All-Polyethylene Tibias in TKA: PS vs CS Implants

NCT ID: NCT03569670

Last Updated: 2021-09-14

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

WITHDRAWN

Clinical Phase

NA

Study Classification

INTERVENTIONAL

Study Start Date

2020-01-31

Study Completion Date

2022-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This is a randomized control trial where patients will be randomized to receive one of two types of total knee arthroplasty (TKA) all-polyethylene (AP) tibial components: cruciate retaining (CR) or posterior stabilized (PS). We will use radiostereometric analysis to assess the stability of the implants at 6 weeks, 3 months, 6 months, 1 year and 2 year post-operatively. The main objective of this project will be to determine which AP tibial component offers the greatest stability. Additionally, we will seek to determine whether patient BMI significantly impacts the stability of AP tibial components.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

With healthcare expenditures rising as our population ages, there have been significant efforts targeted towards streamlining costs associated with various medical treatments. One area of substantial spending in the orthopaedic surgery field is total joint replacements. The effort to reduce costs has sparked a renewed interest in the use of allpolyethylene (AP) tibial components in total knee arthroplasty (TKA).

In recent years, there has been ample research demonstrating that AP tibial components have performed as good as, or better, than metal-backed (MB) tibial components. Some studies have estimated that cost savings could be as high as 50% with routine use of AP tibial components. While sufficient literature exists demonstrating the equivalence or superiority of AP versus MB designs, there is a paucity of work done comparing different types of AP tibial components.

Tibial components in TKA can be of the posterior stabilizing (PS) or cruciate retaining (CR) variety. To date, we are unaware of any study that directly compares AP tibial PS components to AP tibial CR components.

Radiostereometric analysis (RSA) has evolved as an exceptionally precise and reliable method for assessing the migration of components in total joint arthroplasty. Using RSA data, it is possible to accurately predict, within the first 24 months post-operatively, the survival of a total joint arthroplasty. Furthermore, the use of RSA outcomes in arthroplasty research allows for adequately powered studies with significantly smaller sample sizes than previously required.

The main objective of this project will be to determine which AP tibial component offers the greatest stability. Additionally, we will seek to determine whether patient body mass index (BMI) significantly impacts the stability of AP tibial components.

We will prospectively enroll patients who will be undergoing a total knee arthroplasty by one of the study investigators. Potentially eligible patients will have the project explained to them during their preadmission clinic visit prior to surgery and if interested a member of the research team will perform the informed consent process. Should a patient elect to participate in the study they will sign the informed consent form and complete demographics and baseline health related quality of life questionnaires including Oxford Knee, EQ-5D, and the VR-12, in addition to the Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) which is already completed as per standard of care. The baseline demographic characteristics that will be collected include age, BMI, gender, and relevant medical comorbidities. Patients will be randomized to have either a PS or CR all-poly tibial component used during surgery. Randomization will be stratified by BMI to ensure equal distribution in both groups.

During surgery the surgeon will insert 6-9 tantalum beads in the proximal tibial, 6 beads in the polyeythylene tray, and another bead into the tip of the polyethylene stem. These beads will be used to measure migration of the implants on RSA imaging (radiostereometric analysis).

The RSA x-rays will be taken at baseline (2 weeks) and at the 6-week, 3 months, 6 months and 1 year and 2 year follow-up appointments. These images will be taken at Robarts Research Institute in the RSA analysis suite. At the 3month, 6 month, 1 year and 2 year visits we will also collect health related quality of life questionnaires including the WOMAC, Oxford Knee, EQ-5D and the VR-12.

Patients and data collector will be blinded to treatment arm. The person who will analyze the RSA images will be able to see which treatment arm participants belong to (based on viewing xrays) however the hypothesis of the study will not be revealed to them prior to analysis.

Intra-operative cost information will also be collected using institutional cost data in order to compare differences in OR costs between the two implant designs and across BMI categories.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Osteoarthritis, Knee

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Posterior Stabilized

A posterior stabilized, all-polyethylene tibial component will be used during surgery.

