Clinical Application Research of 5-Degree (0.05 D) Precision Optometry in Corneal Refractive Surgery

NCT ID: NCT07146828

Last Updated: 2025-08-28

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

600 participants

Study Classification

INTERVENTIONAL

Study Start Date

2025-01-01

Study Completion Date

2026-10-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

In recent years, the incidence of myopia has been high globally and is exhibiting a rapid upward trend, with projections estimating it will reach 49.8% by 2050. Corneal refractive surgery has become a primary method for correcting myopia, demonstrating significant efficacy and favorable safety. However, studies indicate that overcorrection or undercorrection can occur following refractive surgery. Reports have shown that three months post-SMILE surgery, 20% of eyes had residual refractive errors ≥ 0.50 D, and 6% had errors ≥ 1.00 D. We hypothesize that this may be related to imprecise preoperative refraction, subsequently affecting postoperative visual quality.

Due to limitations in lens manufacturing precision, the widely used increment for sphere correction remains 0.25 D. However, this may prevent some patients from achieving their optimal corrected state. Studies have reported that 95% of individuals are sensitive to diopter changes below 0.25 D, and 44% can distinguish changes smaller than 0.125 D. Other research suggests that adjusting spherical power in 0.05 D increments yields better corrected visual acuity. Furthermore, scholars have reported that 0.05 D precision refraction can significantly improve the red-green balance test rate, enabling myopic patients to achieve better visual quality. Therefore, improving refraction precision could provide patients with superior visual outcomes.

Currently, the Binocular Wavefront Optometry Machine (BWFOM, Ai-Zhitong Medical Technology Co., Ltd., Zhejiang, China) can perform objective and subjective refraction with 0.05 D increments for both sphere and cylinder correction, while also separately measuring higher-order aberrations (HOAs) and lower-order aberrations (LOAs). Given the scarcity of research on the outcomes of 0.05 D refraction for SMILE and FS-LASIK procedures, this study aims to evaluate visual acuity, aberrations, and refractive status in patients following SMILE and FS-LASIK surgery. The primary objective is to investigate whether preoperative 0.05 D precision refraction using the BWFOM can enhance postoperative visual quality for SMILE and FS-LASIK patients.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study aims to optimize the surgical parameters of corneal refractive surgery (SMILE and FS-LASIK) by utilizing 0.05 D high-precision refraction achieved through a binocular wavefront aberrometer, thereby improving patients' postoperative visual outcomes. The prospective study design involves patients scheduled for corneal refractive surgery at our hospital.

The research consists of two parts:

Part One: Performing 0.05 D precision refraction on myopic patients using the binocular wavefront aberrometer.

Part Two: Applying the obtained refraction results (in increments of 0.05 D) for refractive correction in patients undergoing SMILE and FS-LASIK surgery.

Specific procedures include:

Screening eligible patients who voluntarily choose SMILE or FS-LASIK. Preoperatively inputting the patients' 0.05 D refraction data into the SMILE platform (VisuMax Precision 4.0 - VISULYZE system) or the FS-LASIK system (applying the manufacturer-provided nomogram for undercorrection).

Utilizing the system-recommended input values for correcting refractive errors during surgery.

Conducting postoperative follow-up examinations at 10 days, 1 month, 3 months, 6 months, and 1 year.

Evaluation metrics include:

1. Primary Endpoint Indicators:

Postoperative uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), spherical power, cylindrical power, spherical equivalent (SE), and aberrations.

Proportion of patients achieving postoperative UCVA ≥ 0.8, ≥ 1.0, and ≥ 1.2. Proportion of patients with postoperative SE within ±0.50 D and ±1.0 D. Proportion of patients with postoperative astigmatism (cylinder) within ±0.50 D and ±1.0 D.

Postoperative efficacy index and safety index.
2. Safety Indicators:

Intraocular pressure (IOP). Anterior segment examination.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Refractive Surgery

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

TRIPLE

Participants Caregivers Investigators

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

traditional group

The traditional group had their infusion rates based on past experience.

Group Type NO_INTERVENTION

No interventions assigned to this group

0.05 D refraction Group

The 0.05 D refraction group had their infusion rates precisely calibrated using 0.05 D refraction by the Binocular Wavefront Optometry Machine (BWFOM, Ai-Zhitong Medical Technology Co., Ltd., Zhejiang, China)

Group Type EXPERIMENTAL

Binocular Wavefront Optometry Machine (BWFOM, Ai-Zhitong Medical Technology Co., Ltd., Zhejiang, China)

Intervention Type DEVICE

The 0.05 D refraction group had their infusion rates precisely calibrated using 0.05 D refraction by the Binocular Wavefront Optometry Machine

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Binocular Wavefront Optometry Machine (BWFOM, Ai-Zhitong Medical Technology Co., Ltd., Zhejiang, China)

The 0.05 D refraction group had their infusion rates precisely calibrated using 0.05 D refraction by the Binocular Wavefront Optometry Machine

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. The diopter is relatively stable (the diopter increases within -0.50D per year for 2 consecutive years);
2. Age: 18 to 40 years old;
3. Optimal preoperative corrected visual acuity \>= 4.8;
4. More than 2 weeks for soft contact lenses and more than 3 months for hard contact lenses before surgery
5. Patients who are willing to perform SMILE surgery

Exclusion Criteria

1. Patients with history of eye surgery and trauma;
2. Patients with keratoconus tendency;
3. systemic connective tissue diseases and autoimmune diseases;
4. Patients with high blood pressure, diabetes and heart disease history;
5. Other eye disease history such as uveitis, scleritis and other eye inflammation patients;
6. Patients with scar constitution.
Minimum Eligible Age

18 Years

Maximum Eligible Age

40 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Affiliated Hospital of Nantong University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Binocular Wavefront Optometry Machine

Nantong, Jiangsu, China

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

China

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Ying Yu, MD

Role: CONTACT

+86 159 9662 1616

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

enze Liu, MD

Role: primary

+86 15233615173

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2025-K173

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

The Berkeley Orthokeratology Study
NCT00000123 COMPLETED PHASE3
Myopia Prevention With Reading Glasses
NCT05030103 NOT_YET_RECRUITING NA
Early Intervention for Premyopic Children
NCT06200194 ACTIVE_NOT_RECRUITING PHASE2
Wuhan High Myopia Study
NCT06162234 RECRUITING