Upper Eyelid Dynamics in Pediatric Blepharoptosis Using High Speed Videography

NCT ID: NCT06976645

Last Updated: 2025-05-16

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2025-07-01

Study Completion Date

2026-07-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Evaluation of the Upper Eyelid Dynamics in Simple Congenital Blepharoptosis before and after Levator Muscle Resection Using High speed Photography

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Normal eyelid dynamics are essential for optimum performance and protection of the eye including distribution of the pre-corneal tear film, clearance of debris, stimulation of Meibomian gland secretion, and assistance of tear drainage via generating negative pressure in the lacrimal sac. Conversely, abnormal eyelid dynamics can have a variety of implications in ocular surface health and visual function.1 Current methods for evaluating eyelid dynamics include magnetic-based devices, high-speed videography, infrared videography, and direct observation.2-3 Whereas magnetic search coils are considered the gold standard for research purposes, they may not be practical at the clinical setting. Conversely, a readily available and cost-effective technology of smartphone video cameras with high speed video photography options has reached a level of perfection that may enable them to be used for objective and quantative slow motion analysis of eyelid dynamics.

The interest in the study of lid dynamics started early in 1977 through dynamic measurements made with a mechanical transducer connected physically to the upper eyelid. 4 The normal spontaneous blink rate has a wide variability, ranging from 2 to 50 blinks per minute. It is reported that normal blink duration varies from 300 to 572 milliseconds. Normal blink amplitudes also vary from 7.4 to 12.8 mm and decrease with age.5-6,7-8 Most of these values have been established with different techniques for analysis with magnetic search coil.6,7,9 High-speed cameras provide precise, measurable movement detection.9 With these cameras, the upper and lower eyelids have shown to both move also horizontally during the closure phase of eyelid blinking.7 Previous studies measured the spontaneous eyelid blink dynamic changes using a high-speed camera in various conditions as age-related changes5, following upper eyelid blepharoplasty and its association with dry eye10 and in patients with thyroid disease11.

Upper eyelid surgery can change the lid dynamics. For instance, incomplete lid closure is sometimes encountered after upper blepharoplasty. The most common cause of lagophthalmos is excessive skin resection, which acts as a negative passive force that is much stronger than the active closing force of the orbicularis oculi muscle and can disturb blinking .12 Congenital ptosis is the presence of an abnormally low position of the upper eyelid, with respect to the visual axis in the primary gaze .13 It may not be immediately noticeable after birth but is usually manifest within a few months. It can be unilateral or bilateral. It has a significant functional and psychosocial impact on the child.14The underlying etiology appears to be localized muscle dysgenesis. In the affected levator muscle fibers are infiltrated or replaced with fibrous and adipose tissue, which results in abnormal contraction and relaxation .15 There is an association between congenital ptosis and under action of the superior rectus muscle in up to 25% of unilateral cases and in 65% of bilateral cases .16 It may be associated with lagophthalmos on downgaze with exposure of the cornea. There is often a decreased or absent lid crease .13 Levator resection is the gold standard of surgical correction of simple congenital ptosis with fair to good levator function. It creates optimal lid contour and symmetry with relatively desirable cosmetic outcomes17-19. Lagophthalmos is one of the surgical consequences. It usually improves with time .20 In the study of Cruz et al.,2014 21 on supramaximal levator resection, spontaneous blinks were abnormal in 93% of the operated eyelids. The mean amplitude of the abnormal blinks was 37.1% of the contralateral eyelids. Downward eyelid saccades were reduced in 79% of the eyelids.

To the best of our knowledge this is the first study to assess the changes of eyelid dynamics in patients with simple congenital ptosis before and after levator muscle resection using high speed video photography. Aim of the study

Quantative subjective analysis of upper eyelid dynamics in patients with simple congenital ptosis before and after levator muscle resection using high speed video recording.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Upper Eyelid Dynamics

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Levatot muscle resection

Levator muscle resection for correction of upper eyelid congenital blepharoptosis

Group Type OTHER

Levator muscle resection

Intervention Type PROCEDURE

Levator muscle resection

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Levator muscle resection

Levator muscle resection

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients who are diagnosed as simple congenital ptosis with fair to good levator function (≥5 mm lid elevation) with age range from 5 to 18 years old.

Exclusion Criteria

* Patients with a history of previous eyelid surgery or trauma

* Blepharophamosis and Marcus Gun Jaw-winking syndrome
* Patients with associated neurological disorders
* Patients with craniofacial abnormalities
* Patients with suspected myasthenia or myopathies
* Patients with absent Bell's phenomenon
* Patients with dry eye
* Uncooperative patients
Minimum Eligible Age

5 Years

Maximum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Minia University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Zamzam Mohamed Alham

Assistant lecturer

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ahmed Mohamed Elshafei, Professor

Role: STUDY_DIRECTOR

Minia University

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Zamzam Mohamed Alham, Assistant lecturer

Role: CONTACT

+201016909914 ext. +201224222252

References

Explore related publications, articles, or registry entries linked to this study.

Hung G, Hsu F, Stark L. Dynamics of the human eyeblink. Am J Optom Physiol Opt. 1977 Oct;54(10):678-90. doi: 10.1097/00006324-197710000-00005.

Reference Type BACKGROUND
PMID: 605924 (View on PubMed)

DeAngelis KD, Rider A, Potter W, Jensen J, Fowler BT, Fleming JC. Eyelid Spontaneous Blink Analysis and Age-Related Changes Through High-Speed Imaging. Ophthalmic Plast Reconstr Surg. 2019 Sep/Oct;35(5):487-490. doi: 10.1097/IOP.0000000000001349.

Reference Type BACKGROUND
PMID: 30844914 (View on PubMed)

Mak FHW, Ting M, Edmunds MR, Harker A, Edirisinghe M, Duggineni S, Murta F, Ezra DG. Videographic Analysis of Blink Dynamics following Upper Eyelid Blepharoplasty and Its Association with Dry Eye. Plast Reconstr Surg Glob Open. 2020 Jul 21;8(7):e2991. doi: 10.1097/GOX.0000000000002991. eCollection 2020 Jul.

Reference Type BACKGROUND
PMID: 32802679 (View on PubMed)

Wuthisiri W, Peou C, Lekskul A, Chokthaweesak W. Maximal Levator Resection Beyond Whitnall's Ligament in Severe Simple Congenital Ptosis with Poor Levator Function. Clin Ophthalmol. 2022 Feb 17;16:441-452. doi: 10.2147/OPTH.S340781. eCollection 2022.

Reference Type BACKGROUND
PMID: 35210749 (View on PubMed)

Allard FD, Durairaj VD. Current techniques in surgical correction of congenital ptosis. Middle East Afr J Ophthalmol. 2010 Apr;17(2):129-33. doi: 10.4103/0974-9233.63073.

Reference Type BACKGROUND
PMID: 20616918 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

UEL dynamics in cong.ptosis

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Improving Control of Intermittent Exotropia
NCT07272005 NOT_YET_RECRUITING NA
Patch-free Occlusion Therapy
NCT05440448 RECRUITING NA