Using Minimally Invasive Cardiac Output Data vs. Standard Care for Patients Emergently Admitted to the Intensive Care Unit Who Are Hemodynamically Unstable
NCT ID: NCT00354211
Last Updated: 2013-02-11
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
392 participants
OBSERVATIONAL
2006-07-31
2007-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The researchers hypothesize that early detection of instability improves the prognosis and treatment outcome of emergency intensive care patients with hemodynamic instability.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Mechanically Optimizing Cardiac Preload in Heart Failure Patients
NCT04338503
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
NCT07069738
Optimal Pacing Rate for Cardiac Resynchronization Therapy
NCT06445439
Compare Remote Patient Management and Standard Care in CRT-D and ICD-patients to Assess the Effect on Heart Failure
NCT00730548
Clinical Efficacy of Remote Monitoring in the Management of Heart Failure
NCT01723865
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
It is conceivable that there is a window of opportunity during the phases of hemodynamic instability where therapeutic interventions have the greatest potential to influence the subsequent course of critical illness. Large scale uses of therapeutic protocols for early intervention have been hampered by logistic problems. The burden of installing invasive hemodynamic monitoring and protocols is labor intensive and requires a continuous presence of personnel with a thorough understanding of complex physiology. Various techniques have been introduced for monitoring cardiac output, stroke volume, or their surrogates. The disadvantage of these technologies so far have included user dependence of measurements results, need for calibration, and limitations in applicability. Edwards Lifesciences has developed a new algorithm for the determination of cardiac output using arterial pressure data. The FloTrac™ system, which includes the FloTrac™ sensor and Vigileo™ monitor, is utilized to capture the arterial pressure-based cardiac output measurement, which will be hereinafter referred to as APCO (Arterial Pressure Cardiac Output). This system uses an existing arterial catheter (placed in the femoral or radial artery) and does not require calibration by an external reference method. We hypothesize that using the FloTrac™ system to continuously monitor cardiac output, in addition to traditional vital signs, cardiovascular instability will be identified earlier and result in earlier intervention. In addition, following earlier diagnosis, more precise intervention will be available. If this can be achieved, patients will likely show better outcomes by reduced length of hospital stay, ICU time, Mechanical Ventilation time, incidence of renal compromise, and other related morbidity/mortality and need less ICUresources.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
1
FLOTRAC™ SYSTEM
minimally invasive cardiac output system consisting of arterial line sensor and cardiac output bedside monitor (device)
2
Control Group
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
minimally invasive cardiac output system consisting of arterial line sensor and cardiac output bedside monitor (device)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patient diagnosed with hemodynamic instability at or becomes unstable within 6 hours of ICU admission.
* Patient must require an indwelling radial or a femoral artery catheter.
* Patient is included in the study according to the specific regulations of the participating center: this may include a deferred consent, consent by designee, consent by independent physician or a combination thereof.
* Patient must be 18 years old or older.
Exclusion Criteria
* Patients with a pulmonary artery catheter.
* Patients who are hemodynamically stable.
* Patients with history or clinical findings of aortic valve regurgitation.
* Patients being treated with an intra-aortic balloon pump.
* Female patient is pregnant.
* Patient is currently participating in an investigational drug or another device study.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Edwards Lifesciences
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jukka Takala, M.D., Ph.D.
Role: PRINCIPAL_INVESTIGATOR
University Hospital Bern (Inselspital)
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Kuopio University Hospital
Kuopio, , Finland
Tampere Unversity Hospital
Tampere, , Finland
University Hospital Bern (Inselspital)
Bern, , Switzerland
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Takala J, Ruokonen E, Tenhunen JJ, Parviainen I, Jakob SM. Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: a multi-center randomized controlled trial. Crit Care. 2011 Jun 15;15(3):R148. doi: 10.1186/cc10273.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Study # 2005-06, Revision B
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.