This Study Evaluates the Impact of the Sodium Management Tool (SMT) on Hemodialysis Patient Outcomes Compared to Standard Care

NCT ID: NCT06896786

Last Updated: 2025-03-26

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

30 participants

Study Classification

INTERVENTIONAL

Study Start Date

2025-04-01

Study Completion Date

2025-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Title of the Study: Sodium Management Tool in Hemodialysis Patients

Brief Summary:

The goal of this clinical trial is to learn whether the Sodium Management Tool (SMT) can improve patients clnical outcomes.

The main questions this study aims to answer are:

Does the SMT help reduce weight gain between dialysis sessions? Does the SMT improve dialysis tolerance by reducing symptoms like low blood pressure and muscle cramps?

Researchers will compare standard dialysis to dialysis using the SMT to see if clinical outcomes are better in dialysis that use the SMT.

Participants will:

Receive dialysis three times per week with either standard dialysis or SMT-activated dialysis Switch between standard dialysis and SMT-activated dialysis after 4 weeks Have their blood pressure, sodium levels, and symptoms monitored during treatment Report their symptoms and thirst levels in a questionnaire Some participants may continue for an additional 4 weeks with a personalized SMT setting based on their symptoms and weight changes.

This study will help determine whether the SMT can improve sodium balance and make dialysis more comfortable for patients.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Title of the Study: Sodium Management Tool in Hemodialysis Patients

Objectives This study aims to evaluate the impact of the Sodium Management Tool (SMT) by Fresenius on interdialytic weight gain and dialysis tolerance in hemodialysis patients. While the SMT is already in use across various dialysis centers, there is currently no systematic data collection regarding its clinical benefits.

In conventional hemodialysis, a fixed dialysate sodium concentration (typically 136-138 mmol/L) is used without adjustments during dialysis. If the dialysate sodium concentration is higher than the plasma sodium level, sodium can diffuse into the patient, leading to increased thirst and interdialytic weight gain. These factors are associated with higher mortality and an increased risk of cardiovascular events. Conversely, a negative sodium balance (dialysate sodium concentration lower than plasma sodium) can reduce plasma tonicity, increasing the risk of muscle cramps and intradialytic hypotension.

The SMT continuously measures plasma sodium concentration (once per minute) and adjusts the dialysate sodium concentration. This optimization of sodium homeostasis may reduce the occurrence of muscle cramps and hypotensive episodes during dialysis.

Methods The study will include all outpatient hemodialysis patients from the Lucerne Cantonal Hospital at the Luzern, Luzern Süd, and Sursee sites who undergo dialysis three times per week with Fresenius 6008 machines and have provided informed consent.

Participants will be randomized into two groups:

Group 1: Standard dialysis procedure in weeks 1-4, followed by dialysis with the SMT activated in weeks 5-8. The SMT will be set to 0 mmol/L, meaning the dialysate sodium concentration will be adjusted so that the plasma sodium level at the end of dialysis matches the pre-dialysis level.

Group 2: Dialysis with the SMT activated (Na 0 mmol/L) in weeks 1-4, followed by standard dialysis in weeks 5-8.

Data collection includes:

Interdialytic weight gain Pre- and post-dialysis plasma sodium levels Blood pressure before and after dialysis Bolus administration and total sodium removal Symptomatic hypotension, blood pressure drops \>20 mmHg, and muscle cramps (documented by nursing staff) Dialysis tolerance and thirst perception, assessed using a visual analog scale (VAS) Patient-reported symptoms (thirst, shortness of breath, muscle cramps, dizziness, fatigue) using the Dialysis Symptom Index Extension Phase (Weeks 9-12)

For a subset of participants, the study will continue:

Subgroup A: Patients with high interdialytic weight gain will have the SMT set to -1 mmol/L. This setting aims for a plasma sodium level 1 mmol/L lower at the end of dialysis, enhancing sodium removal.

