Magnetic Bead Tracking System and eOPRA Implant System With Bionic Prosthesis for Transtibial Amputees
NCT ID: NCT06391697
Last Updated: 2025-10-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
7 participants
INTERVENTIONAL
2024-05-01
2027-05-02
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
A maximum of seven subjects will be enrolled. Each subject will undergo one or more surgeries where the e-OPRA Implant System and Magnetic Bead Tracking System will be implanted. The subjects will participate in follow-up sessions the last of which occurs approximately 24 months after the surgery. This is a prospective, non-randomized, uncontrolled study.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Osseointegrated Transtibial Prosthesis With Neural Interface
NCT05249049
Neuromusculoskeletal Interface for Bionic Arms
NCT07032753
A Multicenter, Multinational, Cohort Long-term Post-market Clinical Follow-up (PMCF) of the Safety and Efficacy of the Osseoanchored Prostheses for the Rehabilitation of Amputees (OPRA) Implant System When Used for Transhumeral Implantation in Amputee Patients
NCT06753110
Active Knee Prosthesis Study
NCT06700668
Agonist-Antagonist Myoneural Interface for Functional Limb Restoration After Transtibial Amputation
NCT03913273
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Investigators have sought to advance bionic prostheses with sufficient degrees of freedom for performing natural tasks, such as manipulating objects in the case of upper-extremity prostheses, or walking and running for lower-extremity systems. Nonetheless, afferent feedback has not played a major role in any clinically-viable amputation prostheses, despite being critical for biomimetic control. This deficiency can, in large part, be attributed to a lack of clinically-available methodologies for sustained communication with the peripheral nervous system. There is no existing platform capable of invasive, robust, and permanent communication with the peripheral nervous system in a high-demand clinical set- ting. Only by bringing together critical technologies and expertise will it be possible to create a bionic limb replacement system with adequate suspension, load transmission, motor control, proprioceptive feedback, and external mechatronics that resemble the mass, volume and dynamics of the missing biological limb.
To develop the most advanced clinically- viable artificial limb and achieve the next level of prosthetic technology integration, a multi-disciplinary scientific team has been assembled with members from Massachusetts Institute of Technology (MIT: Carty, Herr, Brånemark) and Brigham and Women's Hospital (BWH: Carty, Ferrone). With proprioceptive afferent feedback, we seek to demonstrate that a person with transtibial amputation can exhibit full volitional control over a neuro-mechanical prosthetic system where key walking metrics are normalized, including preferred speed, metabolism and joint dynamics. It is the view of the proposers that the scope of this research is fundamental wherein the results will be shared broadly within the scientific community.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DEVICE_FEASIBILITY
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
eOPRA Implant System for Transtibial Amputees and Magnetic Bead Tracking System
Implantation of e-OPRA Implant System and Magnetic Bead Tracking System in lower limb.
eOPRA Implant System for Transtibial Amputees and Magnetic Bead Tracking System
The Magnetic Bead Tracking System is an investigational device that consists of pairs of magnetic beads, and a set of magnetic field sensors that measure and track the length of muscles and the speed at which they move in real-time. When the beads are implanted in muscle in the residual limb of an amputee, the muscle length signal is communicated to an investigational, robotic ankle-foot prosthesis.
The e-OPRA is an investigational implant system that lets a lower leg prosthesis attach securely to the remaining tibia bone. The e-OPRA device has been designed so that it can be implanted with an electrode set that consists of an electrical connector and electrodes to allow it to be used with both a neuro-mechanical (powered) prosthesis system, in addition to the standard prosthesis.
The operation to implant these devices will represent a modification of the surgical technique currently employed for standard below knee amputation.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
eOPRA Implant System for Transtibial Amputees and Magnetic Bead Tracking System
The Magnetic Bead Tracking System is an investigational device that consists of pairs of magnetic beads, and a set of magnetic field sensors that measure and track the length of muscles and the speed at which they move in real-time. When the beads are implanted in muscle in the residual limb of an amputee, the muscle length signal is communicated to an investigational, robotic ankle-foot prosthesis.
