Clinical Study to Estimate Bone Mineral Density With the POROUS Ultrasound Device
NCT ID: NCT07187518
Last Updated: 2025-11-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
350 participants
INTERVENTIONAL
2025-11-14
2026-11-13
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The POROUS ultrasound device offers a different approach by measuring various properties of the outer layer of the bone in the lower leg. It has several advantages over DXA: (1) higher and three-dimensional image resolution; (2) the ability to measure bone properties without radiation; (3) portability, it is a mobile medical device; 4) lower operational costs.
For this clinical study, we will recruit men and women between the ages of 21 and 55. Most of these study participants will not have evident clinical risks for osteoporosis. The goal for including this age group is to estimate the range of BMD values for younger people before BMD declines with age. In a separate clinical study, we are recruiting older participants. The study is anticipated to last one year.
Our major research questions are:
* Can the POROUS ultrasound device estimate BMD?
* How does its performance compare to DXA?
* What is the safety of the new device?
The participants will:
* answer questions about their medical history.
* be measured for height and weight.
* be examined with the two devices, DXA and POROUS.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Study to Predict the Risk of Bone Fractures With the POROUS Ultrasound Device
NCT06567054
Develop and Validate Ultrasonic Device for Osteoporotic Fracture Risk Assessment
NCT01123421
Reference Curve on Bone Mineral Density in Young Adult: French Multicenter Study
NCT03316625
The Osteoporotic Fracture Classification-based Scoring System for Treatment Decision in Thoracolumbar Osteoporotic Fractures
NCT07027306
Peripheral Mononuclear Cells to Screen, Monitor and Stratify the Population at Risk of Osteoporosis and Fractures
NCT06551155
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Osteoporosis is defined as a systemic skeletal disease characterized by low mineral bone mass and microarchitectural deterioration of bone tissue (Consensus Conference, 1994). This increased bone fragility is associated with susceptibility to fractures, which have substantial economic and societal burdens. Osteoporosis is routinely diagnosed through bone density assessments; however, there is a shortage of accurate means to characterize bone microstructure for diagnostic purposes. The POROUS R4C ultrasound device is capable of providing such information in detail.
The current standard of care (SoC) physical bone parameter for examining bone health is areal BMD (aBMD), typically measured by dual-energy X-ray absorptiometry (DXA) at the hip or spine. Scaling is given to score the patient's aBMD in comparison to a reference of a healthy bone. The resulting T Score compares the patient's aBMD to the peak aBMD of young adults of the same sex, while the Z score compares it to the average aBMD of the same age and sex. According to the operational WHO definition (1994), a T Score of -1.0 or above is considered normal, while scores between -1.0 and -2.5 indicate osteopenia, and scores of -2.5 or lower indicate osteoporosis.
The rationale for the clinical investigation:
Quantitative ultrasound (QUS) devices have several substantial advantages over X-ray-based technologies: a better safety profile (non-ionizing radiation), cost-efficiency, usability, and portability. These advantages can result in improved accessibility at point-of-care. The major challenge is, nonetheless, clinical performance. QUS devices that assess bone health have demonstrated varying performance in estimating surrogate aBMD values. aBMD estimation is calculated by empirical correlation with DXA reference measurements using a combination of ultrasound parameters and anthropometric information. We follow these clinical performance standards for aBMD estimation using the investigational POROUS R4C ultrasound device.
The investigational device:
The POROUS R4C is a non-invasive QUS device for measuring and quantifying microstructural, acoustic, and viscoelastic properties in cortical bone (e.g., in the tibia of the lower limb). The device can be used to acquire single-channel raw data in a pulse-echo mode and perform innovative signal processing and imaging techniques to determine physical bone biomarkers. Examples of physical bone biomarkers are cortical thickness and the speed of sound in the radial direction using refraction-corrected image reconstruction and frequency-dependent attenuation and pore-size distribution using spectral backscatter analysis. The measurement data are recorded by the acquisition software, and the post-processing analysis is done using separate algorithms. In pre-clinical and clinical studies (completed, ongoing, or planned), the effectiveness of spectral ultrasound backscatter analysis and refraction-corrected image reconstruction methods are being evaluated to assess bone quality, health, and biomechanical competence. In first-in-human pilot studies, the POROUS technology has demonstrated the feasibility of measuring cortical bone properties and estimating aBMD in smaller cohorts of participants.
