Prophylactic Suture Line Sealing With NE'X Glue R-eco in Cardiac and Vascular Surgery

NCT ID: NCT06918496

Last Updated: 2025-04-09

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2025-06-30

Study Completion Date

2026-03-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This clinical study aims to evaluate the effectiveness and safety of using NE'X Glue R-eco to seal suture lines. The adhesive will be applied to reduce the risk of suture line bleeding in cardiac or vascular repair surgeries, a prosthetic or biologic graft, patch, or allograft.

The effectiveness of the adhesive will be assessed after restoring blood flow.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Suture line bleeding is a common issue in cardiovascular surgeries, leading to serious complications and increased costs. Effective management is crucial to prevent morbidity, fatal consequences, and the need for reoperation, which has high mortality rates. Blood transfusions carry risks, and patients who avoid them tend to recover better. Advances in surgical techniques and the use of anticoagulants have increased the need for robust methods to prevent suture line bleeding.

Surgical adhesives are becoming standard practice to prevent air and liquid leaks during surgeries. Different classes of adhesives, such as cyanoacrylates, polyethylene glycol polymers, bovine serum albumin (BSA) and glutaraldehyde mixtures, gelatin and thrombin sealants, and fibrin sealants, offer various advantages and disadvantages.

Most cyanoacrylate sealants are used externally due to risks of infection, cytotoxicity, and tissue necrosis when used internally. They are effective for closing skin incisions, trauma wounds, and providing a microbial barrier over closed wounds. Polyethylene glycol hydrogel adhesives are valued for their biocompatibility, degradability, and tunable mechanical properties, acting as both fluid barriers and hemostatic agents. However, they can cause significant post-polymerization swelling. Fibrin sealants, derived from blood, are used as hemostatic agents in cardiac, liver, and splenic surgeries. They carry risks of transmitting infections and air or gas embolism. Gelatin and thrombin mixtures are versatile hemostatic agents used in various surgeries, including delicate structures like nerves, due to their low toxicity.

The last class of surgical adhesives includes mixtures of bovine serum albumin (BSA) and glutaraldehyde (GA) or polyaldehyde. In BioGlue® (CryoLife Inc.) and PREVELEAKTM (Baxter Advanced Surgery), BSA crosslinks with extracellular proteins to form a mechanical seal independent of the coagulation system. NE'X Glue R-eco, a new adhesive by Grena BioMed Limited, is similar to BioGlue® but uses recombinant human serum albumin (rHSA) instead of BSA. Both adhesives use a double-chambered syringe for controlled application.

BioGlue® has proven biocompatibility, reliability, and safety, with minor differences in external shape compared to NE'X Glue R-eco. BioGlue® has passed extensive biological evaluations and animal studies, demonstrating its effectiveness in surgical repairs.

Analytical and functional tests have shown that NE'X Glue R-eco has adequate bonding strength and similar chemical properties to BioGlue®. The safety and benefits of these adhesives have been demonstrated in various studies. This pivotal study aims to evaluate the efficacy and safety of NE'X Glue R-eco for sealing suture lines. The study will assess immediate and delayed suture line sealing, sealing time, use of additional agents, product handling, blood loss, use of blood replacement products, anticoagulant/antiplatelet medication intake, device deficiencies, and peri- and postoperative complications and re-interventions.

The primary objective of this study is to evaluate the immediate sealing of suture lines using NE'X Glue R-eco. The secondary objective is to assess the overall efficacy and safety of NE'X Glue R-eco for prophylactic suture line sealing.

This clinical investigation uses a single-arm, non-randomized design to evaluate the safety and effectiveness of surgical adhesives in cardiac and vascular procedures. Strict inclusion and exclusion criteria prevent bias, ensuring participants represent the general population needing these surgeries. Exclusion criteria include hypersensitivity, active infection, vasculitis, bleeding disorders, immune suppression, and refusal of blood transfusions. Clinical Research Associates will monitor the study and report any deviations.

Participants will be followed for up to 3 months post-surgery to document potential complications such as inflammatory responses, allergic reactions, tissue necrosis, vessel obstruction, thrombosis, and more. This follow-up period allows for clear documentation of safety and effectiveness.

Patients undergoing large vessel and cardiac repair, arterial reconstruction, or arteriovenous graft formation with prosthetic or biologic grafts (patches) or allografts will be included in this study. Data will be collected from 60 patients at sites in Belgium and Poland. Inclusion and exclusion criteria ensure a diverse participant cohort reflective of the broader population. Minors, pregnant women, and breastfeeding women are excluded. Female participants of childbearing age must use contraception and undergo pregnancy testing. Incapacitated patients may be included if their medical condition prevents informed consent. Follow-up monitoring will be conducted for up to 3 months post-procedure.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Aortic Aneurysm Aortic Aneurysm Abdominal Valve Stenoses, Aortic Valve Regurgitation, Mitral Valve Regurgitation, Tricuspid Aneurysm of Ascending Aorta Aneurysm Abdominal Artery Diseases, Peripheral Ventricular Aneurysm Coronary Artery Disease Valve Aortic Regurgitation Aortic Aneurysms Arch Aortic Aneurysms Descending Aortic Aneurysms Thoracoabdominal

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Pre-market, pivotal, commercial, prospective, single-arm, interventional, multicenter clinical investigation
Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Single-arm

A single-arm design is selected, providing data about safety and clinical effectiveness of the NE'X Glue R-eco of which are to be compared to established data available in the literature

Group Type EXPERIMENTAL

Surgical placement of a prosthetic or biologic graft (patch), or an allograft for cardiac and (cardio)vascular repair.

