Ambu® Laryngeal Mask as an Intubation Conduit

NCT ID: NCT00272194

Last Updated: 2016-03-23

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE4

Total Enrollment

160 participants

Study Classification

INTERVENTIONAL

Study Start Date

2005-12-31

Study Completion Date

2007-04-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to determine if the Ambu Laryngeal Mask can be used as an intubation conduit for endotracheal intubation.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The laryngeal mask airway (LMA) is an established supra-glottic device that provides better ventilation than traditional mask ventilation and is less invasive than endotracheal intubation. Being less invasive, it is commonly used for short elective surgical procedures. Its ability to be both easily and rapidly inserted also makes it useful as a rescue device in difficult and failed intubations. Being a supra-glottic device, the LMA does not protect patients from regurgitation and aspiration. Additionally, patients requiring alternative positions, such as prone or lateral, or those having surgery in the neck/head area are contra-indicated for LMA use due to risk of possible movement of the LMA, and therefore possible loss of airway patency. Thus, the LMA can be utilized as an intermediary method of airway management to endotracheal intubation.

The manufacturer of the reusable LMA-ClassicTM states that "the success rate of intubation through the standard LMA-ClassicTM is highly variable (30-93%)," whereas the success rate of the disposable version, LMA-UniqueTM, has been found to be only 21%1. An LMA specifically designed for intubation now exists and improves the success rate of intubation. The reusable LMA-FastrachTM or Intubating-LMATM (ILMA) is a rigid and anatomically curved airway tube. It is wide enough to accommodate 8.0 mm cuffed endotracheal tubes. Attached to the ILMA is a rigid handle to aid in one-handed insertion, removal, and adjustment. Success rates for intubating through the ILMA are 96.5% when inserted blindly and 100% with fiberoptic guidance2. No disposable version of the ILMA presently exists.

The Ambu® Laryngeal Mask (ALMA) is a new disposable laryngeal mask with an anatomical curve similar to the ILMA. The reasons for the use of disposable products can be many and varied. The residual risk of the transmission of germs and protein particles represents one indication. If supra-glottic airway devices are used electively or in emergencies, e.g. for HIV-positive patients or those infected with Creutzfeldt-Jacob disease, reuse of the products is not desirable. Disposable products, on the other hand, offer the benefit that the transmission of germs is avoided, and at the same time offer considerable economic advantages due to the much lower price of the product. The disposable ALMA has been proven as an effective and safe supra-glottic airway device3. Upon fiberoptic visualization through its shaft, the glottis was visualized 91.5% of the time, indicating that this device may be used as an intubation conduit. The purpose of this study is to determine if the ALMA is also safe and effective as an intubating conduit. The hypothesis is that the ALMA will perform as well as, if not better than the LMA-UniqueTM.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Intubation, Endotracheal

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Blinding Strategy

SINGLE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Ambu Laryngeal Mask

Intervention Type DEVICE

Aintree Exchange Catheter

Intervention Type DEVICE

Laryngeal Mask Airway

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* The patient is ASA 1-3 presenting for an elective surgical procedure
* The patient is 18-65 years of age
* The patient weighs \> 50 kg with a BMI \< 30 kg/m2
* The patient has a Mallampati grade I -III airway
* The patient is undergoing general anesthesia with controlled ventilation for minor routine surgical procedures
* The period of anesthesia time is \>30 minutes

Exclusion Criteria

* The patient is an ASA classification 4
* The patient is \< 18 or \>65 years of age
* The patient weighs \< 50 kg or has a BMI \> 30 kg/m2
* The patient has a history of inadequate cervical mobility
* The patient has a history or signs of difficult airway management
* The patient has a Mallampati grade IV Class airway
* The patient has a mouth opening \< 2.5 cm
* The patient has an oral cavity disease
* The patient has a cervical malformation
* The patient had upper respiratory tract symptoms in the previous 10 days
* The patient is to have surgery performed to the head/neck or thoracoabdominal cavities needing to be paralyzed, or in the lateral/prone position
* The patient is considered at risk of aspiration (non-fasted, gastroesophageal reflux/disease)
Minimum Eligible Age

18 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Ambu A/S

INDUSTRY

Sponsor Role collaborator

The University of Texas Health Science Center, Houston

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Carin A. Hagberg

Professor and Chairman, Joseph C. Gable, M.D., Endowed Chair

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Carin A. Hagberg, M.D.

Role: PRINCIPAL_INVESTIGATOR

The University of Texas Medical School at Houston

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Memorial Hermann Hospital

Houston, Texas, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

HSC-MS-05-0347

Identifier Type: -

Identifier Source: org_study_id