The Accuracy of Continuous Glucose Monitoring Systems in Critically Ill Patients

NCT ID: NCT07201155

Last Updated: 2025-10-01

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

55 participants

Study Classification

OBSERVATIONAL

Study Start Date

2024-05-01

Study Completion Date

2024-10-10

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Abstract: Hyperglycemia, hypoglycemia, and glucose variability in ICU patients are associated with adverse outcomes. Continuous Glucose Monitoring Systems (CGMS) offer dynamic glucose monitoring and early warnings to improve glucose management. This study aims to evaluate the accuracy and reliability of the CGMS (Microtech AiDEX®) in critically ill patients and its performance under acidosis conditions, providing evidence for its application in the ICU.

Methods: This prospective observational study included patients with BG\>180 mg/dL on intravenous insulin therapy. Blood glucose was monitored using point-of-care (POC), arterial blood gas analysis (aBG), and CGMS. CGMS values were paired 1:1 with POC and aBG values. CGMS accuracy was evaluated using MARD, ISO 15197-2013, CLSI POCT12-A3, and Clarke Error Grid Analysis.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hyperglycemia in Critically Ill Patients

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

OTHER

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Continuous Glucose Monitoring Systems

A trained research member placed the AiDEX® Dynamic Continuous Glucose Monitoring System (Microtech Medical Devices (Hangzhou) Co., Ltd.) on the patient's abdomen, about 3-10 cm to the left or right of the navel, or on the back of the upper arm, according to the instructions. The sensor began to collect data 1-4 hours after successful activation, recording blood glucose values every 5 minutes for 7 consecutive days. For patients who stayed in the ICU for less than 7 days, the continuous glucose monitoring (CGM) was terminated on the day of ICU discharge, and the CGM device was removed.

Patients monitored their blood glucose using fingerstick point-of-care (POC) measurements every 1-6 hours as needed and had routine arterial blood gas analysis 4-6 times a day. After 24 hours of patient wear, the arterial blood gas glucose (aBG) was used to calibrate the CGMS device at least twice a day. Nurses recorded CGMS data paired with POC values and aBG values in a 1:1 format.

Intervention Type DEVICE

Continuous Glucose Monitoring

This study is a single-center, prospective, observational study conducted in the Intensive Care Unit (ICU) of Nanfang Hospital, Southern Medical University, from May 2024 to August 2024. Patients with elevated blood glucose levels (BG\>180 mg/dL) undergoing intravenous insulin therapy were included. Simultaneous blood glucose monitoring was performed using fingerstick blood samples and arterial blood gas analysis, along with the installation of CGMS for concurrent monitoring. CGMS data (CGM values) were recorded in a 1:1 paired format with fingerstick point-of-care (POC) values and arterial blood gas (aBG) values. The correlation of paired blood glucose data was examined using Pearson's correlation coefficient. The accuracy of CGMS was assessed using metrics such as Mean Absolute Relative Difference (MARD), ISO 15197-2013, CLSI POCT12-A3, and Clarke Error Grid Analysis, analyzed with R v.4.4.1 software.

Intervention Type DEVICE

Continuous Glucose Monitoring

Patients who met the inclusion and exclusion criteria were enrolled in the study after obtaining informed consent from the patient or their legal representative. A trained research member placed the AiDEX® Dynamic Continuous Glucose Monitoring System (Microtech Medical Devices (Hangzhou) Co., Ltd.) on the patient's abdomen, about 3-10 cm to the left or right of the navel, or on the back of the upper arm, according to the instructions. The sensor began to collect data 1-4 hours after successful activation, recording blood glucose values every 5 minutes for 7 consecutive days. For patients who stayed in the ICU for less than 7 days, the continuous glucose monitoring (CGM) was terminated on the day of ICU discharge, and the CGM device was removed.

Intervention Type DEVICE

CGMS

Patients who met the inclusion and exclusion criteria were enrolled in the study after obtaining informed consent from the patient or their legal representative. A trained research member placed the AiDEX® Dynamic Continuous Glucose Monitoring System (Microtech Medical Devices (Hangzhou) Co., Ltd.) on the patient's abdomen, about 3-10 cm to the left or right of the navel, or on the back of the upper arm, according to the instructions. The sensor began to collect data 1-4 hours after successful activation, recording blood glucose values every 5 minutes for 7 consecutive days. For patients who stayed in the ICU for less than 7 days, the continuous glucose monitoring (CGM) was terminated on the day of ICU discharge, and the CGM device was removed.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Age ≥18 years and ≤75 years;
2. Expected ICU stay of at least 3 days;
3. Elevated blood glucose (BG \>180 mg/dL) requiring intravenous insulin therapy;
4. Informed consent obtained from the patient or their legally authorized representative.

Exclusion Criteria

1. Severe hepatic failure (Child-Pugh class C) or marked liver dysfunction (total bilirubin ≥50 μmol/L and alanine aminotransferase ≥3 times the upper limit of normal);
2. Uncorrected diabetic ketoacidosis; ability to self-feed; planned magnetic resonance imaging (MRI) examination;
3. Pregnancy or breastfeeding;
4. Extensive skin burns, dermatitis, or severe infections precluding the use of a continuous glucose monitoring system;
5. Severe brain injury, brain death, or moribund state;
6. Deemed unsuitable for study participation by the investigator.
Minimum Eligible Age

18 Years

Maximum Eligible Age

75 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Nanfang Hospital, Southern Medical University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Nanfang Hospital, Southern Medical University

Guangzhou, Guangdong, China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

NFEC-2025-052

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.