Intervention Type DEVICE

Suture line bleeding in cardiac and vascular reconstruction poses significant risks, including morbidity, mortality, and complications related to blood loss and transfusion. Advances in surgical techniques have improved hemostasis but may not suffice, especially in patients on anticoagulant or antiplatelet medications or those using synthetic graft materials.

Surgical adhesives are valuable adjuncts to standard hemostatic techniques, aiming to prevent postoperative bleeding and its associated complications. NE'X Glue R-eco, a novel surgical adhesive, utilizes recombinant human serum albumin (rHSA) and glutaraldehyde (GA) for suture line sealing. It is similar to BioGlue®, which uses bovine serum albumin (BSA) and GA, and has proven safety and benefits.

Distinguishing Features of NE'X Glue R-eco:

Composition: Uses rHSA expressed in plants, offering improved biocompatibility and reduced risk of allergic reactions.

Bonding Strength: Demonstrates high bonding strength in tests, comparab

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Surgical placement of a prosthetic or biologic graft (patch), or an allograft for cardiac and (cardio)vascular repair.

Suture line bleeding in cardiac and vascular reconstruction poses significant risks, including morbidity, mortality, and complications related to blood loss and transfusion. Advances in surgical techniques have improved hemostasis but may not suffice, especially in patients on anticoagulant or antiplatelet medications or those using synthetic graft materials.

Surgical adhesives are valuable adjuncts to standard hemostatic techniques, aiming to prevent postoperative bleeding and its associated complications. NE'X Glue R-eco, a novel surgical adhesive, utilizes recombinant human serum albumin (rHSA) and glutaraldehyde (GA) for suture line sealing. It is similar to BioGlue®, which uses bovine serum albumin (BSA) and GA, and has proven safety and benefits.

Distinguishing Features of NE'X Glue R-eco:

Composition: Uses rHSA expressed in plants, offering improved biocompatibility and reduced risk of allergic reactions.

Bonding Strength: Demonstrates high bonding strength in tests, comparab

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patient ≥ 18 years of age at study entry.
* Patient is scheduled for open procedures for surgical placement of a prosthetic or biologic graft (patch) or an allograft for cardiac and (cardio)vascular anastomosis repair. Emergency, transplantation and minimally invasive procedures are excluded. Patients receiving long-term anticoagulation, including antiplatelet agent, are included. Choice of graft is at the discretion of the surgeon.
* Patient is willing and able to be contacted for up to 3 months (± 14 days) follow-up.
* Patient or legal representative and investigator signed and dated the informed consent form prior to the index-procedure.

Exclusion Criteria

* Patient has a known hypersensitivity, contraindication, or allergic reaction to albumin or glutaraldehyde.
* Patient has a history of bleeding diathesis or coagulopathy.
* Presence of active infection or contamination in the to be grafted area or the vicinity.
* Known vasculitis in the to be grafted area.
* Patient takes immune suppressive medication like prednisone resulting in weakening of the vessel wall.
* Patient is refusing blood transfusion.
* Patient or legal representative is unable / unwilling to provide informed consent.
* Patient is unable to comply with the protocol or proposed follow-up visits.
* Female patient is pregnant, lactating, or planning pregnancy during the clinical investigation.
* Female participants of childbearing age must agree to use safe contraception (e.g., intrauterine devices, hormonal contraceptives: contraceptive pills, implants, transdermal patches hormonal vaginal devices, injections with prolonged release, abstinence).
* Patients who are currently enrolled in another clinical study, or have recently participated in a clinical study, that could potentially interfere with the outcomes or introduce bias into the results of the current study (as determined by the investigator). This includes studies involving investigational drugs, medical devices, or other interventions that could impact the safety, efficacy, or scientific integrity of this study.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Archer Research

INDUSTRY

Sponsor Role collaborator

Grena Biomed Limited

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Jessa Hospital

Hasselt, Limburg, Belgium

Site Status

Klinika Kardiochirurgii i Transplantologii

Warsaw, , Poland

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Belgium Poland

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Dorien Haesen, PhD

Role: CONTACT

+32 11 286927

Frea Coun

Role: CONTACT

+32 11 286927

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Dr. Bert Du Pont

Role: primary

Dr. Piotr Kołsut

Role: primary

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CIV-24-12-050294

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

AneuFix - Prophylactic Sac Filling
NCT04307992 RECRUITING NA
Branched Aortic Arch Study
NCT00488696 WITHDRAWN NA
Preoperative BNP and MINS in AAA Open Repair
NCT06088641 ACTIVE_NOT_RECRUITING