Endotrol-tracheal Tube Assisted Endotracheal Intubation During Video Laryngoscopy
NCT ID: NCT01099969
Last Updated: 2018-06-04
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
60 participants
INTERVENTIONAL
2010-03-31
2012-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
McGRATH MAC Video Laryngoscope
NCT02250521
Does the Use of the GlideRite® Endotracheal Tube in Combination With the I-gel® Improve Intubation Success Rate?
NCT01265862
Comparison of Simultaneous Endotracheal Tube Insertion With GlideScope Use
NCT02787629
Comparison of GlideScope-Specific Rigid Stylet to Standard Malleable Stylet for GlideScope Intubation by Novice Operators
NCT00884754
Macintosh Versus GlideScope Versus C-MAC for Double Lumen Endotracheal Intubation
NCT05091281
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
It should be noted that several reports have been published describing trauma to the upper airway (anterior tonsillar pillar, soft palate) during intubation with video laryngoscopes. Recently, several reports using endoflex tube (which is similar to the endotrol tube) showed that there is considerable usefulness in normal direct laryngoscopy and video laryngoscopy (using glidescope) as well. The purpose of this study is to compare the safety and efficacy of Endotrol Tube (Covidien, Colorado, USA) compared to the conventional endotracheal tube in conjunction with the GlideRite stylet during videolaryngoscopy assisted endotracheal intubation.
INSTRUMENTS:
McGrath Video Laryngoscope (MVL) - A video-based system for tracheal intubation that utilizes a video camera embedded into a "camera stick". The resulting video image is displayed on a small color Liquid Crystal Display (LCD) attached to the top of the handle of the device, which can be adjusted to obtain the best view. The unit is powered with a single easily-replaced AA battery and features a single electronic control: an on/off switch located on the top of the unit. The device is available with an adjustable curved MAC blade (sizes 3 to 5). Also,the device features a sterile disposable transparent blade sheath preventing cross infection.
GlideScope Video Laryngoscope (GVL)- The GlideScope was commercially introduced in 2001. The 1- piece handle and blade is made of medical- grade plastic. It has a vertical profile of 14.5 mm, a midblade bend of 50-60 degrees, and a video camera with a light-emitting diode housed toward the distal end of the blade. The image captured by the camera is transferred by the attached cable to a color liquid crystal display (LCD). A heating element covers the camera lens and ensures effective antifogging after the device has been turned on for 15- 30 seconds. The blades can be sterilized and reused, and are available in 3 sizes: large (adult), midsize (pediatric), and small (neonatal). As the image is transferred to the LCD display, anesthesiologists are able to view key anatomical landmarks at the earliest possible time, facilitating navigation. Also, in cases requiring external laryngeal manipulation, the assistant can see the effect of the maneuver on the monitor simultaneously with the anesthesiologist for quicker, more efficient intubation. Endotrol Tracheal Tube (ETT) (Covidien, Colorado, USA) - A sterile, single lumen, disposable ET with a built- in flexing mechanism with a standard 15 mm connector. The tube provides directional tip control via an operator- activated ring loop and incorporates a self- sealing valve with attached pilot balloon. The ETT is specifically designed for use in cases where difficult intubation can be aided with directional tip control. Due to the Hi-Lo cuff design, the ETT is acceptable for oral/nasal intubation of the trachea for anesthesia and in cases where the intubation duration is expected to be more than 24 hours or unpredictable. The special way to hold the ETT is to place the thumb of the right hand against the end of the 15 mm connector and the index finger in the ring loop. Pulling on the ring loop causes the tip to turn anteriorly towards the tracheal opening.
METHODOLOGY:
A. General Study Design- The study will include a total of 60 patients. Patients will be randomized into 2 groups and 2 subgroups in each group, through a computer generated randomization schedule.
Patients in group A (N= 30) will be intubated using MVL and patients in group B (N= 30) will be intubated using GVL. Patients in each group will be divided into 2 subgroups.
Group A (N= 30) - Subgroup A1 (N=15) - Patients will be intubated using Endotrol Tracheal Tube without stylet (Covidien, Colorado, USA). Subgroup A2 (N= 15) - Patients will be intubated using styletted endotracheal tube the Gliderite (Teleflex Medical, Hudson RCI/ Sheridan/ HBT). Group B (N= 30) - Subgroup B1 (N=15) - Patients will be intubated using Endotrol Tracheal Tube without stylet (Covidien, Colorado, USA).
