Fibroscan to Guide Post Transplant Immunosuppression Minimization
NCT ID: NCT07206277
Last Updated: 2026-01-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
50 participants
INTERVENTIONAL
2025-12-01
2028-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Therefore studies are looking at safe ways to reduce or stop immunosuppression. An individual without autoimmune liver disease (these patients are at higher risk of rejection), without history of rejection, with normal blood tests (liver biochemistry, liver function, etc.) can be eligible for minimization of immunosuppression. A recent study showed use of fibroscan (an Ultrasound, which provides information on liver stiffness (diseased liver is hard while a normal liver is soft) and fat content) provides more objective information to help investigators select individuals who will tolerate immunosuppression minimization.
Our goal is to see if use of fibroscan allows the investigators to safely minimize immunosuppression in eligible individuals. The secondary aims are to assess benefit on kidney function, heart disease and risk factors for heart disease.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Prospective Studies on Immunopathogenesis of Liver Fibrosis
NCT04943978
Effect of High-protein High-fiber Diet in Patients With Autoimmune Hepatitis
NCT01655121
Differential Gene Expression of Liver Tissue and Blood From Individuals With Chronic Viral Hepatitis
NCT00160940
FGL2/Fibroleukin and Hepatitis C Virus Recurrence Post Liver Transplantation
NCT00701272
Autoimmune Hepatitis Study
NCT00286663
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Vibration-Controlled Transient elastography (TE; FibroScan®) is a promising tool; it is a non-invasive technique for assessment of liver stiffness measurement (LSM) that additionally provides the controlled attenuation parameter (CAP), which reflects hepatic steatosis. TE accurately predicts degree of liver fibrosis and portal hypertension regardless of etiology of liver disease (9-11). In the pre-transplant setting it is a common point-of-care tool that has led to reduced need for liver biopsy, risk stratification of patients with non-alcoholic fatty liver disease (12), and use as a guide to treat patients with Hepatitis B infection (13).
The use of TE post LT remains limited with a scarcity of studies. The few studies that exist are limited by a small sample size and short follow up post-LT. Nevertheless, these studies show there is a correlation between TE and severity of acute cellular rejection (r=0.6; p\< 0.001) (10); fibrosis and degree of portal hypertension (14); association with other diseases (idiopathic hepatitis, steatohepatitis, cholangitis, de novo or recurrent disease) (9); association with steatosis (AUROC 0.88) (15); and association with decompensation and graft/patient survival (16).
In a recent study, TE was used to identify individuals with low risk of rejection who could safely undergo IS minimization. Authors showed that subclinical allo-immune injury was associated with increased LSM and that patients with LSM below 8.4 kPa had a negligible probability of having active alloimmune damage (11%); these patients could potentially have reduction of IS (7). This study provides the scientific basis for assessing the use of TE as a guide to IS management.
The aim of this study is to assess if TE can be used to safely guide IS minimization in stable post-LT patients. The secondary aims will include impact on renal function, MS, CVD, malignancy, graft and patient survival. In a nested study, the investigators will explore the use of TE to investigate the effect of type of immunosuppression used and the development of hepatic steatosis, based on the CAP score (nested case-control study).
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Standard of Care
Followed per standard of care
No interventions assigned to this group
Immunosuppression minimization
will have immunosuppression reduction during the study using fibroscan
Immunosuppression reduction
In patients with LSM \< 8.4 kPa we will gradually reduce IS by 30% (e.g. if on tacrolimus 6 mg daily, dose will be reduced to 4 mg daily) over three months. In patients with immunosuppression reduction we will perform TE at 4, 7 and 12 months after IS reduction to ensure there is no change in LSM. We will get liver biochemistry every 2 weeks x 4 months to ensure labs remain within normal range. Following this, patients will resume monthly labs.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Immunosuppression reduction
In patients with LSM \< 8.4 kPa we will gradually reduce IS by 30% (e.g. if on tacrolimus 6 mg daily, dose will be reduced to 4 mg daily) over three months. In patients with immunosuppression reduction we will perform TE at 4, 7 and 12 months after IS reduction to ensure there is no change in LSM. We will get liver biochemistry every 2 weeks x 4 months to ensure labs remain within normal range. Following this, patients will resume monthly labs.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* 18 years or older
Exclusion Criteria
* abnormal liver enzymes (ALT \> 50; bilirubin \> 19 umol/L)
* transplant for autoimmune liver disease (autoimmune hepatitis, primary sclerosing cholangitis, and primary biliary cholangitis)
* presence of HCV RNA
* presence of HBV DNA
* presence of class II donor specific antibodies (DSA; pre-existing or de novo)
* beyond 6 years of transplantation
* presence of ascites, decompensated heart failure, biliary obstruction, CKD (bl eGFR 30 ml/min/1.73m2 or less), re-transplantation, or multi-visceral transplant.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Alberta
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Alberta
Edmonton, Alberta, Canada
Countries
Review the countries where the study has at least one active or historical site.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Pro00148986
Identifier Type: -
Identifier Source: org_study_id
More Related Trials