Continuous Remote Vital Sign Monitoring During Labour Analgesia With Remifentanil

NCT ID: NCT07167498

Last Updated: 2025-09-11

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Total Enrollment

80 participants

Study Classification

OBSERVATIONAL

Study Start Date

2025-11-01

Study Completion Date

2027-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Continuous remote vital sign monitoring during labour analgesia with remifentanil - a prospective observational study

Remifentanil PCA represents a well-tolerated, effective and valuable option for labour analgesia, yet its wider implementation is still limited by concerns of opioid side-effects particularly the risk of respiratory depression leading to desaturation, potentially affecting the foetus. Thus, continuous one-to-one observation and monitoring in the delivery room, with the midwife unable to leave the patient unattended, is recommended. Such constant one-to-one monitoring may be challenging in present health-care settings where staffing constraints may limit the implementation of remifentanil as routine obstetric care.

Continuous remote vital sign monitoring to display oxygen saturation (SpO₂), respiratory rate, and heart rate on a handheld device (smartphone), has the potential to address this barrier by allowing the midwife to leave the labour room for short, predefined intervals while maintaining continuous surveillance of maternal vital signs. Such an approach could free staff resources without compromising patient safety. While centralised foetal monitoring (CTG) is standard practice in many units, the application of continuous remote vital sign monitoring for women receiving remifentanil during labour has, to our knowledge, never been formally studied.

Objectives The aim is to study whether remote monitoring during remifentanil patient-controlled analgesia (PCA) for labour affects the incidence of maternal desaturation and other safety outcomes (bradypnoea, bradycardia, and neonatal outcomes, assessed via Apgar scores and umbilical cord pH.) The study will be conducted in a setting where remifentanil PCA is administered for labour analgesia and the midwife is permitted to leave the labour room for intervals of up to 10 minutes while the woman is remotely monitored using a handheld device carried by the midwife. Predefined criteria for when the woman must be accompanied (e.g., if SpO₂ \< 94%, supplemental oxygen \>2L/min., or decreased consciousness). Outcomes in this group will be compared with a control group where the midwife remains continuously present in the labour room.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Introduction Remifentanil, a potent, ultra-short-acting opioid, administered intravenously via patient-controlled analgesia (PCA) has been used for more than a decade in several countries, particularly in Switzerland and at the Ulster Hospital in Ireland. In 2024, remifentanil was formally included as a standard option for labour analgesia in the United Kingdom and incorporated into the guidelines from the National Institute for Health and Care Excellence (NICE). The REMIPCA SAFE Network collaboration has further demonstrated that remifentanil PCA is a safe and effective method for labour analgesia, offering rapid onset, patient autonomy, and high maternal satisfaction (remiPCA.org).

In many European and Anglophone countries, nitrous oxide and epidural analgesia remain the most commonly used pharmacological methods for labour analgesia, while the use of remifentanil is not yet widespread in all settings. Nitrous oxide cause nausea and is under increasing scrutiny due to environmental concerns, while epidural analgesia, although highly effective for pain relief, is more invasive, resource intensive and associated with rare but severe complications.

Remifentanil PCA represents a well-tolerated, effective and valuable option for labour analgesia, yet its wider implementation is still limited by concerns of opioid side-effects particularly the risk of respiratory depression leading to desaturation, potentially affecting the foetus. Thus, continuous one-to-one observation and monitoring in the delivery room, with the midwife unable to leave the patient unattended, is recommended. Such constant one-to-one monitoring may be challenging in present health-care settings where staffing constraints may limit the implementation of remifentanil as routine obstetric care.

Continuous remote vital sign monitoring to display oxygen saturation (SpO₂), respiratory rate, and heart rate on a handheld device (smartphone), has the potential to address this barrier by allowing the midwife to leave the labour room for short, predefined intervals while maintaining continuous surveillance of maternal vital signs. Such an approach could free staff resources without compromising patient safety. While centralised foetal monitoring (CTG) is standard practice in many units, the application of continuous remote vital sign monitoring for women receiving remifentanil during labour has, to our knowledge, never been formally studied.

