Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2021-08-27

Study Completion Date

2024-05-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Optical interferometric biometry is a non-invasive and highly precise method for measuring eye length and intraocular distances. The method already exists as commercial devices (e.g. IOLMaster, Carl Zeiss Meditec AG). A major cost factor of the devices available on the market is the laser used. The use of a much cheaper laser could significantly reduce the price of these devices, which would lead to greater availability of this technology in developing countries. This would make it possible to replace the ultrasound methods used to date and thus enable contact-free measurements, which in turn can reduce the spread of infectious diseases.The study investigates the use of a thermally tunable vertical cavity surface emitting laser (VCSEL) for optical swept source biometry.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

1. Background

With 15 million operations per year, cataract surgery is the most commonly performed eye surgery. The number of operations worldwide is expected to increase by 25% between 2008 and 2015.

The simplest operation is the implantation of a monofocal intraocular lens (IOL). It is the most commonly performed cataract procedure in developing countries (e.g. 65% in India), as well as in rural and poor areas in industrialized countries. To prepare for the operation, simple IOL calculation formulas are used that require knowledge of the axial eye length. Today, biometry is mainly performed by applanation ultrasound and simple keratometers. However, optical measurement by low coherence interferometry (OCT) is becoming increasingly important, as it has the important advantage of being contact-free and thus avoiding complications that can be caused by possible infections. In addition, the method is extremely precise and does not depend on the skill of the doctor. A major cost factor in the production of such devices is the laser used. The use of a much cheaper laser diode could significantly reduce the price, which would ensure availability even in developing countries.
2. Rationale The suitability of electrically tuned VCSEL laser diodes as light sources for determining intraocular distances is to be investigated. The results are to be compared with those of a commercial device in terms of signal quality and measurement accuracy. Such a device would be contact-free, which would help prevent infections, would be significantly cheaper than currently available methods, and would be able to determine intraocular distances very precisely.
3. Study objectives The aim of the study is to demonstrate the usability of an electrically tuned VCSEL laser diode as a cost-effective alternative to the lasers used to date. To this end, the precision, reproducibility and manageability of the measurement with the VCSEL laser diode will be investigated. Test subjects and cataract patients will be examined. The precision of the measurement with the device of intraocular distances will be compared with that of a commercial device, IOLMaster500 from Carl Zeiss Meditec.
4. Study Design

The study is a pilot study. It takes the measurement principle of a commercially available device for measuring eye length as a starting point.

The technology used is swept source Optical Coherence Tomography. This swept source is to be implemented using the electrically tuned VCSEL laser diode. Such laser diodes are able to change their central wavelength by changing the driver current. Another advantage arises from the VCSEL technology used in the laser diode used. This type of laser diode has a very narrow instantaneous line width and thus a very long coherence length, which far exceeds that required for the biometry of the eye.

In swept source OCT, the attenuation of the signal in depth is much lower than in spectrometer-based systems. In addition, the sensitivity is higher than with time-domain partial coherence interferometry (PCI) biometry systems and they are much faster. The reason is that the entire axial structure is encoded in parallel in the spectrum.

4.1. Implementation and evaluation: In the proposed study, intraocular distances, primarily the axial eye length and the anterior chamber depth, of the participating subjects and patients are to be determined using the method described. This is an exploratory pilot study to determine whether the VCSEL-based technology is suitable (in terms of speed of measurement and sensitivity of the method) to achieve a precise determination of the axial eye length in both healthy subjects and cataract patients with various degrees of cataract. The measurements with the IOLMaster serve as a basis for comparison.

Participants in the study are to be healthy subjects and cataract patients. All participants will first undergo a routine examination. Other risks will also be identified during the routine examination. These examinations will be carried out at the Eye Clinic.

The test subjects and patients are then measured using the measurement setup at the Center for Medical Physics and Biomedical Engineering.

The routine examination at the eye clinic includes a slit lamp and eye length measurement. The eye to be examined is selected by the investigator during the routine examination.

4.2 Selection of the study population The participants are recruited via public notices. 30 healthy subjects are selected between the ages of 19 and 85 years. 30 cataract patients are selected between the ages of 19 and 85 years .

4.3 Preliminary examination:

* Routine examination at the Eye Clinic of the Medical University of Vienna. - - Measurement of eye length using IOL Masters.
* For cataract patients, the degree of cataract is determined based on the Lens Opacities Classification Systems (LOCS III)

4.4. Withdrawal or replacement of study participants

The study participants will be excluded from the study under the following circumstances:

* If they so wish
* If the study director believes that the study is not in the interest of the study participant
* If the study participant violates one of the requirements and points of the consent form In any case, the study exclusion will be recorded with a detailed explanation. If the study has to be terminated, the data will be retained.

Study participants who cannot complete the study will be replaced. The data can, however, be used for analysis.

4.5. Target variables

Axial eye length and anterior chamber depth: standard deviation and mean over repeated measurements will be analyzed; A comparison with the reference device will be established through Bland-Altman analysis.

Measurements are taken per study participant with IOL Master (Carl Zeiss Meditec AG) and measurement setup with current tuned VCSEL diode

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Cataract Myopia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

BASIC_SCIENCE

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Pilot Study

Pilot study in healthy participants and cataract patients

Group Type EXPERIMENTAL

Biometry

Intervention Type DEVICE

Only one eye from each patient will be included in the study. All subjects and patients included in the study will undergo biometric measurements with both devices (IOL master 500 and VCSEL based swept source optical biometry).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Biometry

Only one eye from each patient will be included in the study. All subjects and patients included in the study will undergo biometric measurements with both devices (IOL master 500 and VCSEL based swept source optical biometry).

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* healthy participants
* cataract patients (LOCS III grading)
* written informed consent

Exclusion Criteria

* corneal pathology that would significantly influence biometric measurements
* pathologies that could affect fixation abilities other than cataract
* pregnancy (for women in reproductive age a pregnancy test will be performed)
Minimum Eligible Age

19 Years

Maximum Eligible Age

95 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Mein Hanusch-Krankenhaus

OTHER

Sponsor Role collaborator

Rainer Leitgeb

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Rainer Leitgeb

Prof. Dr. Rainer Leitgeb

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Rainer Leitgeb, PhD

Role: PRINCIPAL_INVESTIGATOR

Medical University of Vienna

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Medical University of Vienna

Vienna, , Austria

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Austria

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

MUW_VBOB

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

MTF Image Modifications
NCT01926704 COMPLETED