A New Flexible Extended-Length Pharyngeal Airway for Deep Sedation

NCT ID: NCT04419883

Last Updated: 2020-06-09

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

86 participants

Study Classification

OBSERVATIONAL

Study Start Date

2019-03-05

Study Completion Date

2020-05-05

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this prospective pilot provider adoption study was to evaluate user experience a new airway device in adult patients with airway obstruction under deep sedation. Fifteen hospital systems served as testing sites. Fifty-four anaesthetist providers reported their experience with the airway device in 84 cases across two phases of surveying.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This multi-center proof-of-concept, descriptive, prospective, and observational study was approved by a universal Institutional Review Board (IRB) for Human Subjects Research in March 2019. Anaesthesia providers who volunteered to trial this new airway device were recruited to complete a survey tool to assess provider satisfaction of a commercially-available upper airway device (McMurray Enhanced Airway (MEA); McMurray Medical, Minneapolis, MN).

The MEA is a novel upper airway device with numerous enhanced features relative to currently available airway management products (Figure 1). The MEA has longer flexible tubing allowing for displacement of pharyngeal tissue that oral airways are unable to reach, and avoiding the need for chin lift/jaw thrust maneuvers \[16\]. The smaller diameter helps reduce stimulation and gagging and permits placement alongside an endoscopy bite block. The softer material, similar to that of a nasal airway, allows for ease of insertion and reduces potential oral injury associated with hard plastic oral airways \[16\]. An elongated cushioned bite block is designed to prevent proximal airway collapse, allow flexibility of molar placement, and decrease the risk of dental damage \[16\]. An optional connector can be connected to an anesthesia circuit or manual resuscitator, facilitating intraoral ventilation and aiding in situations such as difficult mask ventilation or when oxygen diffusion in the surgical field may present fire risk \[16\]. Furthermore, the MEA was designed to reduce need for manual stationary maneuvers by providers such as chin lift or jaw thrust, thereby preventing potential provider-patient exposure of airborne droplets and increased staffing.

Providers received device instructions for use (IFU) by training video and printed material to understand how to use and size the MEA. After using the MEA trial device in clinical practice, anaesthesia providers participated in completing the Use Survey Tool based on cases meeting the following criteria: inclusion criteria included adult patients (age \>18) experiencing an obstructive airway under deep sedation; exclusion criteria included determining that the device size was inappropriate-too big or small-for the patient, since placing an improper size could be detrimental for the patient.

The initial survey(Phase 1) was developed to evaluate current product usage, general use conditions, deep sedation conditions, general anaesthesia conditions, device performance, and overall device satisfaction using binary responses with option for subjective free response. Based on Phase 1 responses and provider feedback, Phase 2 surveys were limited to questions with ordinal responses that assessed device use satisfaction during deep sedation procedures only. Surveys were distributed with the trial devices. As this was a pilot feasibility study for the new extended pharyngeal airway device, recruitment of provider subjects was based on interest of using a novel airway device to benefit airway management when providing deep sedation in situations where airway obstruction became problematic. Surveys were voluntarily completed by the anaesthesia provider following each use. One provider could complete multiple surveys to represent individual device performance and experience. Information related to patient, provider, and device placement frequency was not collected in order to expedite response rate to learn initial provider experience. Submitted surveys underwent response analysis by an independent statistician. Due to the nature of qualitative data, descriptive statistics were used to summarize study results. No objective measures of device clinical efficacy were collected.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Upper Airway Obstruction

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Anesthesia Providers

Anesthesia providers from 15 different health care facilities in the United States.

McMurray Enhanced Airway

Intervention Type DEVICE

Provider Satisfaction of a New, Flexible Extended-Length Pharyngeal Airway to Relieve Upper Airway Obstructive During Deep Sedation: A Pilot Study

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

McMurray Enhanced Airway

Provider Satisfaction of a New, Flexible Extended-Length Pharyngeal Airway to Relieve Upper Airway Obstructive During Deep Sedation: A Pilot Study

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

MEA

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 18 years of age and older
* Scheduled for surgery with sedation/MAC anesthesia
* Patients experiencing an obstructive airway needing an airway device placed

Exclusion Criteria

• Inappropriate airway device size, too big or too small
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

McMurray Medical Group, LLC

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Roxanne R McMurray

VP of Clinical Management

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Roxanne McMurray, DNP

Role: PRINCIPAL_INVESTIGATOR

McMurray Medical Group, LLC

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Roxanne McMurray

Minneapolis, Minnesota, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

MEA-001-01

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.