Objectives The aim is to study whether remote monitoring during remifentanil for labour analgesia affects the incidence of maternal desaturation and other safety outcomes (bradypnoea, bradycardia, and neonatal outcomes, assessed via Apgar scores and umbilical cord pH.) This will be assessed in a setup where remifentanil PCA for labour analgesia is given and the midwife is allowed maximum absence intervals of 10 minutes with predefined criteria for when the woman must be accompanied (e.g., if SpO₂ \< 94%, supplemental oxygen \>2L/min., or decreased consciousness) and compared with a control group where the midwife is in the labour room continuously.

Methods

Ethics The study will be conducted in compliance with the Declaration of Helsinki. Participation will be voluntary, and written informed consent will be obtained prior to inclusion. Participants may withdraw their consent at any time without consequences for their further treatment. Approval for data collection, processing, and storage will be sought from the Data Protection Authority for the Capital Region of Denmark prior to study initiation. The National committee on health research ethics, Denmark has approved the study in accordance with Danish legislation (ID: 2203648, date: 2024-06-25). All collected data will be handled in strict confidence and anonymised prior to analysis. The study protocol will be registered at ClinicalTrials.gov before inclusion of the first patient.

Study design A single centre before and after prospective observational study. Based on maternal and neonatal physiological parameters in parturients giving birth with remifentanil PCA for labour analgesia, using continuous remote vital sign monitoring, while the attending midwife is either continuously present in the labour room (group 1) or intermittently present, with absence intervals of up to 10 minutes (group 2)

Setting Location The study will be conducted at the labour ward of North Zealand Hospital. Recruitment period Recruitment is expected to be completed between 1 October 2025 and 31 December 2026.

Data collection Continuous monitoring of oxygen saturation (SpO₂), cardiotocography (CTG), respiratory rate, and heart rate during labour will be registered for analysis. Oxygen saturation (SpO₂), respiratory rate, and heart rate will be collected using the WARD technology (WARD247 Aps, Copenhagen, Denmark) and consists of threadless body-sensors which monitor oxygen saturation (SpO₂), ECG and respiratory rate every minute. These data are then electronically transferred to the WARD monitoring application on a handheld mobile device (smartphone). The adhesive body sensors are applied using a bracelet for the wrist and two ECG electrodes on the chest allowing considerable freedom of movement. CTG will be collected with Umbilical cord pH will be measured in all participants. Additional maternal and neonatal physiological parameters will be obtained from health records from the birth admission. The midwife will register when they are absent from the labour room, including frequency and duration of absences.

Remifentanil administration for labour analgesia Remifentanil is administered as patient-controlled analgesia (PCA) via an intravenous line. When the parturient presses the PCA button, a bolus of 20 µg remifentanil (corresponding to 1 mL) is delivered; the bolus dose may be adjusted between 10 µg and 30 µg. The lockout interval is 2 minutes. Administration must be discontinued around 10 minutes prior to delivery. The parturient is monitored for oxygen saturation (SpO₂), respiratory rate, cardiotocography (CTG), and heart rate. Each parturient will receive one-to-one midwifery care, as is standard practice in Denmark. The use of labour analgesia will be adapted to the individual course of labour, and medical pain management during active labour may include nitrous oxide, remifentanil, and epidural analgesia.

In the department's standard operating procedure, adapted from remipca.org, the target oxygen saturation (SpO₂) during the use of remifentanil is \> 93%. If SpO₂ is \< 94% for more than two minutes supplemental oxygen should be administered, either via face mask for short desaturation episodes or via nasal cannula.

