in a porcine model of cardiac arrest. Circulation. 2005 Aug 9;112(6):803-11. doi: 10.1161/CIRCULATIONAHA.105.541508. Epub 2005 Aug 1.

Reference Type BACKGROUND
PMID: 16061732 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

14296

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

CNAP in Heart Surgery