Prevention of Severe Hypoglycaemia With Hypo-Safe Hypoglycaemia Alarm Device
NCT ID: NCT01178476
Last Updated: 2014-03-10
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
NA
INTERVENTIONAL
2009-11-30
2011-03-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Neuroglycopenic hypoglycaemia in insulin-treated diabetic patients is associated with characteristic changes in EEG with a decrease in alpha activity and an increase in delta and theta activity. We have recently demonstrated that hypoglycaemia-associated EEG-changes can be recorded from subcutaneously placed electrodes using an automated mathematical algorithm based on non-linear spectral analysis. Experimental findings hold promises that an alarm, given at the time of EEG-changes, can help the patients to avoid severe hypoglycaemia by ingestion of carbohydrate.
This is the first larger scale trial testing the clinical applicability of a hypoglycaemia-alarm based on real-time analysis of EEG-signals.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Using Glucose Sensors to Prevent Hypoglycemia
NCT00554281
Primary Care Clinicians' Responses to a Hypoglycemia Risk Calculator for Diabetes Mellitus in Ambulatory Care
NCT04177147
Hypoglycemia Prevention in High-Risk Type 2 Diabetes Patients
NCT06746714
The Effect of Hypoglycaemia on Brain Lactate Accumulation and Cerebral Blood Flow
NCT02146404
Prevention of Hypoglycaemia by Oral 40% Destrogel
NCT04185766
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Several studies have evaluated the potential use of continuous glucose monitoring system (CGMS) as hypoglycaemia alarms but so far failed to show reduction in the frequency of severe hypoglycaemia (8;9). Although the technology is continuously being improved it is still associated with a number of problems (10). The technique is rather imprecise, particularly in the lower range of glucose measurements, and only about 33% of hypoglycemic events were detected in a larger clinical trial (11). The accuracy of the reading is reduced when rapid changes in blood glucose occur (12). There is a significant and variable delay from the change in blood glucose to the change in the interstitial compartment ranging from 4 - 10 minutes (13) and the catheters are rather costly and must be replaced every 72 hours.
The EEG signal reflects the functional state and metabolism of the brain. The brain is almost totally dependent on a continuous supply of glucose, and when the glucose level is lower than the metabolic requirements of the brain, its function deteriorates. Neuroglycopenic hypoglycaemia in insulin-treated diabetic patients is associated with characteristic changes in EEG with a decrease in alpha activity and an increase in delta and theta activity (14-17). These changes are clearly seen at blood glucose \~2.0mmol/l (14;15) preceding the development of severe cognitive dysfunction (18). We have recently demonstrated that hypoglycaemia-associated EEG-changes can be recorded from subcutaneously placed electrodes using an automated mathematical algorithm based on non-linear spectral analysis and that EEG-changes above a predefined threshold can be demonstrated more than 10 minutes before development of severe hypoglycaemia in the majority of the patients (19). We found a very low rate of false alarms and no adverse reactions related to implantation of the electrodes. We have subsequently performed a number of studies with real-time alarms type 1 diabetes patients exposed to insulin induced hypoglycaemia. In these studies the patients were instructed to ingest carbohydrates when he/she heard the alarm sound. In three out of four cases the patients were able to do so, while a fourth patient did not spontaneously ingest the meal although, he was fully conscious and not clinically affect by the hypoglycaemia. These findings hold promises that an alarm, given at the time of EEG-changes, can help the patients to avoid severe hypoglycaemia by ingestion of carbohydrate.
For clinical applicability the device should be able to distinguish hypoglycaemia-induced EEG changes from noise, artefacts and physiological variations in the EEG including the low-frequency waves seen during sleep, with high sensitivity and specificity using a mathematical algorithm that classifies the EEG in real-time. There should be a "time-window" between hypoglycaemia-induced EEG changes and severe cognitive impairment. The device should be fully compatible with normal everyday activities. Thus, the device should be small, fully biocompatible and implantable, and the monitoring and processing unit should be small and have sufficient battery power.
This is the first larger scale trial testing the clinical applicability of a hypoglycaemia-alarm based on real-time analysis of EEG-signals.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Hyposafe Hypoglycemia alarm device
EEG based hypoglycemia detection
Hyposafe Hypoglycaemia alarm device
An EEG based hypoglycemia alarm is tested against standard glucose measurement on the risk of severe hypoglycemia
Regular glucose control
Regular glucose control group
Hyposafe Hypoglycaemia alarm device
An EEG based hypoglycemia alarm is tested against standard glucose measurement on the risk of severe hypoglycemia
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Hyposafe Hypoglycaemia alarm device
An EEG based hypoglycemia alarm is tested against standard glucose measurement on the risk of severe hypoglycemia
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age 18-70 years
* Impaired awareness of hypoglycaemia as defined by
* A score of ≥4 on the Gold-scale (Appendix 8) or
* Two or more occasions of severe hypoglycaemia (need of help from third person) within the past 12 month
* Multiple injection insulin therapy or continuous insulin injection therapy
* For female participants: Not pregnant and, if child bearing potential, usage of reliable anti-contraceptive method during the study period
Exclusion Criteria
* History of myocardial infarction
* Cardiac arrhythmia
* Previous stroke or cerebral haemorrhage and any other structural cerebral disease
* Active cancer or cancer diagnosis within the past five years
* Uremia defined as s-creatinine above 3 times upper reference value
* Liver disease defined as s-ALAT above 3 times upper reference interval
* Inability to understand the informed consent
* Epilepsy
* Use of antiepileptic drugs for any purposes
* Clinical important hearing impairment
* Use of active implantable medical device including
* Pacemaker and ICD-unit
* Cochlear implant
* Use of following drugs
* Chemotherapeutic drugs of any kind
* Methotrexate
* Third generation antipsychotic drugs (aripiprazole, quetiapine, clozapine, ziprasidone, paliperidone, risperidone, sertindole, amisulpride, olanzapine
* Abuse of alcohol (defined as consumption of \> 250g alcohol (in Danish: 21 "genstande") per week or abuse of any other neuroactive substances
* Infection at the site of device-implantation
* Any hemorrhagic disease
* Diving (snorkel diving allowed) or parachute jumping
* Patients that are judged incapable of understanding the patient information or who are not capable of carrying through the investigation
18 Years
70 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
UNEEG Medical A/S
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Hypo-Safe A/S
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Birger Thorsteinsson, MD.
Role: PRINCIPAL_INVESTIGATOR
Medical Department, Hillerød Sygehus
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hillerød Sygehus
Hillerød, , Denmark
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Hyposafe-hypo-02
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.