The overall purpose of the clinical investigation:
In this confirmatory clinical investigation, data will be collected to characterize cortical bone properties and calculate surrogate aBMD values for young and middle-aged (21 to 55 years) men and women. In a separate confirmatory clinical investigation (POROUS-preFX, NCT06567054), data will be collected to characterize cortical properties and calculate surrogate aBMD values in older men and women (56 to 85 years). Together, the combined data will represent a broader range of estimated surrogate aBMD values and generate a POROUS T score for diagnostic purposes.
Clinical investigation design:
This is a cross-sectional, single-cohort, age- and sex-stratified study of participants aged 21 to 55 years. The rationale for selecting this age range is to gather data for this age group, while data from older participants are gathered in an independent clinical investigation (POROUS-preFX, NCT06567054).
Participants will be enrolled into different groups based on their age (consisting of five-year bands) and sex (males or females). All participants will undergo measurements using the investigational POROUS R4C ultrasound device and the comparator DXA device. Prior knowledge of aBMD values, whether measured by DXA or another type of bone densitometer, will not be recorded to avoid selection bias. The final analysis of study results will incorporate measured POROUS parameters (e.g., cortical thickness, cortical bone pore diameter distribution, cortical bone frequency-dependent ultrasound attenuation, cortical bone backscatter coefficient, speed of sound in the radial direction), anthropometric information (weight, height, BMI, sex), and age will be used to create a multivariate partial least squares (PLS) model to predict DXA-derived aBMD. This prediction model will be similar to the one described in the pilot studies (Armbrecht et al., JBMR Plus, 2021; Dehnen et al., Front Endocrinol, 2024). However, the formula will be re-developed based on the results of this study. The predictions will be made with DXA-derived aBMD values of the femur neck, total proximal femur, and lumbar spine collected in this study. Cross-calibration of DXA devices from different manufacturers will be done if necessary.
The participants will also receive a questionnaire regarding their medical history and any medications that may impact bone health.
Primary objective:
• To assess the performance of the POROUS R4C ultrasound device in estimating surrogate aBMD values (total femur).
Secondary objectives:
* To assess the performance of the POROUS R4C ultrasound device in estimating surrogate aBMD values (femoral neck and lumbar spine).
* To assess the safety of the POROUS R4C ultrasound device by monitoring adverse events affecting participants or healthcare professionals using the device.
Exploratory objectives:
* To generate T-score and Z-score scales (total femur, femoral neck, and lumbar spine) for the POROUS R4C ultrasound device and assess their performance.
* To collect data on cortical bone properties measured by POROUS R4C ultrasound device in young and middle-aged men and women.
* To assess the reproducibility of direct measurements by the POROUS R4C
Participants:
The clinical investigation will include 350 female and male participants. Prior knowledge of bone health or aBMD values will not be considered an enrolment criterion. All participants will undergo measurement using the investigational POROUS R4C ultrasound device at the midshaft tibia and a comparator DXA device at the total femur, femoral neck, and lumbar spine. The participants are stratified according to sex and age stratification into five-year bands:
* Age group 21-25, males/females = 25 per group, total = 50.
* Age group 26-30, males/females = 25 per group, total = 50.
* Age group 31-35, males/females = 25 per group, total = 50.
* Age group 36-40, males/females = 25 per group, total = 50.
* Age group 41-45, males/females = 25 per group, total = 50.
* Age group 46-50, males/females = 25 per group, total = 50.
* Age group 31-55, males/females = 25 per group, total = 50.
Screened and eligible individuals will be enrolled in the investigation until the necessary sample size for his/her corresponding group (based on age and sex) has been reached (see Table above). To avoid over-recruiting, once the necessary sample size for one group has been reached, no further individuals with matching age band or sex will be enrolled in the investigation.
Duration of the clinical investigation:
The planned overall clinical investigation is expected to last up to 12 months, from the first participant's enrolment until the last participant's clinical assessment. However, if the last participant's assessment is completed before the 12-month mark, the Sponsor may choose to conclude the investigation earlier.
Clinical procedures:
The following clinical procedures are performed during the investigation:
Screening:
* Inclusion/exclusion criteria
* Enrolment into corresponding age and sex groups.
* Informed consent
Clinical assessments:
* Measuring with the POROUS R4C ultrasound device at the central antero-medial tibia region
* Scanning with DXA (aBMD of the lumbar spine and proximal femur).
