Slope of the Pressure-Time Waveform Predicts Resistance and Compliance in Mechanically Ventilated Subjects
NCT ID: NCT00750074
Last Updated: 2017-02-28
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
12 participants
OBSERVATIONAL
2007-11-30
2010-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Respiratory Mechanics and Patient-ventilator Asynchrony Index in Patients With Invasive Mechanical Ventilation
NCT02687802
Epidemiology and Treatment Strategy of Open Respiratory Phenotype in Critically Ill Patients
NCT06393179
Neural Pressure Support, Synchrony and Respiratory Muscle Unloading
NCT05670093
Deventilation Dyspnea in COPD Patients Using NIV
NCT03503123
Respiratory Mechanics in Intensive Care Patients
NCT03420417
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Aim 2: To determine whether patient effort and level of alertness impair the accuracy of resistance and elastance measurements during pressure-preset ventilation.
Hypothesis 1: Our primary hypothesis is that the flow versus time waveform contains information sufficient to calculate the respiratory system resistance and elastance. To test the primary hypothesis, we propose to measure resistance and elastance of subjects ventilated in the ICU during assist-control ventilation (a standard constant flow, volume-preset mode). Then we will record the flow versus time waveform during pressure-preset ventilation. By extrapolating the flow versus time waveform (which is generally linear) to the time axis, one can calculate elastance since at zero flow, the alveolar pressure equals the ventilator inspiratory pressure. Then Ers = (Pinsp - Total PEEP)/Extrapolated VT, where Pinsp is the set inspiratory pressure and extrapolated VT is the tidal volume if inspiratory time had been sufficient to allow equilibration between patient and ventilator (using trigonometry). Similarly, by extrapolating the flow versus time waveform to the flow axis (to find the maximal flow), one can calculate the resistance, assuming that flow depends on the pressure difference between ventilator and patient and the square of the resistance. We will compare the values derived during pressure-preset ventilation with those determined during assist-control (taken as the true values).
Hypothesis 2: We hypothesize that inspiratory effort will be sufficient in some subjects to distort the flow versus time waveform from that which would be seen if the patient were passive, leading to erroneous values for resistance and elastance. We will estimate the respiratory drive using a standard measure, the fall in Pao during a brief inspiratory occlusion 100ms following the onset of inspiration (P0.1). Further, we will measure each subject's alertness on the Richmond Agitation-Sedation Scale (RASS). We expect our estimations of resistance and elastance to less accurate (during pressure-preset ventilation compared with assist-control) in subjects with greater respiratory drive and higher levels of alertness.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
1
During volume assist-control ventilation, a 0.4 second end-inspiratory pause will be set and the following pressures measured: peak pressure; plateau pressure; and PEEP. The following ventilator settings will be recorded: inspiratory flow; expired tidal volume; and rate. The presence or absence of autoPEEP will be noted.
During pressure-control ventilation, the flow versus time waveform will be printed from the ventilator using a conventional computer printer for later analysis. The following ventilator settings will be recorded: inspiratory pressure; PEEP; and expired tidal volume.
No interventions assigned to this group
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Exclusion Criteria
* Subjects with planned extubation at time of screening
* Subjects who are judged too hemodynamically unstable by their attending physician to participate in the study
* Subjects on high-frequency ventilation
* Subjects whose oxyhemoglobin saturation cannot be maintained at 88% or greater
* Subjects with large air leaks around the endotracheal or tracheostomy tube
* Subjects younger than 18 years old
* Inability to obtain informed consent from the subject or the subject's authorized representative
18 Years
99 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Gregory A. Schmidt
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Gregory A. Schmidt
Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Univesity of Iowa
Iowa City, Iowa, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
200608720
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.