Closed Loop Isoflurane Administration With Bispectral Index in Open Heart Surgery

NCT ID: NCT01069562

Last Updated: 2011-02-21

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

40 participants

Study Classification

INTERVENTIONAL

Study Start Date

2009-01-31

Study Completion Date

2010-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

With the advancement in microprocessor technology and better understanding of pharmacodynamics and pharmacokinetics of anaesthetic agents, computer facilitated closed loop control of anaesthesia using propofol has been shown to be accurate with better performance than manual control. Literature on computer controlled administration of inhalational anaesthetics is few, as it requires the computer to control the dial setting on the vapouriser. The investigators intend to compare the computer controlled closed loop administration of isoflurane by infusing it into the anaesthetic circuit with conventional vaporiser control in elective open heart surgery.

40 patients (ASA (American Society of Anesthesiology) class II-IV; 18- 65 years) undergoing elective cardiac surgery requiring cardiopulmonary bypass (CPB) will be randomly divided into manual or closed loop groups. Propofol will be used for induction of anaesthesia in both groups followed by isoflurane for maintenance. In the manual group, isoflurane will be administered through the Tech 7 vapouriser during pre and post CPB periods to target bispectral index (BIS) of 50. In closed loop group, isoflurane will be administered using infusion of liquid isoflurane into expiratory limb of the closed circuit. This rate of infusion though a conventional syringe pump will be controlled by algorithm termed 'Improvised Anaesthetic Agent Delivery System' (IAADS) to maintain BIS of 50. Patients in both groups will receive 500ml of 100 % oxygen as fresh gas flow. The % of time bispectral index (BIS) is within the 10 of set target BIS of 50 will be the primary outcome measure. The secondary outcome measures will be median performance error (MDPE)(2), median absolute performance error (MDAPE)(2), wobble(2), divergence(2), amount of isoflurane used and hemodynamic parameters will be secondary outcome measures.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The basic components in a closed loop anesthesia delivery system are: (1) a system under control- patient; (2) a controlled variable that measures depth of anesthesia, (3) a set point for this variable specified by the user, (4) an actuator which comprises an algorithm to translate a measured value of the controlled variable to a particular action or the actuator to steer the controlled variable closer to the target variable.

In the proposed study, the controlled variable will be BIS. The control actuator is a patented (2158/DEL/2007) pharmacodynamic- pharmacokinetic model based adaptive infusion system termed "Improved Anesthetic Agent Delivery System (IAADS"). An IBM compatible with PENTIUM 2 or higher processor personal computer (2 GHz) is used to implement the control algorithm, provide a user interface and control communication through serial ports (RS 232) with the infusion system (Pilot- C, Frasenius, France) and a Datex vital sign monitor. We will use Avance ventilator (Datex Ohmeda, software version 5.0) with carbon di oxide absorber and ascending bellows to provide constant volume ventilation. The amount of acceptable leak in the circuit will be reduced to ≤ 150 ml min-1 determined during ventilation of a test lung. Low fresh gas flows will be used during the study. Isoflurane will injected into the expiratory limb of circle system via 20 ml Plastipak (polyethylene BD) syringe with a 100 cm long polyethylene tubing (Vygon, India) using a Pilot C Infusion pump (Fresenius vial SA, France). The stated volumetric accuracy of the infusion pump is ±2 %.

After obtaining written informed consent, patients will be randomly allocated (by closed envelope technique using computer generated random numbers) to one of the two groups- manual and automatic. The investigator will be present during the procedure for data collection purpose only and will not be involved in the conduct of anaesthesia. All patients will receive 5- 10mg oral diazepam as per institutional protocol the night before and on the morning of surgery as pre-medication. After shifting the patient to the operation table, patients will be started on normal saline 100 ml/hr (1-2 ml/kg/hr). Routine physiological monitoring will be commenced (pulse oximetry, electrocardiography, non-invasive blood pressure monitoring). BIS (Bispectral index)will be obtained by disposable sensors (Aspect medical system Inc. MA USA) attached to the forehead of the patient. Patients will receive 0.15 mg/kg of morphine sulphate before induction in aliquots of 3-5mg, during which indwelling arterial cannula, central venous line and pulmonary artery catheters (if deemed to be necessary) will be inserted.

Before induction, patients shall receive fentanyl 3μg/kg over three minutes. In automatic mode, IAADS automatically will calculate and titrate the initial and subsequent propofol infusion rate according to the weight of the patient, risk status and target BIS value, which will be set at 50 for all cases with a range of 40-60. In manual group, the propofol infusion rate will be determined by the attending anaesthesiologist according to the weight of the patient, and the target BIS of 50, with the aim to maintain BIS within 40- 60. After loss of consciousness (LOC), patients will receive 0.1mg/kg vecuronium bromide and will be intubated after 4 minutes.