When the parturients are receiving remifentanil for labour analgesia in the study protokol:

Group 1: The midwife stays in the labour room Group 2: the midwife is permitted to leave the labour room for intervals of up to 10 minutes while carrying a personal handheld device that displays continuous SpO₂, respiratory rate, and heart rate for remote monitoring. The monitoring system presents SpO₂, HR and RR continuously on the screen (updated every minute), and the midwife is responsible for continuous observation via the remote monitoring system and must respond immediately if SpO₂ falls below 94% or RR are below 10. As a safety precaution, an alarm is triggered after 10 minutes if SpO2 falls below 88%, after 5 minutes if SpO₂ falls below 85%, and immediately if SpO₂ falls below 80% and immediately if RR falls to ≤5 brpm.

The midwife is only permitted to leave the labour room if the parturient receiving remifentanil is awake, responsive, and accompanied by a partner who is capable and instructed to call for assistance if SpO₂ drops below 94% or if the parturient becomes unconscious. CTG will be centrally monitored at the ward level by the ward responsible midwife, who maintains an overview of CTG tracings from all delivery rooms.

As an extra safety precaution during this study, the ward-responsible midwife will also be informed if the attending midwife leaves the room and will be able to monitor the SpO₂ together with the CTG via the central monitoring system connected to all delivery rooms.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Labor Pain

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Group 1: The midwife stays in the labour room during remifentanil PCA for labour analgesia

Group 1: The midwife stays in the labour room while the parturient are having remifentanil for labour analgesia.

Intermittent midwife absence during remote monitoring of remifentanil PCA in labour

Intervention Type BEHAVIORAL

Midwife absence during remifentanil PCA for labour analgesia.

We aim to include a total of 80 participants. All will receive remifentanil PCA for labour analgesia and be monitored with remote monitoring equipment. First a group of 40 parturients will be included, and the attending midwife will not be allowed to leave the parturient (Group 1). A following group of 40 parturients will then be included and the attending midwife can leave the room in intervals up to 10 minutes (Group 2).

Group 2: The midwife can leave the labour room during remifentanil PCA for labour analgesia

Group 2: the midwife is permitted to leave the labour room for intervals of up to 10 minutes while carrying a personal handheld device that displays continuous SpO₂, respiratory rate, and heart rate for remote monitoring.

Intermittent midwife absence during remote monitoring of remifentanil PCA in labour

Intervention Type BEHAVIORAL

Midwife absence during remifentanil PCA for labour analgesia.

We aim to include a total of 80 participants. All will receive remifentanil PCA for labour analgesia and be monitored with remote monitoring equipment. First a group of 40 parturients will be included, and the attending midwife will not be allowed to leave the parturient (Group 1). A following group of 40 parturients will then be included and the attending midwife can leave the room in intervals up to 10 minutes (Group 2).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Intermittent midwife absence during remote monitoring of remifentanil PCA in labour

Midwife absence during remifentanil PCA for labour analgesia.

We aim to include a total of 80 participants. All will receive remifentanil PCA for labour analgesia and be monitored with remote monitoring equipment. First a group of 40 parturients will be included, and the attending midwife will not be allowed to leave the parturient (Group 1). A following group of 40 parturients will then be included and the attending midwife can leave the room in intervals up to 10 minutes (Group 2).

Intervention Type BEHAVIORAL

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Minimum 18 years of age
* Able to provide written informed consent
* Giving birth to a singleton, cephalic presenting, expected healthy child, gestational age \> 37 weeks.
* In active labour

Exclusion Criteria

* Respiratory or cardiac disease
* BMI ≥ 40 Other opioids within the last 4 hours.
Minimum Eligible Age

18 Years

Maximum Eligible Age

50 Years

Eligible Sex

FEMALE

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Nordsjaellands Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Patricia Duch

Consultant, MD

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Patricia Duch, MD

Role: PRINCIPAL_INVESTIGATOR

Nordsjaellands Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University Hospital of Copenhagen, Northern Zealand

Hillerød, , Denmark

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Denmark

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Patricia Duch, MD

Role: CONTACT

+45 48292504

Laura Fugmann, Cand. Soc

Role: CONTACT

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

104

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.