Group Type EXPERIMENTAL

Posterior stabilized all-polyethylene tibial component

Intervention Type DEVICE

Patients randomized to this arm will have a Triathlon implant with a posterior stabilized, all-polyethylene tibial component used during surgery.

Cruciate Retaining

A cruciate retaining, all-polyethylene tibial component will be used during surgery.

Group Type ACTIVE_COMPARATOR

Cruciate retaining all-polyethylene tibial component

Intervention Type DEVICE

Patients randomized to this arm will have a Triathlon implant with a cruciate retaining, all-polyethylene tibial component used during surgery.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Posterior stabilized all-polyethylene tibial component

Patients randomized to this arm will have a Triathlon implant with a posterior stabilized, all-polyethylene tibial component used during surgery.

Intervention Type DEVICE

Cruciate retaining all-polyethylene tibial component

Patients randomized to this arm will have a Triathlon implant with a cruciate retaining, all-polyethylene tibial component used during surgery.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* osteoarthritis
* primary total knee arthroplasty
* able to consent for themself

Exclusion Criteria

* inflammatory arthropathy
* fibromyalgia
* chronic pain syndrome
* previous distal femur or proximal tibia open reduction internal fixation
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Western Ontario, Canada

OTHER

Sponsor Role collaborator

London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Edward Vasarhelyi, MD

Role: PRINCIPAL_INVESTIGATOR

London Health Sciences Centre

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

London Health Sciences Centre - University Hospital

London, Ontario, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

References

Explore related publications, articles, or registry entries linked to this study.

Gioe TJ, Maheshwari AV. The all-polyethylene tibial component in primary total knee arthroplasty. J Bone Joint Surg Am. 2010 Feb;92(2):478-87. doi: 10.2106/JBJS.I.00842.

Reference Type BACKGROUND
PMID: 20124081 (View on PubMed)

Medel F, Kurtz SM, Klein G, Levine H, Sharkey P, Austin M, Kraay M, Rimnac CM. Clinical, surface damage and oxidative performance of poly II tibial inserts after long-term implantation. J Long Term Eff Med Implants. 2008;18(2):151-65. doi: 10.1615/jlongtermeffmedimplants.v18.i2.40.

Reference Type BACKGROUND
PMID: 19968624 (View on PubMed)

Adalberth G, Nilsson KG, Bystrom S, Kolstad K, Milbrink J. Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty: prospective, randomized radiostereometric analysis study of the AGC total knee prosthesis. J Arthroplasty. 2000 Sep;15(6):783-92. doi: 10.1054/arth.2000.8101.

Reference Type BACKGROUND
PMID: 11021456 (View on PubMed)

Yassin M, Garti A, Weissbrot M, Ashkenazi U, Khatib M, Robinson D. All-polyethylene tibial components are not inferior to metal-backed tibial components in long-term follow-up of knee arthroplasties. Eur J Orthop Surg Traumatol. 2015 Aug;25(6):1087-91. doi: 10.1007/s00590-015-1645-y. Epub 2015 May 26.

Reference Type BACKGROUND
PMID: 26006786 (View on PubMed)

Norgren B, Dalen T, Nilsson KG. All-poly tibial component better than metal-backed: a randomized RSA study. Knee. 2004 Jun;11(3):189-96. doi: 10.1016/S0968-0160(03)00071-1.

Reference Type BACKGROUND
PMID: 15194094 (View on PubMed)

Nouta KA, Verra WC, Pijls BG, Schoones JW, Nelissen RG. All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression. Clin Orthop Relat Res. 2012 Dec;470(12):3549-59. doi: 10.1007/s11999-012-2582-2. Epub 2012 Sep 13.

Reference Type BACKGROUND
PMID: 22972656 (View on PubMed)

Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop. 2005 Aug;76(4):563-72. doi: 10.1080/17453670510041574.

Reference Type BACKGROUND
PMID: 16195075 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

110812

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Porous Baseplate in Total Knee Replacement
NCT05226689 ACTIVE_NOT_RECRUITING NA
All-poly Versus Metal-backed
NCT04358601 ACTIVE_NOT_RECRUITING NA
10003 PRO Current Products
NCT01497730 COMPLETED