. Subgroup B2 (N= 15) - Patients will be intubated using styletted endotracheal tube the Gliderite (Teleflex Medical, Hudson RCI/ Sheridan/ HBT). In the operating room, standard monitoring devices will be applied including a pulse oximeter, 3 lead (at least), ECG and blood pressure cuff; the latter could be invasive or non-invasive depending on the nature of the surgery. Baseline measures of BP, pulse, oxygen saturation, and CO2, will be made. The time will be noted before any sedation or anesthesia is administered. Vital signs will be recorded every minute from the time that induction of anesthesia is begun until five minutes after the patient has been intubated, and then at five-minute intervals thereafter for fifteen minutes. General anesthesia will be induced by bolus administration of propofol (2mg/kg) and fentanyl (1mcg/kg), and maintained with an inhalational agent. Rocuronium (0.6 mg/kg) will be administered to provide muscle relaxation and a mixture of sevoflurane or isoflurane and nitrous oxide will be utilized for maintenance of anesthesia once the ability to mask ventilate is confirmed. The lungs will be mechanically ventilated with a semi-closed circle system to maintain an end-tidal CO2 near 35 mmHg. Patients' lungs will be ventilated via anesthesia mask 100% oxygen until the patient is completely relaxed. All investigators will be trained based on manufacturer recommendations and each resident will perform at least 3 intubations with McGrath laryngoscope and 3 intubations with Cobalt GlideScope (total of 6 intubations) prior to enlisting any patients for the study. The CA-2 and CA-3 residents will be performing the intubations. The external neck pressure may be applied by an assistant in an attempt to improve exposure of the larynx. The ease of intubation will be recorded in terms of the number of attempts (measured as either the reinsertion of the blade or endotracheal tube) and the intubation time (time the laryngoscope blade enters the mouth until 1st capnograph breath) will be recorded. If more than 2 attempts were needed, a third attempt can be made with the device used in the other group. If still unsuccessful, the direct laryngoscopy/ flexible fibreoptic laryngoscopy will be performed to intubate the trachea and the case will be deemed a failure. The subjective level of difficulty (from 0 = Extremely Easy to 5 = Extremely Difficult) in the performance of intubation will also be recorded. An alternative technique will be used in case the intubation fails. 1. Use of the Glideride stylet if using an Endotrol tracheal tube, if the Endotrol tracheal tube is not able to get towards the cords. 2. Use of a regular stylet instead of the Glideride especially with McGrath if Glideride not able to help with intubation 3. Use of macintosh or miller appropriate blade with styletted or Endotrol tube if intubation with videolaryngoscope is difficult 4. Use of LMA or similar device in case intubation is difficult with any of the previous devices and application of a difficult airway protocol. B. Measurements- We will record morphometric characteristics of all patients. The quality of the airway will be evaluated using the Mallampati and Wilson scoring system, thyromental scoring system of Patil, interincisor gap distance, neck mobility and sternomental distance.
Additionally, the anesthesiologist will provide a personal, subjective opinion of a possible difficult intubation. Intubation: We will measure the time and number of attempts required for successful endotracheal intubation in each group. An attempt is defined as an attempt at placement of an ET through the glottic opening and into the trachea. Removal/reinsertion of the laryngoscope or the switching of the laryngoscopist will constitute as a new attempt. The subjective level of difficulty (0-5) in the performance of intubation will also be recorded. Once an optimal positional has been confirmed, position of the ET will not be further altered. Degree of irritation: Following intubation in either group, the appearance of oropharynx, pharynx, epiglottis, and arytenoids will be checked. The presence of abrasions, bleeding, redness, perforation or other signs of tissue or dental injury will be recorded.
SUBJECTS:
The subjects will be adult surgical candidates age 18-80, ASA I- III, presenting for elective surgery who require general anesthesia. Patients will be chosen if it is determined that endotracheal intubation is required. Patients will be excluded if they are considered so difficult (i.e. Mallampatti IV, \< 2 FB or 4 cm mouth opening), that an awake fibreoptic intubation should be performed. ASA IV and V patients will also be excluded.
RECRUITMENT METHODS/ INFORMED CONSENT:
Physician investigators will interview all potential subjects to determine if subjects are suitable for the study. Both English and Spanish speaking subjects will be enrolled for the study. Written consent will be obtained by an anesthesiology resident or research assistant.
PROCEDURES TO MAINTAIN CONFIDENTIALITY:
All information recorded on the anesthetic records will be kept strictly confidential and all data will be kept in a data logbook locked in the office of the principal investigator. We will record patients only by study code number.
DATA ANALYSIS:
Data will be compared using two- tailed paired t- tests, repeated measures of ANOVA, or Fisher Exact test, as appropriate. Results will be presented as means ± SD. P \< 0.05 will be considered as statistically significant.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Glidescope with non-styletted Endotrol ETT
The patients in this arm will be intubated using a Glidescope videolaryngoscope with non-styletted Endotrol endotracheal tube (ETT).
Non-styletted Endotrol endotracheal tube (ETT)
Glidescope videolaryngoscope
Glidescope with styletted regular ETT
The patientsin this arm will be intubated using the glidescope videolaryngoscope and regular endotracheal tube (ETT) with gliderite stylet.
Regular endotracheal tube (ETT) with Gliderite stylet
Glidescope videolaryngoscope
McGrath with non-styletted Endotrol ETT
The patients in this arm will be intubated using McGrath videolaryngoscope and non-styletted Endotrol endotracheal tube (ETT).
Non-styletted Endotrol endotracheal tube (ETT)
McGrath videolaryngoscope
McGrath with with styletted regular ETT
The patients receiving this arm will be intubation using McGrath videolaryngoscope and regular endotracheal tube (ETT) with Gliderite stylet.
Regular endotracheal tube (ETT) with Gliderite stylet
McGrath videolaryngoscope
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Non-styletted Endotrol endotracheal tube (ETT)
Regular endotracheal tube (ETT) with Gliderite stylet
Glidescope videolaryngoscope
McGrath videolaryngoscope
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* ASA: I-III
* Mallampati: I-III
* Mouthopening: 2 FB or \< 4 cm
Exclusion Criteria
* ASA: IV
* Mallampati: IV
* Mouthopening \< 2 FB 4cm
* No risk for aspiration
* No respiratory infection in past 10 days
18 Years
80 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
The University of Texas Health Science Center, Houston
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Davide Cattano
Associate Professor - Anesthesiology
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Davide Cattano, M.D.,PhD
Role: PRINCIPAL_INVESTIGATOR
The University of Texas Medical School at Houston
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Memorial Hermann Hospital
Houston, Texas, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
HSC-MS-09-0456
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.