The circle system will be closed after ascertaining the correct position of the endotracheal tube. In the control group, isoflurane infusion will be started into the expiratory limb of the circle at predetermined rates. The isoflurane concentration in the circuit will be built gradually over a period of 10 minutes to attain a specified BIS value. During isoflurane anaesthesia, patients will be ventilated with 100% oxygen. Fresh gas flows will be started at 500ml/min, and the ventilation will be set so as to maintain an end tidal CO2 concentration of 30-35 mmHg. If the fresh gas flows are inadequate as determined by incomplete filling of bellows, the flows will be increased gradually by 100 ml/min till a maximum of 1000 ml/min. If still there is a leak, the study will be abandoned and patient ventilated with higher flows. Thus, patients will be maintained on isoflurane injected into the expiratory limb of the circuit. Analgesia will be maintained with fentanyl 1μg/kg/hr infusion with further boluses of 1μg/kg before skin incision, sternotomy and commencement of cardiopulmonary bypass (CPB). Muscular relaxation will be maintained with a continuous infusion of vecuronium bromide 50μg/kg/hr. After 30 minutes of induction, an arterial sample will be drawn to have baseline values for blood gases, activated clotting time (ACT), and blood glucose. Patients will receive a bolus of 3 mg/kg heparin to raise the ACT above 480s. In cases of lower values, further boluses of heparin will be infused as per bull and colleagues dose response curve for heparin.

In the manual group, after the confirmation of the placement of endotracheal tube, the circle system will be closed and fresh gas flows will be started at 1000ml/min. Inhalational anaesthetics will be delivered by Fluotech 7 vapouriser (Datex ohmeda) for isoflurane. The initial dial setting will be started at 3% and after 5 minutes, flows will be reduced to 500 ml/min and isoflurane concentration will be titrated by the anaesthesiologist to maintain BIS of 50. The dial setting will be increased or decreased to maintain BIS of 50 and the number of times the vapouriser dial setting is changed will be noted. Rest of the protocol will be similar to the computer control group described above.

After the initiation of CPB, arterial blood gases, ACT and blood glucose will be determined every half an hour. An arterial partial pressure of O2 of 300-400 mmHg, ACT \>480s and blood glucose \<180mg/dl will be maintained throughout the bypass period. After successful completion of cardiopulmonary bypass, heparin will be antagonised with protamine sulphate.

During episodes when the mean arterial pressure exceeds 25% of the baseline or heart rate exceeds 100 beats/ min or 25% of the baseline, analgesia will be supplemented with fentanyl 1μg/kg. In case of persistent hypertension or tachycardia with BIS \< 50, nitroglycerine infusion will be started and titrated to control blood pressure; Esmolol (upto 0.5mg/kg IV) will be administered to control the heart rate (HR). Similarly, in case of fall in mean arterial pressure to less than 25% of the baseline in the presence of normovolemia, initially phenylephrine will be used in boluses of 0.5μg/kg. For persistent hypotension after a cumulative Phenylephrine dose of 2μg/kg, dopamine infusion will be started and titrated to maintain MAP within 25% of the baseline. Likewise, in case of decrease in HR to \<45beats/min., atropine sulphate (10μg/kg IV boluses) will be administered after excluding other treatable causes.

During CPB, patients will be shifted to propofol infusion, as the equipment for delivering fresh gases during CPB requires large fresh gas flows and circle system is not possible presently. MAP will be maintained between 50- 80 mmHg and any deviation from theses limits shall be treated with Phenylephrine boluses or sodium nitroprusside infusion. Propofol will be administered as per IAADS in computer control group and manually in the manual group to maintain BIS of 50.

Five minutes after the end of CPB, patients will be shifted back to isoflurane. In the computer control group, the concentration in the circuit for the set BIS will be achieved over 10 minutes. In the manual control group, the dial setting will be started at 3% and titrated according to the BIS. Fresh gas flows will be maintained at the same rate before the initiation of CPB.

At the end of skin closure, isoflurane, fentanyl and vecuronium will be stopped and the study protocol terminated. Patient will be shifted to propofol infusion for post operative sedation and will be shifted to post anaesthesia care unit without antagonizing muscle relaxants for elective mechanical ventilation. Patients will be extubated on meeting standard criteria for extubation. All patients will be continuously monitored for hemodynamic stability and maintenance of blood gases upto 24 hrs postoperatively. Patients will be subjected to a structured interview as modified from Brice and colleagues and described by Nordstrom for conscious awareness; on discharge from post anesthesia care unit, the day after surgery and approximately a week later.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Open Heart Surgery

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

MANUAL

In the manual group isoflurane was administered using Tech 7 vapouriser. The dial setting was controlled by the anesthesiologist to achieve and maintain a BIS of 50 during anesthesia.