Subgroup B: Patients frequently experiencing symptoms (cramps, hypotension) will have the SMT set to +1 mmol/L. This adjustment targets a plasma sodium level 1 mmol/L higher at the end of dialysis, increasing plasma tonicity.

Outcomes Primary Outcome: Effect of the SMT on interdialytic weight gain. Secondary Outcomes: Incidence of intradialytic hypotension, muscle cramps, and specific patient symptoms (thirst, fatigue, shortness of breath, muscle cramps) measured using the Dialysis Symptom Index.

The study will be conducted in accordance with the Declaration of Helsinki and the International Conference on Harmonization (ICH-GCP) guidelines for Good Clinical Practice. All participants will provide written informed consent. Confidentiality and data protection will be maintained at all times.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hemodialysis Interdialytic Weight Gain Intradialytic Hypotension

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

randomised, cross over , single site design
Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Standard of care

dialysis conducted with standard of care

Group Type NO_INTERVENTION

No interventions assigned to this group

dialysis assisted with the sodium management tool

dialysis assisted with the sodium management tool

Group Type ACTIVE_COMPARATOR

dialysis assisted with the sodium management tool

Intervention Type OTHER

Sodium management tool is a modul of the fresenius 6008 dialysis machine. This model approximates changes in plasma electrolyte concentrations during dialysis and allows the estimation of sodium concentration based on dialysate conductivity. Na control biosensor continuously (every minute) monitors the dialysate side sodium balance based on measurements of fresh and spent dialysate conductivities and the application of a kinetic model to account for the typical influence of other ions on dialysate conductivity. In activated Na control, as "zero diffusive" mode, dialysate sodium is then adjusted continuously to minimize diffusive Na transfer. SMT is part of the 6008 Machine and its certification is included in the Fresenius 6008 Machine certification. Untill now there is no data if this modul benefits. in this study the investigator compares standard of care dialysis (Arm 1) with dialysis assisted with the SMT (Arm ) on clinical outcome

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

dialysis assisted with the sodium management tool

Sodium management tool is a modul of the fresenius 6008 dialysis machine. This model approximates changes in plasma electrolyte concentrations during dialysis and allows the estimation of sodium concentration based on dialysate conductivity. Na control biosensor continuously (every minute) monitors the dialysate side sodium balance based on measurements of fresh and spent dialysate conductivities and the application of a kinetic model to account for the typical influence of other ions on dialysate conductivity. In activated Na control, as "zero diffusive" mode, dialysate sodium is then adjusted continuously to minimize diffusive Na transfer. SMT is part of the 6008 Machine and its certification is included in the Fresenius 6008 Machine certification. Untill now there is no data if this modul benefits. in this study the investigator compares standard of care dialysis (Arm 1) with dialysis assisted with the SMT (Arm ) on clinical outcome

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Outpatients on hemodialysis for at least three months,
* Dialysis three times a week, age \>/= 18,
* dialysis with a Fresenius 6008 Machine,
* signed informed consent

Exclusion:

* Dialysis access with repeated Interruption due to flow problems
* plasma natrium \< 130 mmol/l, \> 145 mmol/l, pregnancy -
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Sharon-Rose Maloney

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Sharon-Rose Maloney

MD

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Balthasar Hug, Professor

Role: PRINCIPAL_INVESTIGATOR

LUKS Luzern

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Sharon-Rose Maloney, MD

Role: CONTACT

+41 412055150

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

NEP-LU-0001

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Dialysate Sodium Lowering Trial
NCT03144817 COMPLETED PHASE2
Prophylactic Antimicrobial Catheter Lock
NCT00571259 COMPLETED PHASE4
Weight Management of Dialysis Patients
NCT06333574 NOT_YET_RECRUITING NA
Resistance Exercise in Hemodialysis Patients
NCT06604221 NOT_YET_RECRUITING NA
Symptom Monitoring in Hemodialysis
NCT05738330 RECRUITING NA