Feasibility of Valve-in-Root Transcatheter Aortic Valve Implantation in 363 Patients After Aortic Root Replacement and Repair
NCT ID: NCT06697249
Last Updated: 2024-11-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
760 participants
OBSERVATIONAL
2024-01-10
2024-06-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The minimally invasive implantation of transcatheter valves has proven to be a successful method, avoiding a second operation with an increased risk of mortality. The so-called valve-in-valve procedures are carried out particularly in older patients and are now standard in modern valve treatment. The feasibility of a valve-in-valve in the aortic position requires certain anatomical conditions, which can be influenced by the surgeon's implantation technique in the case of additional root replacement. In particular, there is a risk of coronary artery occlusion when implanting the transcatheter valve, which is increased if the coronary artery branches are located below the valve level. In addition, the selection of the prosthesis size is an important parameter for subsequently implanting a suitably large transcatheter valve.
The aim of this study is to use postoperative computer tomography of patients after root replacement/reconstruction to measure the anatomical parameters that describe a possible implantation of a transcatheter valve in the event of degeneration of the initial valve. This simultaneously shows the quality of the root replacement/reconstruction with regard to a plannable follow-up procedure and can also show for the future how the surgical technique could be modified to make a minimally invasive follow-up intervention available to more patients.
This study aims to answer the question of whether the patients who were treated with biological root replacement or reconstruction in the years 2012-2022 for aortic valve failure are anatomically suitable for valve-in-valve therapy based on the postoperative computed tomography measurements of the aortic root. In addition, the measurements provide a surgical answer to the question of whether relevant parameters such as the distance between the coronary arteries were sufficiently taken into account during the initial operation or whether an improvement should be made in the future while adhering to the anatomically important parameters during the initial procedure.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Coronary and Structural Interventions - Transcatheter Aortic Valve Replacement
NCT02162069
Treatment of Concomitant Mitral Regurgitation by Mitral Valve Clipping in Patients With Successful Transcatheter Aortic Valve Implantation.
NCT04009434
Everyday Practice With Transcatheter Aortic Valve Implantation
NCT02289339
Aortic Valve replAcement in eLective Patients From aOrtic Valve multiceNter Registry
NCT05308173
Multi Modal Cardiac Imaging Prior Transcatheter Aortic Valve Implantation
NCT01805739
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CONTROL
RETROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
RR patients
Patients after biological aortic root replacement
Analysis of postoperative CT scans checking for the feasibility of transcatheter valve-in-root implantation
CT scans of patients after biological root replacement and root repair were assessed with the 3mensio Software (Aortic valve package, 3mensio 10.1, Pie Medical Imaging. Before carrying out the measurements, markers for alignment of the aortic root and ascending aorta were placed manually. The annular area was measured for both groups. In patients after biological root replacement the area of the annulus was defined as the ring of the initial aortic valve prosthesis. Coronary buttons were measured at their lowest and highest point to define partial or full position below the valve level and the general button size. For assessment of the annular-to-coronary distance, the lower edge of the coronary button was chosen. VTC was assessed after root replacement in patients who had at least one coronary partially under the level of the valve. For this measurement a virtually inserted valve was placed in the bioprosthetic frame.
VSRR patients
Patients after valve-sparing aortic root replacement
Analysis of postoperative CT scans checking for the feasibility of transcatheter valve-in-root implantation
CT scans of patients after biological root replacement and root repair were assessed with the 3mensio Software (Aortic valve package, 3mensio 10.1, Pie Medical Imaging. Before carrying out the measurements, markers for alignment of the aortic root and ascending aorta were placed manually. The annular area was measured for both groups. In patients after biological root replacement the area of the annulus was defined as the ring of the initial aortic valve prosthesis. Coronary buttons were measured at their lowest and highest point to define partial or full position below the valve level and the general button size. For assessment of the annular-to-coronary distance, the lower edge of the coronary button was chosen. VTC was assessed after root replacement in patients who had at least one coronary partially under the level of the valve. For this measurement a virtually inserted valve was placed in the bioprosthetic frame.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Analysis of postoperative CT scans checking for the feasibility of transcatheter valve-in-root implantation
CT scans of patients after biological root replacement and root repair were assessed with the 3mensio Software (Aortic valve package, 3mensio 10.1, Pie Medical Imaging. Before carrying out the measurements, markers for alignment of the aortic root and ascending aorta were placed manually. The annular area was measured for both groups. In patients after biological root replacement the area of the annulus was defined as the ring of the initial aortic valve prosthesis. Coronary buttons were measured at their lowest and highest point to define partial or full position below the valve level and the general button size. For assessment of the annular-to-coronary distance, the lower edge of the coronary button was chosen. VTC was assessed after root replacement in patients who had at least one coronary partially under the level of the valve. For this measurement a virtually inserted valve was placed in the bioprosthetic frame.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* postoperative ECG-gated CT-angiography scan
Exclusion Criteria
* missing postoperative ECG-gated CT-angiography scan
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Alicja Zientara
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Alicja Zientara
Principal investigator
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University hospital Freiburg, Department of Cardiovascular Surgery
Freiburg im Breisgau, , Germany
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ViR 2024
Identifier Type: -
Identifier Source: org_study_id
More Related Trials