High-Power, Short-Duration Ablation in Treatment of Patients With Atrial Fibrillation

NCT ID: NCT06415149

Last Updated: 2024-05-30

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

185 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-02-01

Study Completion Date

2024-03-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Atrial fibrillation (AF) stands as the most common type of cardiac arrhythmia. The frequency of AF in the overall population is 1-2%, with the incidence rate increasing with age from 0.5% in the 40-50 years old to 5-15% in those aged 80. \[According to current recommendations for catheter ablation (CA) in patients with AF, the isolation of the pulmonary veins (PV) is a pivotal aspect of treating this arrhythmia. Despite recent advancements, 20-45% of patients experience recurrences after PV isolation. According to the study by Wasmer K. et al., it was demonstrated that most patients with recurrent AF after PVI showed at least one reconnected vein during redo procedures. The primary cause of recurrences is the restoration of conduction, attributed to endurable isolation (non-transmural, intermittent RF). Numerous approaches have been presented to enhance the outcomes of surgical treatment for AF, such as the CLOSE protocol and Ablation Index (AI) . CLOSE protocol represents an approach aimed at isolating the PV ostia through precise continuous (distance between points ≤ 6 mm) radiofrequency intervention, achieving target ablation index values of ≥ 400au for the posterior wall and ≥ 500au for the anterior wall. The Ablation Index is a marker of quality lesion formation, providing a visual representation of the lesion based on the integration of power, contact force, and time parameters, which is displayed on the CARTO® 3 system (Biosense Webster).

Throughout radiofrequency ablation, electromagnetic energy undergoes conversion into thermal energy, leading to tissue damage and temperature elevation. The temperature elevation process encompasses two stages: resistive heating, impacting surface tissues (1-2mm), and conductive heating, which facilitates the transfer of heat from surface tissues to underlying tissues.

In the presence of good catheter-endocardium contact (25%), only 9% of the power is effectively delivered to the endocardium. For instance, at a power level of 30 watts and optimal contact (25%) with the endocardium, merely 2.7 watts are transferred to the endocardial tissue. When applying 30 watts of power for 30 seconds, a total energy delivery of 900 joules occurs, with only 90 joules being imparted to the endocardium. Similarly, at 50 watts for 10 seconds, only 45 joules of energy are transmitted to the endocardium. When operating at 10 watts, the catheter temperature elevates by 13°C. Consequently, at 30 watts, the temperature reaches 39°C, and at 50 watts, it rises to 65°C. The formation of an irreversible lesion necessitates a temperature exceeding 50°C. During standard radiofrequency ablation (RFA) procedures with power settings ranging from 20 to 45 watts and a duration of 20 to 60 seconds, the formation of ablation points predominantly occurs during the conductive heating phase.

High power short duration ablation (HPSD) is an approach that reduces the conductive heating phase while increasing the resistive heating phase. This results in an expanded area of lesion, facilitating the formation of transmural lesions in the atrial myocardium with irreversible tissue damage and reduced risk to surrounding structures, such as thermal injury to the esophagus.

The strategy of HPSD ablation was developed to overcome limitations of the traditional approach. However, much remains unknown regarding the safety and effectiveness of this approach. Additionally, the question for the optimal interventional treatment method for atrial fibrillation (AF) and the selection of the optimal RF energy for pulmonary vein isolation still require confirmation. This forms the basis for our research objective.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The research was a multi-center retrospective blind randomized controlled trial between 2021 and 2023. A comprehensive sample of 185 participants was enrolled in the study and categorized into 2 cohorts, each of which was further subdivided into two subgroups. Patients were enrolled in the study after providing informed consent. In the first group (n=95), PVI was performed with power of 50 watts in Ia subgroup (n=55) AI was 400-450 arbitrary units (au) for the posterior wall and 500-550 au for the anterior wall, in Ib (n=40) AI was 400-450 au for the posterior wall and 450-500 au for the anterior wall. In the second group (n=90), PVI was performed at a power of 45 watts, in IIa (n=50) with target AI of 400-450 au for the posterior wall and 500-550 au for the anterior wall in IIb (n=40) AI of 400-450 au for the posterior wall and 450-500 au for the anterior wall.

