Reliability and Validity of Hand Dynamometer Trunk Muscle Strength Measurements in Patients With AIS

NCT ID: NCT06416592

Last Updated: 2024-05-16

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Total Enrollment

41 participants

Study Classification

OBSERVATIONAL

Study Start Date

2024-06-01

Study Completion Date

2024-12-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Adolescent idiopathic scoliosis (AIS) is a three-dimensional complex deformity of the spine characterized by lateral deviation of 10 degrees or more in the frontal plane, rotation in the transverse plane and hypokyphosis in the sagittal plane. It has been reported that in the presence of scoliosis, there is a change in muscle strength of people compared to their healthy peers due to the deterioration of their postural balance. There are many studies in the literature that evaluate the muscle strength of cases diagnosed with scoliosis with objective devices. Among these objective devices, reliability studies on hand dynamometry devices, which are easy to use, portable and cheaper than other devices, have been conducted for different populations. However, no reliability study of the handheld dynamometer device in patients with AIS has been found in the literature. Therefore, the aim of our study is to study the intra-rater and inter-rater reliability and validity of the trunk flexion, extension and lateral flexion muscle strengths of the hand dynamometer device in cases with AIS, which are known to have changes in muscle strength compared to their peers as a result of the change in spinal alignment. After obtaining the demographic information of the cases that meet the inclusion criteria within the scope of the study, the isometric muscle strength of the trunk flexor, extensor and right-left lateral flexor muscles will be evaluated by two different evaluators using a Lafayette hand dynamometer. To avoid systematic error, each participant will perform the isometric handheld dynamometer protocol in a random testing order. In order to determine interobserver reliability, on the first day of the test, the same hand dynamometer protocol will be applied to each participant by two different evaluators, after a 1-hour rest to prevent fatigue. To determine intraobserver reliability and compliance, participants will be re-evaluated by the same researchers at the same protocol, place and day period, 1 week apart to prevent learning effects. This study will reveal the intraobserver and interobserver reliability and validity of the handheld dynamometer device, which can be used in the evaluation of trunk muscle strength for clinicians working with AIS.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Adolescent Idiopathic Scoliosis (AIS) is a three-dimensional complex deformity of the spine characterized by lateral deviation of 10 degrees or more in the frontal plane, rotation in the transverse plane and hypokyphosis in the sagittal plane, and is an important public health problem with a global prevalence of 0.47-5.2%. Muscle strength is an important factor in maintaining postural balance in AIS, and it is observed that both clinicians and researchers evaluate the muscle strength of cases with AIS using different objective devices. Objective muscle strength assessment methods include electromyography, hand dynamometry and isokinetic dynamometry. Electromyography devices and isokinetic dynamometers are expensive and their use in the clinic is limited because they are not easily portable. Therefore, it has been shown to be a valid and reliable method to evaluate trunk muscle strength in different populations and pathologies such as healthy adults, healthy athletic individuals, chronic low back pain or hemiplegic patients; The handheld dynamometer device, which has the advantage of being cheaper and more portable than other devices, appears as a suitable option for clinicians to evaluate trunk isometric muscle strength. No reliability studies of hand dynamometer devices have been found in the AIS population. Therefore, our aim in the study is to study the intra-observer and inter-observer reliability and validity of the trunk flexion, extension and lateral flexion muscle strengths of the hand dynamometer device in patients with AIS, who are known to have changes in muscle strength compared to their peers as a result of the change in spinal alignment. This study will reveal the validity of the hand dynamometer device that can be used in the evaluation of trunk muscle strength for clinicians working with AIS.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Scoliosis; Adolescence Adolescent Idiopathic Scoliosis

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Intra-rater and inter-rater validity and reliability

Intra-rater and inter-rater validity and reliability of trunk flexion, extension and right-left lateral flexion isometric muscle strength in cases with AIS will be performed with the Lafeyette hand dynamometer device ((Lafayette Manual Muscle Testing System, Lafayette Instrument Co, Lafayette, Indiana). To avoid systematic error, each participant will perform the isometric handheld dynamometer protocol in a random testing order. In order to determine inter-rater reliability, the same hand dynamometer protocol will be applied to each participant by two different assessors on the first day of the test. Participants will be given a 1-hour rest period between evaluators to prevent fatigue in the evaluations to be held on the same day. To determine inter-rater reliability and agreement, participants will be re-evaluated by the same researchers, at the same protocol, place and day, with a 1-week interval to prevent learning effects.

No interventions assigned to this group

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Being between the ages of 10-18
* Having been diagnosed with Adolescent Idiopathic Scoliosis by an orthopedic specialist
* Ability to understand instructions
* Volunteering to participate in the study

Exclusion Criteria

* History of traumatic trunk or pelvic injury
* History of acute, subacute or chronic low back pain or neurological disease
* Having had spinal surgery
* Participating in heavy physical activity at least one day before the test days
* Having experienced any acute situation that could affect muscle strength between the two tests (within 7 days)
Minimum Eligible Age

10 Years

Maximum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Istanbul University - Cerrahpasa

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Irem Kurt

Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

İrem Kurt Ulusoy

Role: PRINCIPAL_INVESTIGATOR

Istanbul University - Cerrahpasa

Elcin Akyurek

Role: PRINCIPAL_INVESTIGATOR

Istanbul University - Cerrahpasa

İpek Yeldan

Role: PRINCIPAL_INVESTIGATOR

Istanbul University - Cerrahpasa

Ayse Zengin Alpozgen

Role: PRINCIPAL_INVESTIGATOR

Istanbul University - Cerrahpasa

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

İrem Kurt

Istanbul, , Turkey (Türkiye)

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Turkey (Türkiye)

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

İrem Kurt Ulusoy

Role: CONTACT

+905326904872

Elcin Akyurek

Role: CONTACT

+905077403731

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IUC5

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.