Innovative Technologies for Salvage Procedures of Failed Treatments of Osteoarthritis: Biomimetics Solutions (CustomPN)
NCT ID: NCT06527664
Last Updated: 2025-01-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
15 participants
OBSERVATIONAL
2024-10-01
2026-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Preoperatively, the patient will undergo a clinical evaluation. Data will be collected on the patient's general health status with the Charlson score, the reason for revision, number of revisions, type of implant in place, and the time elapsed between the failed implant and the revision in question. The bone deficit will be studied through CT measurements according to qualitative and quantitative scales. During the surgery, information on intraoperative complications will be collected. In the postoperative period, perioperative complications will be collected according to the Clavien Dindo classification. The clinical radiographic evaluations will be carried out during outpatient follow-up visits at 1, 3, 12, 24, and 36 months after revision. They include the Harris Hip Score clinical score, the EQ-5D PROM, and the patient's satisfaction level (qualitative assessment in 4 grades: unsatisfied, slightly satisfied, moderately satisfied, fully satisfied). The positional parameters of the implant will be evaluated, as compared to the immediate post-operative X-ray: acetabular abduction, acetabular anteversion, center of rotation height, center of rotation medialization, and inclination of the custom-made component. From 12 months onwards, the osteointegration characteristics of the component will be assessed: presence of radial trabeculae at the interface, superolateral and inferior reinforcements, stress shielding, absence of radiolucent lines. Re-revision rates will be determined using the Kaplan-Meier method. The reasons for re-revision will be noted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Use of Leukocyte-Rich PRP or Leukocyte-Free PRP in the Treatment of Hip Osteoarthritis
NCT05497349
Identification of New Predictive Osseointegration Bio-Markers of the Prosthetic Implant in Patients With OsteoArthritis
NCT03726918
Clinical and Radiographic Outcomes of the JointMedica Custom-Made Resurfacing Device
NCT07094139
A Study to Evaluate the Conformis iTotal Identity Knee Replacement System
NCT04667559
Treatment of Osteoarthritis of the Hip Joint With Intra-articular Injection of Microfractured Autologous Adipose Tissue Containing Mesenchymal Stromal Cells.
NCT05465096
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The aims are:
Description of demographic characteristics and bone defect in candidates for acetabular reconstruction with custom-made implants Perioperative complications and implant survival Clinical evaluation of custom-made implants in custom-made acetabular reconstructions in hip prosthesis revisions with severe bone loss (clinical score Harris Hip Score; subjective score PROM EQ-5D; post-operative patient satisfaction level) Radiographic evaluation (positioning and osteointegration) of custom-made implants in custom-made acetabular reconstructions in hip prosthesis revisions with severe bone loss This is a prospective multicenter study. The study population will consist of adult individuals consecutively treated for revision hips, requiring a custom-made acetabular implant. Patients with a diagnosis leading to an oncological revision will not be included. The custom-made implant is a personalized implant created by an external company based on the pre-operative CT scan that details the bone damage. Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 (loss of the superolateral part and one of the two ventro-caudal walls). In these cases, off-the-shelf therapeutic options are limited and achieve uncertain outcomes: therefore, a custom-made component with ultra-porous anchoring surfaces can represent a highly advantageous therapeutic choice. After identifying the suitable patient and obtaining their consent for the study, a pre-operative CT scan will be performed as per normal clinical practice for every revision. After uploading it to the dedicated website or app of the company, this CT scan will be used for the manufacturing of the custom-made implant by a third-party company. The company will also provide plastic phantoms for preliminary study of the implant. Upon approval of the implant production, the company will manufacture the implant according to current regulations and production techniques, following previous and established clinical practice. The device will be accompanied by personalized instrumentation, such as cutting guides, positioners, calipers, and plastic simulation phantoms, to facilitate the surgical procedure. The implant and the produced instrumentation will be delivered to the reference center after performing the patient's surgical planning.