* Assessment of medical conditions and concomitant medication using a questionnaire.
* Recording of adverse events.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
BMD estimation in young and middle-aged men and women
All participants are examined with the investigational device (POROUS R4C ultrasound device) and a comparator device (DXA).
Measurements with the POROUS R4C ultrasound device at the midshaft tibia
The POROUS R4C ultrasound device measures the cortical bone of the midshaft tibia. Ultrasound gel is first applied onto the skin surface, covering the region of interest, followed by placing the ultrasound transducer with a medical ultrasound gel pad placed in front of it. At the marked position on the leg, four technical measurement readings are performed: 2x CortBS and 2x Multifocus, with repositioning the probe between individual measurements, the chronological order of which is not crucial. Scanning time for each measurement takes 1-2 minutes. Out of the four measurements, the two optimal measurements (one for CortBS and one for Multifocus) are selected by the device, based on pre-defined quality criteria.
DXA measurement of the hip and lumbar spine
The following DXA measurements are to be performed: • Spine L1-4 • Hip left • Hip right (alternatively, if a valid measurement of the left hip is not possible) Scanning takes approximately 15 minutes. A maximum number of one repeat measurement is planned (e.g., hip or spine). Note: The DXA scan of the hip is performed on the same side of the body as the POROUS R4C ultrasound scan.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Measurements with the POROUS R4C ultrasound device at the midshaft tibia
The POROUS R4C ultrasound device measures the cortical bone of the midshaft tibia. Ultrasound gel is first applied onto the skin surface, covering the region of interest, followed by placing the ultrasound transducer with a medical ultrasound gel pad placed in front of it. At the marked position on the leg, four technical measurement readings are performed: 2x CortBS and 2x Multifocus, with repositioning the probe between individual measurements, the chronological order of which is not crucial. Scanning time for each measurement takes 1-2 minutes. Out of the four measurements, the two optimal measurements (one for CortBS and one for Multifocus) are selected by the device, based on pre-defined quality criteria.
DXA measurement of the hip and lumbar spine
The following DXA measurements are to be performed: • Spine L1-4 • Hip left • Hip right (alternatively, if a valid measurement of the left hip is not possible) Scanning takes approximately 15 minutes. A maximum number of one repeat measurement is planned (e.g., hip or spine). Note: The DXA scan of the hip is performed on the same side of the body as the POROUS R4C ultrasound scan.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Written informed consent has been obtained.
Exclusion Criteria
* Open wounds or skin infections at the measurement site of the POROUS R4C ultrasound device.
* Inability to undergo the investigations required by the Clinical Investigation Plan (CIP) or cognitive limitations that preclude understanding of the Participant Information Sheet and the Informed Consent Document.
* Pregnancy and breastfeeding
* Individual is in custody by order of an authority or a court of law.
* Close affiliation with an investigational site, e.g., employment at an investigational site, close relative of an investigator, or dependent person (e.g., student of the investigational site).
21 Years
55 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
German Federal Ministry of Education and Research
OTHER_GOV
POROUS GmbH
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Gabriele Armbrecht, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
Charite University, Berlin, Germany
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of Endocrinology and Metabolism, Charité Universitätsmedizin Berlin, Campus Mitte
Berlin, , Germany
Centre of Muscle and Bone Research (ZMK), Charité Universitätsmedizin Berlin, Campus Benjamin Franklin
Berlin, , Germany
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Dehnen C, Galindo A, Hoff P, Palme O, Maurer L, Raum K, Wiebe E. Quantitative ultrasound imaging reveals distinct fracture-associated differences in tibial intracortical pore morphology and viscoelastic properties in aged individuals with and without diabetes mellitus - an exploratory study. Front Endocrinol (Lausanne). 2024 Dec 16;15:1474546. doi: 10.3389/fendo.2024.1474546. eCollection 2024.
Armbrecht G, Nguyen Minh H, Massmann J, Raum K. Pore-Size Distribution and Frequency-Dependent Attenuation in Human Cortical Tibia Bone Discriminate Fragility Fractures in Postmenopausal Women With Low Bone Mineral Density. JBMR Plus. 2021 Sep 2;5(11):e10536. doi: 10.1002/jbm4.10536. eCollection 2021 Nov.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
13GW0807
Identifier Type: OTHER_GRANT
Identifier Source: secondary_id
R4C-BMD-01
Identifier Type: -
Identifier Source: org_study_id
More Related Trials