Group Type ACTIVE_COMPARATOR

Conventional control

Intervention Type OTHER

The isoflurane administration to deliver anesthesia will be done conventionally through a Tec 7 vaporiser to maintain the bispectral index at 50.

IAADS group

In this group, liquid isoflurane was injected into the circuit using a syringe pump controlled by the IAADS system.The IAADS system has the algorithm to regulate the rate of infusion of isoflurane such that BIS is achieved and maintained at 50 during anesthesia.

Group Type EXPERIMENTAL

Closed loop control

Intervention Type OTHER

The isoflurane administration to maintain anesthesia will be by infusion to the anesthesia circuit using syringe pump (injection technique). The rate of delivery of isoflurane will be regulated by computer that uses a control algorithm.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Conventional control

The isoflurane administration to deliver anesthesia will be done conventionally through a Tec 7 vaporiser to maintain the bispectral index at 50.

Intervention Type OTHER

Closed loop control

The isoflurane administration to maintain anesthesia will be by infusion to the anesthesia circuit using syringe pump (injection technique). The rate of delivery of isoflurane will be regulated by computer that uses a control algorithm.

Intervention Type OTHER

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

MANUAL CONTROL AUTOMATED CONTROL

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* American Society of Anesthesiology physical status 2- 4
* elective open heart surgery under general anaesthesia
* requiring Cardio Pulmonary Bypass (CPB)

Exclusion Criteria

* body weight ±30% of the ideal body weight
* neurological disorder
* use of any psychoactive medication
* severe stenotic valve lesions
* severe pulmonary artery hypertension
* Tetrology of Fallot repair and other cyanotic heart diseases.
Minimum Eligible Age

18 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Post Graduate Institute of Medical Education and Research, Chandigarh

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Post Graduate Institute of Medical Education and Research

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Puri GD, MBBS MD PhD

Role: PRINCIPAL_INVESTIGATOR

Post Graduate Institute of Medical Education and Research, Chandigarh

Sethu Madhavan, MBBS

Role: PRINCIPAL_INVESTIGATOR

Post Graduate Institute of Medical Education and Research, Chandigarh

Preethy J Mathew, MBBS, MD

Role: PRINCIPAL_INVESTIGATOR

Post Graduate Institute of Medical Education and Research, Chandigarh

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Post graduate institute of medical education and research

Chandigarh, , India

Site Status

Countries

Review the countries where the study has at least one active or historical site.

India

References

Explore related publications, articles, or registry entries linked to this study.

Locher S, Stadler KS, Boehlen T, Bouillon T, Leibundgut D, Schumacher PM, Wymann R, Zbinden AM. A new closed-loop control system for isoflurane using bispectral index outperforms manual control. Anesthesiology. 2004 Sep;101(3):591-602. doi: 10.1097/00000542-200409000-00007.

Reference Type BACKGROUND
PMID: 15329583 (View on PubMed)

Varvel JR, Donoho DL, Shafer SL. Measuring the predictive performance of computer-controlled infusion pumps. J Pharmacokinet Biopharm. 1992 Feb;20(1):63-94. doi: 10.1007/BF01143186.

Reference Type BACKGROUND
PMID: 1588504 (View on PubMed)

Agarwal J, Puri GD, Mathew PJ. Comparison of closed loop vs. manual administration of propofol using the Bispectral index in cardiac surgery. Acta Anaesthesiol Scand. 2009 Mar;53(3):390-7. doi: 10.1111/j.1399-6576.2008.01884.x.

Reference Type BACKGROUND
PMID: 19243324 (View on PubMed)

Puri GD, Kumar B, Aveek J. Closed-loop anaesthesia delivery system (CLADS) using bispectral index: a performance assessment study. Anaesth Intensive Care. 2007 Jun;35(3):357-62. doi: 10.1177/0310057X0703500306.

Reference Type BACKGROUND
PMID: 17591128 (View on PubMed)

Madhavan JS, Puri GD, Mathew PJ. Closed-loop isoflurane administration with bispectral index in open heart surgery: randomized controlled trial with manual control. Acta Anaesthesiol Taiwan. 2011 Dec;49(4):130-5. doi: 10.1016/j.aat.2011.11.007. Epub 2011 Dec 22.

Reference Type DERIVED
PMID: 22221684 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

closed loop isoflurane

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Controlled Propofol Administration
NCT01019746 COMPLETED PHASE4
Neuroprotection During Open Heart Surgery
NCT04486690 COMPLETED PHASE3