The e-OPRA is an investigational implant system that lets a lower leg prosthesis attach securely to the remaining tibia bone. The e-OPRA device has been designed so that it can be implanted with an electrode set that consists of an electrical connector and electrodes to allow it to be used with both a neuro-mechanical (powered) prosthesis system, in addition to the standard prosthesis.
The operation to implant these devices will represent a modification of the surgical technique currently employed for standard below knee amputation.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. The subject must already have been implanted with the e-OPRA Implant System at the transtibial level or must have an existing unilateral or bilateral transtibial amputation or a medical condition requiring performance of a unilateral or bilateral transtibial amputation with a minimum of 8 cm of residual tibia after amputation, such that the subject will be implanted with the e-OPRA Implant System. (OPTION 1)
3. If the subject does not already have the e-OPRA Implant System, the subject must have undergone independent consultation with at least two lower extremity surgical specialists to ensure they have exhausted all limb salvage options prior to undergoing amputation, as well as a psychiatric evaluation to ensure appropriate capacity and volition. (OPTION 2)
4. The patient must have the ability to ambulate at variable cadence (an expected lower extremity prosthesis functional level of K3 or above, as confirmed by study investigators).
5. The patient must have adequate soft tissue bulk and muscle mass present in the operative limb to support appropriate wound healing.
6. In the opinion of the investigator, normal cognitive function and absence of any physical limitations, addictive diseases or underlying medical conditions that may preclude the patient from being a good study candidate.
7. Willingness, ability and commitment to participate in baseline and follow-up evaluations for the full length of the study.
8. Willingness and ability to provide informed consent to participate in the study.
Exclusion Criteria
2. Subjects with severe co morbidity, atypical skeletal anatomy, or poor general physical/mental health that, in the opinion of the Investigator, will not allow the subject to be a good study candidate (i.e. other disease processes, mental capacity, substance abuse, shortened life. expectancy, vulnerable patient population, BMI \>40, etc.).
3. For subjects who have not yet been implanted with the e-OPRA Implant System, subjects who would have less than 2 mm of remaining cortex bone available around the implant, if implanted.
4. Subjects with advanced atrophic muscle and/or compromised soft tissue coverage in the operative limb.
5. Subjects with evidence of or a documented history of severe peripheral vascular disease, diabetes mellitus (type I or type II), skin diseases, neuropathy or neuropathic disease and severe phantom pain, or osteoporosis, such that, in the opinion of the investigator, will not allow the subject to be a good study candidate.
6. Subjects with a history of systemically administered corticosteroids, immune-suppressive therapy or chemotherapy drugs within six (6) months of implant surgery.
7. Subjects with a known need of future MRIs.
8. Subjects currently involved in another clinical study where that participation may conflict or interfere with the treatment, follow-up or results of this clinical study.
9. Active smokers will be excluded from candidacy; those patients willing to undergo tobacco cessation will need to be completely abstinent from tobacco use for at least 6 weeks preoperatively.
10. Women who are pregnant, lactating or planning a pregnancy during the first twelve (12) months of the post-surgical follow-up.
11. Subject has an allergy to any component of the device.
12. Concurrent illness, disability or geographical residence would hamper attendance at required study visits.
22 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Massachusetts Institute of Technology (MIT)
UNKNOWN
Integrum
INDUSTRY
Brigham and Women's Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Matthew Carty
Roberta and Stephen R. Weiner Distinguished Chair in Surgery, Staff Surgeon BWH
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Matthew J Carty, MD
Role: PRINCIPAL_INVESTIGATOR
Brigham and Women's Hospital
Hugh Herr, PhD
Role: PRINCIPAL_INVESTIGATOR
Massachusetts Institute of Technology
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Brigham and Women's Hospital
Boston, Massachusetts, United States
MIT Media Lab
Cambridge, Massachusetts, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2024P00006
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.