The Accuracy of Continuous Glucose Monitoring Systems in Critically Ill Patients
NCT ID: NCT07201155
Last Updated: 2025-10-01
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
55 participants
OBSERVATIONAL
2024-05-01
2024-10-10
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Methods: This prospective observational study included patients with BG\>180 mg/dL on intravenous insulin therapy. Blood glucose was monitored using point-of-care (POC), arterial blood gas analysis (aBG), and CGMS. CGMS values were paired 1:1 with POC and aBG values. CGMS accuracy was evaluated using MARD, ISO 15197-2013, CLSI POCT12-A3, and Clarke Error Grid Analysis.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Continuous Glucose Monitoring System: Accuracy and Prognostic Value in Critically Ill Patients
NCT07108179
Assessment of the Accuracy,Feasibility,Safety of Continuous Glucose Monitoring System
NCT03120091
Continuous Glucose Monitoring in the Intensive Care Unit
NCT06190808
Continuous Glucose Monitoring in Hospitalized Patients With Diabetes Mellitus
NCT04653454
The Management of Glucose Control and Hypoglycemic Prevention Using Continuous Glucose Monitoring System in Patients With Type 1 Diabetes
NCT04684030
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
OTHER
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Continuous Glucose Monitoring Systems
A trained research member placed the AiDEX® Dynamic Continuous Glucose Monitoring System (Microtech Medical Devices (Hangzhou) Co., Ltd.) on the patient's abdomen, about 3-10 cm to the left or right of the navel, or on the back of the upper arm, according to the instructions. The sensor began to collect data 1-4 hours after successful activation, recording blood glucose values every 5 minutes for 7 consecutive days. For patients who stayed in the ICU for less than 7 days, the continuous glucose monitoring (CGM) was terminated on the day of ICU discharge, and the CGM device was removed.
Patients monitored their blood glucose using fingerstick point-of-care (POC) measurements every 1-6 hours as needed and had routine arterial blood gas analysis 4-6 times a day. After 24 hours of patient wear, the arterial blood gas glucose (aBG) was used to calibrate the CGMS device at least twice a day. Nurses recorded CGMS data paired with POC values and aBG values in a 1:1 format.
Continuous Glucose Monitoring
This study is a single-center, prospective, observational study conducted in the Intensive Care Unit (ICU) of Nanfang Hospital, Southern Medical University, from May 2024 to August 2024. Patients with elevated blood glucose levels (BG\>180 mg/dL) undergoing intravenous insulin therapy were included. Simultaneous blood glucose monitoring was performed using fingerstick blood samples and arterial blood gas analysis, along with the installation of CGMS for concurrent monitoring. CGMS data (CGM values) were recorded in a 1:1 paired format with fingerstick point-of-care (POC) values and arterial blood gas (aBG) values. The correlation of paired blood glucose data was examined using Pearson's correlation coefficient. The accuracy of CGMS was assessed using metrics such as Mean Absolute Relative Difference (MARD), ISO 15197-2013, CLSI POCT12-A3, and Clarke Error Grid Analysis, analyzed with R v.4.4.1 software.
Continuous Glucose Monitoring
Patients who met the inclusion and exclusion criteria were enrolled in the study after obtaining informed consent from the patient or their legal representative. A trained research member placed the AiDEX® Dynamic Continuous Glucose Monitoring System (Microtech Medical Devices (Hangzhou) Co., Ltd.) on the patient's abdomen, about 3-10 cm to the left or right of the navel, or on the back of the upper arm, according to the instructions. The sensor began to collect data 1-4 hours after successful activation, recording blood glucose values every 5 minutes for 7 consecutive days. For patients who stayed in the ICU for less than 7 days, the continuous glucose monitoring (CGM) was terminated on the day of ICU discharge, and the CGM device was removed.
CGMS
Patients who met the inclusion and exclusion criteria were enrolled in the study after obtaining informed consent from the patient or their legal representative. A trained research member placed the AiDEX® Dynamic Continuous Glucose Monitoring System (Microtech Medical Devices (Hangzhou) Co., Ltd.) on the patient's abdomen, about 3-10 cm to the left or right of the navel, or on the back of the upper arm, according to the instructions. The sensor began to collect data 1-4 hours after successful activation, recording blood glucose values every 5 minutes for 7 consecutive days. For patients who stayed in the ICU for less than 7 days, the continuous glucose monitoring (CGM) was terminated on the day of ICU discharge, and the CGM device was removed.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Expected ICU stay of at least 3 days;
3. Elevated blood glucose (BG \>180 mg/dL) requiring intravenous insulin therapy;
4. Informed consent obtained from the patient or their legally authorized representative.
Exclusion Criteria
2. Uncorrected diabetic ketoacidosis; ability to self-feed; planned magnetic resonance imaging (MRI) examination;
3. Pregnancy or breastfeeding;
4. Extensive skin burns, dermatitis, or severe infections precluding the use of a continuous glucose monitoring system;
5. Severe brain injury, brain death, or moribund state;
6. Deemed unsuitable for study participation by the investigator.
18 Years
75 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Nanfang Hospital, Southern Medical University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Nanfang Hospital, Southern Medical University
Guangzhou, Guangdong, China
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
NFEC-2025-052
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.