Comparison of Flex-It Stylet to Malleable Stylet for GlideScope Intubation: A Randomized Controlled Trial
NCT ID: NCT00771628
Last Updated: 2009-07-14
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
80 participants
INTERVENTIONAL
2008-01-31
2008-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The null hypothesis is that there will be no difference.
The GlideScope video laryngoscope (Verathon) is a widely used intubating device that uses a high-resolution camera embedded into a plastic laryngoscope blade. An LED provides illumination. The GlideScope often provides a good laryngoscopic view, but passing the endotracheal tube (ETT) through the vocal cords is sometimes difficult. Because of the 60 degree anterior curvature of the GlideScope's blade, ETT's must have stylets inserted so that the ETT distal tip can be positioned anteriorly. Various authors have recommended different angles of the ETT to optimally place it into the trachea, including matching the GlideScope's 60 degree angle, or configuring the ETT with a 90 degree bend. Previous studies demonstrated that 90 degree sharp bend was both faster and subjectively easier in a heterogeneous group of intubators. With the introduction of the Flex-It stylet by Parker Medical, the question arises as to the the best configuration of stylet for the ETT. Therefore, this prospective, randomized, single-blinded trial is proposed.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
A Comparison of the Flex-it® to the GlideRite® Stylet for GlideScope® in Simulated Difficult Intubations.
NCT02177240
Comparison of GlideScope Specific Stylet to Malleable Stylet for GlideScope Intubation
NCT00434720
Comparison of GlideScope-Specific Rigid Stylet to Standard Malleable Stylet for GlideScope Intubation by Novice Operators
NCT00884754
Examining the Ease of Intubation Using the Parker Flex-Tip® or a Standard Endotracheal Tube
NCT01263873
Comparison of Parker Flex-Tip Endotracheal Tube to Standard Endotracheal Tube
NCT01095861
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
* at the top will be the randomization group (A, B) and a text description of the endotracheal tube angle and stylet (i.e. "90 degrees - malleable stylet")
* in the body of the piece of paper will be a template that shows the exact shape into which the tube must be bent, including where the distal and proximal ends are, the angle of curvature that must be followed, and the location along the length of the tube at which to create this angle. The angle and location will be the same for both males and females.
There are three distinct anesthesia providers involved in the conduct of this study, as follows:
1. "operator" - person performing the intubation
2. "timer" - person timing the outcome (one of the co-investigators)
3. "shaper" - person who ensures that the angle and stylet of the tube matches the group to which the patient was allocated
Because the person intubating must be blind up until the time at which the tube is to be used, the unopened envelope will be taken to a third anesthesia provider, who will prepare the ETT with stylet in an area that is not visible to the person performing the intubation or to the person timing the intubation. The person performing the intubation will specify what size of tube to be prepared. This will most commonly be 7.5 mm internal diameter (ID) for a female and 8.0 ID for males, but the operator is free to use whatever size they feel is appropriate. The tube size selection will take place before unblinding so the group allocation cannot affect the decision of tube size.
The tubes will all be cut at the 27 cm marking. "Group A" ETT's will be shaped with the aid of a standard malleable stylet (Rusch 14 Fr) that has been lubricated with single-use water-soluble lubricant. "Group B" ETT's will be instrumented with the Flex-It Stylet, with identical lubricant. The prepared tube will then be concealed under a standard green OR towel and brought to the operating room (OR). This tube will be placed close to the patient's head so that it is readily accessible.
Data Collection
In the OR, the GlideScope will be turned on at least 60 seconds before use so that the lens can warm-up to prevent fogging. The patient will be cared for in the usual fashion with respect to monitoring and induction of general anesthesia. To ensure adequate pre-oxygenation, the patient's end-tidal oxygen must be ≥ 70%. Muscle relaxation will be used, and the agent used is at the discretion of the operator. After induction of anesthesia, bag-mask ventilation will be used in the usual fashion until the operator decides to proceed to laryngoscopy with the GlideScope. The operator will remain blinded to the group allocation until after the laryngoscopic view has been obtained with the GlideScope, where upon he will be handed the endotracheal tube.
The timer (who cannot see the tube under the green towel) will watch the operator until the GlideScope is inserted into the patient's mouth, start the timer, and then turn 180º to face the anesthetic monitor. The timer will not be able to see the ETT, stylet, or curvature because he will be facing the monitor screen.
Timing will continue until end-tidal CO2 of at least 30 mmHg is seen on the anesthesia monitor, at which point the data collection form will be filled out, and the study protocol will be finished. (The time to intubation will be recorded to the nearest tenth of a second.) If the operator fails to intubate within 3 attempts or 150 seconds, the intubation will be noted as a failure, and the ultimately successful means of securing the airway will be recorded.
The definition of an "attempt" for the purposes of this clinical trial are as follows:
1. anytime the GlideScope blade is removed from the patients mouth and then re-inserted
2. anytime the endotracheal tube is re-shaped (regardless of whether or not the GlideScope is actually removed from the patient's mouth
3. if substantial adjustments are made to the patient's position (such as head position, neck flexion, or neck extension). Small movements that would occur in the normal process of intubation would not count as "substantial".
If oxygen desaturation (as recorded by pulse oximetry) below 95% occurs, then the patient will be ventilated in the usual fashion to ensure oxygenation, and re-attempting intubation using the GlideScope may proceed, but the timing will continue, and the same limits to successful intubation (within 3 attempts or total of 150s) will apply. Between attempts, the tube may be re-shaped by the operator if the operator feels that another curvature would be preferred.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Flex-It Stylet
Patients will be intubated using the GlideScope with an ETT fitted with a Flex-It stylet.
Flex-It Stylet
Patients will be intubated using the GlideScope with an ETT fitted with a Flex-It stylet.
2 Malleable
Standard malleable stylet
Patients will be intubated using the GlideScope with an ETT fitted with a standard malleable stylet.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Flex-It Stylet
Patients will be intubated using the GlideScope with an ETT fitted with a Flex-It stylet.
Standard malleable stylet
Patients will be intubated using the GlideScope with an ETT fitted with a standard malleable stylet.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. ETT is indicated for the procedure in the opinion of the attending anesthesiologist.
3. Any operator who has performed ≥ 10 GlideScope intubations.
Exclusion Criteria
2. \* Patient with known cervical spine abnormalities.
3. \* Any patients with known or probable difficult airways (this rare occurrence is unlikely to be evenly distributed between the groups and could skew the data).
4. Any patient requiring rapid sequence induction.
18 Years
75 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
London Health Sciences Centre
OTHER
Unity Health Toronto
OTHER
London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
University of Western Ontario
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Timothy P Turkstra, MD
Role: PRINCIPAL_INVESTIGATOR
Western University, Canada
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
London Health Sciences Center
London, Ontario, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Turkstra TP, Jones PM, Ower KM, Gros ML. The Flex-It stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope. Anesth Analg. 2009 Dec;109(6):1856-9. doi: 10.1213/ANE.0b013e3181bc116a.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
13949
Identifier Type: -
Identifier Source: secondary_id
R-08-111
Identifier Type: -
Identifier Source: org_study_id
More Related Trials