Wearable Evaluation of Ambulatory Readings for Blood Pressure

NCT ID: NCT06610448

Last Updated: 2025-08-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

100 participants

Study Classification

INTERVENTIONAL

Study Start Date

2025-06-06

Study Completion Date

2026-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this project is to compare the performance and validity of novel wearable technologies that measure blood pressure (BP) and physical activity with a Spacelabs Ambulatory Blood Pressure Monitoring (ABPM) device.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The investigators will recruit community-dwelling participants to wear novel cuffless BP monitoring devices for comparison with a Spacelabs ABPM device throughout a 24-hour period. The identification of accurate cuffless BP technologies would greatly improve access to ABPM and allow for BP measurements at times when the use of cuff-based devices are not feasible. Knowledge from this project will inform subsequent research protocols among adults and under-represented groups.

Up to 250 participants (at least 100) will be involved in this study each wearing up to 7 devices (6 BP devices and 1 activity monitor). The assignment of devices will be randomized by day and by the arm or wrist on which they are worn. During the first visit, participants will provide their consent and be randomly fitted with 3 BP devices; either the Spacelabs ABPM device or the ABPMpro device, the Aktiia wristband BP monitor, and one of two other cuff-based wrist BP monitors, along with an activity monitor to track body positions. These devices will be worn continuously for at least 24-hours, including overnight, before being returned. On the following day, for Visit 2, participants will be fitted with a different set of 3 BP devices; the ABPMpro device or Spacelabs ABPM device, the Aktiia wristband BP device (on the opposite wrist from the previous day), and the final cuff-based wristband BP device. Additionally, participants will wear an ambulatory BP device as a patch on the chest. These devices will also be worn for at least 24 hours. This study will enable characterization of the feasibility, practicality, and effectiveness of the measurements and the devices\' accuracy and precision.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Normal Blood Pressure Controlled Hypertension Uncontrolled Hypertension

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Each participant is randomly assigned a different blood pressure device each day over the course of 3 days. All participants will use each device, but the devices will be applied on different days and on different arms.
Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Cuff-based ambulatory blood pressure monitor sequence

Participants will be randomized 1:1 to wear (A) the Spacelabs ambulatory blood pressure monitor on the first day and ABPMPro ambulatory blood pressure monitor on the second day or (B) ABPMPro ambulatory blood pressure monitor on the first day then Spacelabs ambulatory blood pressure monitor on the second day.

Group Type EXPERIMENTAL

ABPMPro

Intervention Type DEVICE

This is an upper arm, cuff-based intermittent ambulatory BP device. This device has an internal activity and body position sensor which gathers information about sleep-wake estimation.

Spacelabs Ambulatory Blood Pressure Monitoring

Intervention Type DEVICE

This is an upper arm cuff-based device with tubing for continuous ambulatory BP monitoring with a unique activity sensor that correlate with patient movement activity with blood pressure changes.

Left versus right upper limb

Participants will be randomized to wear the Aktiia cuffless blood pressure device on either the left upper limb versus the right upper limb on the first day. On the second day, the Aktiia blood pressure device will be switched to the other arm which did not get randomized on the first day. Another wristband (LiveMetric versus Bpro) will be worn on the contralateral arm.

Group Type EXPERIMENTAL

Aktiia Blood Pressure

Intervention Type DEVICE

This is a wrist cuff-based device which uses an optical sensor (photoplethysmography sensor) to gather data from the arteries under the skin surface. Aktiia has an upper arm cuff device which is used for calibration once every month to provide a baseline blood pressure reading.

LiveMetric

Intervention Type DEVICE

This is a wrist cuff-based applanation tonometry continuous ambulatory BP device. This device has automatic self-calibration and comes in various sizes.

Bpro

Intervention Type DEVICE

This is a wrist cuff-based wireless oscillometric, continuous ambulatory BP device. It has applanation tonometry at the wrist with Pulse wave analysis. This device needs calibration with a brachial cuff BP measurement.

Wristband sequence (first day versus second day)

Participants will be randomized 1:1 to wear (A) the LiveMetric wristband on the first day and Bpro wristband on the second day or (B) Bpro wristband on the first day then LiveMetric wristband on the second day. The arm side (i.e., right or left) will be determined by the Aktiia cuffless blood pressure device randomization on the first day. For the second day, the Aktiia cuffless blood pressure device will be worn on the arm opposite the first day with the other device (LiveMetric versus Bpro) worn on the contralateral arm.

Group Type EXPERIMENTAL

Aktiia Blood Pressure

Intervention Type DEVICE

This is a wrist cuff-based device which uses an optical sensor (photoplethysmography sensor) to gather data from the arteries under the skin surface. Aktiia has an upper arm cuff device which is used for calibration once every month to provide a baseline blood pressure reading.

LiveMetric

Intervention Type DEVICE

This is a wrist cuff-based applanation tonometry continuous ambulatory BP device. This device has automatic self-calibration and comes in various sizes.

Bpro

Intervention Type DEVICE

This is a wrist cuff-based wireless oscillometric, continuous ambulatory BP device. It has applanation tonometry at the wrist with Pulse wave analysis. This device needs calibration with a brachial cuff BP measurement.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

ABPMPro

This is an upper arm, cuff-based intermittent ambulatory BP device. This device has an internal activity and body position sensor which gathers information about sleep-wake estimation.

Intervention Type DEVICE

Spacelabs Ambulatory Blood Pressure Monitoring

This is an upper arm cuff-based device with tubing for continuous ambulatory BP monitoring with a unique activity sensor that correlate with patient movement activity with blood pressure changes.

Intervention Type DEVICE

Aktiia Blood Pressure

This is a wrist cuff-based device which uses an optical sensor (photoplethysmography sensor) to gather data from the arteries under the skin surface. Aktiia has an upper arm cuff device which is used for calibration once every month to provide a baseline blood pressure reading.

Intervention Type DEVICE

LiveMetric

This is a wrist cuff-based applanation tonometry continuous ambulatory BP device. This device has automatic self-calibration and comes in various sizes.

Intervention Type DEVICE

Bpro

This is a wrist cuff-based wireless oscillometric, continuous ambulatory BP device. It has applanation tonometry at the wrist with Pulse wave analysis. This device needs calibration with a brachial cuff BP measurement.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age 18 to 100 years
* All neighborhoods in Boston area
* Be able to walk with two limbs and have two arms
* Willing and able to complete required measurement procedures
* Able to provide informed consent

Exclusion Criteria

* Failure to receive informed consent
* Arm circumference of more than 50cm
Minimum Eligible Age

18 Years

Maximum Eligible Age

100 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Institutes of Health (NIH)

NIH

Sponsor Role collaborator

National Heart, Lung, and Blood Institute (NHLBI)

NIH

Sponsor Role collaborator

Stephen Juraschek

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Stephen Juraschek

Principal Investigator

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Beth Israel Deaconess Medical Center

Boston, Massachusetts, United States

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Stephen P. Juraschek, MD, PhD

Role: CONTACT

617-754-1416

Fredrick Larbi Kwapong, MD, MPH

Role: CONTACT

781-975-4920

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Stephen Juraschek, MD, PhD

Role: primary

6177541416

Related Links

Access external resources that provide additional context or updates about the study.

http://wearbp.org

Study website for potential participants

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

5R01HL158622

Identifier Type: NIH

Identifier Source: secondary_id

View Link

2024P000441

Identifier Type: -

Identifier Source: org_study_id

More Related Trials