Assessment of conduction block was performed 20 minutes after RFA using a twenty-pole diagnostic electrode (Lasso, Biosense Webster, USA).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atrial Fibrillation Paroxysmal Atrial Fibrillation Persistent Atrial Fibrillation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

QUADRUPLE

Participants Caregivers Investigators Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

High power short duration ablation with 50 W

Group 1 (n=95): pulmonary vein isolation for treatment of atrial fibrillation was performed with power of 50 watts in Ia subgroup (n=55) AI (ablation index) was 400-450 arbitrary units (au) for the posterior wall and 500-550 au for the anterior wall, in Ib (n=40) AI was 400-450 au for the posterior wall and 450-500 au for the anterior wall.

Group Type EXPERIMENTAL

High power short duration ablation with 50 W

Intervention Type PROCEDURE

Group 1 (n=95): pulmonary vein isolation for treatment of atrial fibrillation was performed with power of 50 watts in Ia subgroup (n=55) AI (ablation index) was 400-450 arbitrary units (au) for the posterior wall and 500-550 au for the anterior wall, in Ib (n=40) AI was 400-450 au for the posterior wall and 450-500 au for the anterior wall.

High power short duration ablation with 45 W

Group 2 (n=90): Pulmonary vein islolation was performed at a power of 45 watts, in IIa subgroup (n=50) with target AI of 400-450 au for the posterior wall and 500-550 au for the anterior wall in IIb (n=40) AI of 400-450 au for the posterior wall and 450-500 au for the anterior wall.

Group Type EXPERIMENTAL

High power short duration ablation with 45 W

Intervention Type PROCEDURE

Group 2 (n=90): Pulmonary vein islolation was performed at a power of 45 watts, in IIa subgroup (n=50) with target AI of 400-450 au for the posterior wall and 500-550 au for the anterior wall in IIb (n=40) AI of 400-450 au for the posterior wall and 450-500 au for the anterior wall.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

High power short duration ablation with 50 W

Group 1 (n=95): pulmonary vein isolation for treatment of atrial fibrillation was performed with power of 50 watts in Ia subgroup (n=55) AI (ablation index) was 400-450 arbitrary units (au) for the posterior wall and 500-550 au for the anterior wall, in Ib (n=40) AI was 400-450 au for the posterior wall and 450-500 au for the anterior wall.

Intervention Type PROCEDURE

High power short duration ablation with 45 W

Group 2 (n=90): Pulmonary vein islolation was performed at a power of 45 watts, in IIa subgroup (n=50) with target AI of 400-450 au for the posterior wall and 500-550 au for the anterior wall in IIb (n=40) AI of 400-450 au for the posterior wall and 450-500 au for the anterior wall.

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Symptomatic atrial fibrillation (AF) or resistance to at least one antiarrhythmic drug from the first or third group of antiarrhythmic drugs.

Exclusion Criteria

1. Left atrial thrombosis
2. significant coronary artery disease requiring revascularization
3. valvular heart disease requiring surgical correction
4. acute infectious diseases
5. severe heart failure (NYHA class IV) or left ventricular ejection fraction (LVEF) \<35%,
6. history of stroke within the past 3 months.
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

City Clinical Hospital No.1 named after N.I. Pirogov

OTHER

Sponsor Role collaborator

People's Friendship University of Russia

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

afsoon fayez

Dr.

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

People's friendship university of Russia

Moscow, , Russia

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Russia

References

Explore related publications, articles, or registry entries linked to this study.

Fayez A. , Safonov N. V., Steklov A. S., Faybushevich A. G., Baranovich V. Y. HIGH POWER SHORT DURATION ABLATION USING ABLATION INDEX (AI) IN PATIENTS WITH ATRIAL FIBRILATION // Современная наука: актуальные проблемы теории и практики. Серия: Естественные и Технические Науки. -2023. -№02. -С. 244-250 DOI 10.37882/2223-2966.2023.02.37

Reference Type BACKGROUND

Related Links

Access external resources that provide additional context or updates about the study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

27711

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.