Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE4
160 participants
INTERVENTIONAL
2005-12-31
2007-04-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Laryngeal Mask Airway Facilitates a Safe and Smooth Emergence From Anesthesia in Patients Undergoing Craniotomy
NCT05253404
Limiting Emergence Phenomena After General Anesthesia With Combined LMA and ETT Airway Management Technique
NCT02708836
AMBU AScope2 Fiberoptic Intubation Versus Fastrach Intubating LMA
NCT01656967
Pragmatic Airway Resuscitation Trial
NCT02419573
Ambu Aura-i Laryngeal Mask Versus Air-Q Intubating Laryngeal Airway for Tracheal Intubation in Adults
NCT02226211
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The manufacturer of the reusable LMA-ClassicTM states that "the success rate of intubation through the standard LMA-ClassicTM is highly variable (30-93%)," whereas the success rate of the disposable version, LMA-UniqueTM, has been found to be only 21%1. An LMA specifically designed for intubation now exists and improves the success rate of intubation. The reusable LMA-FastrachTM or Intubating-LMATM (ILMA) is a rigid and anatomically curved airway tube. It is wide enough to accommodate 8.0 mm cuffed endotracheal tubes. Attached to the ILMA is a rigid handle to aid in one-handed insertion, removal, and adjustment. Success rates for intubating through the ILMA are 96.5% when inserted blindly and 100% with fiberoptic guidance2. No disposable version of the ILMA presently exists.
The Ambu® Laryngeal Mask (ALMA) is a new disposable laryngeal mask with an anatomical curve similar to the ILMA. The reasons for the use of disposable products can be many and varied. The residual risk of the transmission of germs and protein particles represents one indication. If supra-glottic airway devices are used electively or in emergencies, e.g. for HIV-positive patients or those infected with Creutzfeldt-Jacob disease, reuse of the products is not desirable. Disposable products, on the other hand, offer the benefit that the transmission of germs is avoided, and at the same time offer considerable economic advantages due to the much lower price of the product. The disposable ALMA has been proven as an effective and safe supra-glottic airway device3. Upon fiberoptic visualization through its shaft, the glottis was visualized 91.5% of the time, indicating that this device may be used as an intubation conduit. The purpose of this study is to determine if the ALMA is also safe and effective as an intubating conduit. The hypothesis is that the ALMA will perform as well as, if not better than the LMA-UniqueTM.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SINGLE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Ambu Laryngeal Mask
Aintree Exchange Catheter
Laryngeal Mask Airway
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* The patient is 18-65 years of age
* The patient weighs \> 50 kg with a BMI \< 30 kg/m2
* The patient has a Mallampati grade I -III airway
* The patient is undergoing general anesthesia with controlled ventilation for minor routine surgical procedures
* The period of anesthesia time is \>30 minutes
Exclusion Criteria
* The patient is \< 18 or \>65 years of age
* The patient weighs \< 50 kg or has a BMI \> 30 kg/m2
* The patient has a history of inadequate cervical mobility
* The patient has a history or signs of difficult airway management
* The patient has a Mallampati grade IV Class airway
* The patient has a mouth opening \< 2.5 cm
* The patient has an oral cavity disease
* The patient has a cervical malformation
* The patient had upper respiratory tract symptoms in the previous 10 days
* The patient is to have surgery performed to the head/neck or thoracoabdominal cavities needing to be paralyzed, or in the lateral/prone position
* The patient is considered at risk of aspiration (non-fasted, gastroesophageal reflux/disease)
18 Years
80 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ambu A/S
INDUSTRY
The University of Texas Health Science Center, Houston
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Carin A. Hagberg
Professor and Chairman, Joseph C. Gable, M.D., Endowed Chair
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Carin A. Hagberg, M.D.
Role: PRINCIPAL_INVESTIGATOR
The University of Texas Medical School at Houston
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Memorial Hermann Hospital
Houston, Texas, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
HSC-MS-05-0347
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.