Patients Perception of Mechanical Heart Valve Sounds: Psychoacoustics and Quality of Life
NCT ID: NCT00362401
Last Updated: 2009-09-07
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
90 participants
OBSERVATIONAL
2005-11-30
2009-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Controlled Phonation and Vocal Rest Programs After Acute Vocal Exertion in Healthy Adults
NCT03762993
Effects of Pulses on Loudness
NCT04010721
Impact of Earplugs on Mechanisms of Noise-Related Cardiovascular Disease
NCT07148817
Channel Interaction in Cochlear Implant and Speech Understanding in Noise
NCT03877211
Pitch and Loudness Perception by Cochlear Implant Listeners: Psychophysics and Objective Measures
NCT01284790
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Background: Approximately 90.000 mechanical prosthetic heart valves are implanted every year all over the world. They generate a clicking sound at closure, which can be a major problem for some patients. About 12% of them all experience annoyance, concentration disturbance, sleeping disorders and social embarrassment. All those factors could affect patients' quality of life.
Aim: to compare the sound pressure levels (SPLs) from three of the most frequently implanted mechanical heart valve prostheses, in order to determine whether there was any significant difference between the intensities of the valve sounds.
Material and Methods: We intended to include 150 patients with an implanted mechanical heart valve (ATS Medical, Medtronic-Hall or St. Jude Medical) in the aortic position between 3 months and 4 years before the analysis. For logistical reasons, the actual number of the patients included was 84. The total conducted valve sound was measured (by a method designed by the authors) for each patient. The measures took place in a bioacoustical laboratory built with a sound-insulated chamber with a very low background noise, designed for the purposes of the study. The measures were performed in German patients followed by "The Heart Centre" in Bad Oeynhausen (Herz- und Diabeteszentrum Nordrhein Westfalen, University of Bochum), where the mentioned laboratory is constructed. The sound analysis of the present study was conducted in a specially designed soundproof bioacoustic laboratory, which isolates the outside sound and vibration from the environment indoors. Inside the laboratory, heavy soundinsulated curtains were placed between the patient and the investigator chambers. The total background noise inside the patient chamber was 19 dB(A), and this was reduced further to 9 dB(A) by using a 250 Hz high-pass filter. The sounds were recorded with the patient in the supine position, and without clothes covering the chest. The valve closing sounds were recorded using a microphone (Brüel and Kjær 4179) placed 5 cm above the patient's chest. This sound was then preamplified (Brüel and Kjær 2660), amplified (Brüel and Kjær 2610) and 250 Hz high-pass filtered (Krohn-Hite 3944) (see Fig. 1). All valve sounds were recorded by the same experienced investigator and stored on an instrumentation recorder (TEAC 510) for later off-line analysis. The data acquisition time for each patient was approximately 10 min.
The patients were asked to fuldill a quality of life questionnaire (SF-36), which will be assessed in a future study regarding psychoacoustics for mechanical heart valve sounds.
Perspectives: The results obtained from this analysis will contribute to expand knowledge concerning the sound produced by these three different types of mechanical heart valve prosthesis. The study can add one important parameter in the choice of the implanted valve: patient's pleasantness. It will assess some of the most sold mechanical heart valve worldwide and the final results can contribute to elucidate which type, among those valves, that should be chosen to a specific patient.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
RETROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* patients with severe cardiac arrhythmias;
* patients with claustrophobia;
* patients who are not capable of cooperating to the experimental conditions at a sound-insulated chamber;
* patients who are unable to fulfil the quality of life questionnaire.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Heart and Diabetes Center North Rhine-Westphalia
OTHER
University of Aarhus
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Thais A. Pedersen - University of Aarhus
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Thais A. Pedersen, doctor
Role: PRINCIPAL_INVESTIGATOR
University of Aarhus
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Herz- und Diabeteszentrum Nordrhein Westfalen
Bad Oeynhausen, , Germany
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
20050213 - 19/04-2006
Identifier Type: -
Identifier Source: secondary_id
20050213
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.