Preoperatively, the patient will undergo an evaluation with the Harris Hip score clinical score. Additionally, data will be collected on the patient's general health status with the Charlson score, the reason for revision, number of revisions, type of implant in place, and the time elapsed between the failed implant and the revision in question. The bone deficit will be studied through CT measurements according to qualitative and quantitative scales.
During the surgery, information on intraoperative complications will be collected. In the postoperative period, perioperative complications will be collected according to the Clavien Dindo classification. The clinical radiographic evaluations will be carried out during outpatient follow-up visits at 1, 3, 12, 24, and 36 months after revision. They include the Harris Hip Score clinical score, the EQ-5D PROM, and the patient's satisfaction level (qualitative assessment in 4 grades: unsatisfied, slightly satisfied, moderately satisfied, fully satisfied). The positional parameters of the implant will be evaluated, as compared to the immediate post-operative X-ray: acetabular abduction, acetabular anteversion, center of rotation height, center of rotation medialization, and inclination of the custom-made component. From 12 months onwards, the osteointegration characteristics of the component will be assessed: presence of radial trabeculae at the interface, superolateral and inferior reinforcements, stress shielding, absence of radiolucent lines. Re-revision rates will be determined using the Kaplan-Meier method. The reasons for re-revision will be noted.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Custom-made
Revision hip arthroplasty performed for non-oncological reasons, with Paprosky III bone loss
custom-made acetabular implant
custom-made acetabular implant produced with additive manufacturing, to fill the bony loss in Paprosky III bone defects
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
custom-made acetabular implant
custom-made acetabular implant produced with additive manufacturing, to fill the bony loss in Paprosky III bone defects
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* pre-operative CT scan
* adults patients (minimum age: 18 years)
* complete medical charts
* patients' availability
Exclusion Criteria
* other types of revision implant (non custom)
* inadequate medical chart
* lack of pre-operative CT scan
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Istituto Ortopedico Rizzoli
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Francesco Traina, Prof
Role: PRINCIPAL_INVESTIGATOR
IRCCS Istituto Ortopedico Rizzoli
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
Bologna, , Italy
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Romagnoli M, Zaffagnini M, Carillo E, Raggi F, Casali M, Leardini A, Marcheggiani Muccioli GM, Grassi A, Zaffagnini S. Custom-made implants for massive acetabular bone loss: accuracy with CT assessment. J Orthop Surg Res. 2023 Sep 30;18(1):742. doi: 10.1186/s13018-023-04230-5.
Pandey AK, Zuke WA, Surace P, Kamath AF. Management of acetabular bone loss in revision total hip replacement: a narrative literature review. Ann Jt. 2023 Oct 5;9:21. doi: 10.21037/aoj-23-23. eCollection 2024.
Jones SA, Parker J, Horner M. Can a reconstruction algorithm in major acetabular bone loss be successful in revision hip arthroplasty? Bone Joint J. 2024 May 1;106-B(5 Supple B):47-53. doi: 10.1302/0301-620X.106B5.BJJ-2023-0809.R1.
Kim K, Sandiford NA. The Role of Three-Dimensional Custom Printing in Revision Total Hip Arthroplasty. Surg Technol Int. 2023 Sep 15;42:369-373. doi: 10.52198/23.STI.42.OS1698.
Pardo F, Bordini B, Castagnini F, Giardina F, Faldini C, Traina F. Are powder-technology-built stems safe? A midterm follow-up registry study. J Mater Sci Mater Med. 2021 Jan 20;32(1):10. doi: 10.1007/s10856-020-06481-8.
Castagnini F, Mariotti F, Tassinari E, Bordini B, Zuccheri F, Traina F. lsolated acetabular revisions of articular surface replacement (ASR) XL implants with highly porous titanium cups and Delta bearings. Hip Int. 2021 Mar;31(2):250-257. doi: 10.1177/1120700019874442. Epub 2019 Sep 4.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
344/2024/Oss/IOR
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.