a Ultrasonographic Measurement of Intra-abdominal Pressure
NCT ID: NCT06390605
Last Updated: 2024-04-30
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
9 participants
OBSERVATIONAL
2024-05-01
2025-05-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Currently, there are various methods for measuring intra-abdominal pressure, including direct intraperitoneal measurement, transbladder measurement, gastric measurement, superior and inferior vena cava measurement, rectal measurement, and noninvasive measurement. However, the most commonly used clinical method is indirect transbladder measurement. This technique is clinically feasible and accurate, making it the internationally recognized "gold standard" for intra-abdominal pressure monitoring. Nevertheless, it has been reported that the accuracy and reproducibility of intra-bladder pressure measurements can be influenced by many factors, resulting in a large coefficient of variation in intra-abdominal pressure measurements obtained by this method. Additionally, the indirect transbladder measurement technique is cumbersome, discontinuous, and carries a potential risk of infection. Therefore, the development of noninvasive, safe, and reliable IAP monitoring techniques or methods has garnered widespread attention from scholars both domestically and internationally.
This study measures IAP using a combination of ultrasound and external pressure application. By comparing it with the gold standard, intra-bladder pressure measurement, we observe the accuracy and reliability of this measurement method. The aim is to provide a noninvasive, fast, accurate, and reliable method for measuring intra-abdominal pressure in critically ill patients.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Prevalence, Risk Factors, and Prognostic Factors of Intraabdominal Hypertension and Abdominal Compartment Syndrome in Critically Ill Surgical Patients in Ramathibodi Hospital
NCT03762057
Correlation Between Intestinal Blood Flow and Intestinal Dysfunction in Critically Ill Patients
NCT06049979
A Deep Learning Model for Blood Volume Estimation From Multi-modal Ultrasound
NCT06957587
Central Venous Pressure Monitoring and Prognosis of High-risk Operating Patients
NCT04596332
Ultrasound of the Inferior Vena Cava in the Prevention of Hypotension After Induction of General Anesthesia
NCT06530901
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Four pressure-sensing patches, each with a diameter of 0.5mm, are placed at the four corners of the linear array probe. The placement positions are based on not affecting ultrasonic imaging, and they are fixed around the probe through a bracket. The wires of the four pressure-sensing patches are connected to a pressure measurement module, which can process the pressure exerted on the four patches and calculate the average pressure. Finally, the pressure exerted on the four patches and the average pressure value are displayed on the monitor.
2. Measurement of IAP Using Ultrasound Combined with External Pressure Application
The operation was performed by two researchers who were unaware of each other's measurement results. The first researcher had more than 3 years of experience in critical ultrasound operation and was familiar with the ultrasound combined with external pressure application method and operation procedure before the study began, so no additional training was required. The second researcher also had more than 3 years of experience in critical ultrasound operation but was not aware of the ultrasound combined with external pressure application method. The first researcher trained the second researcher, only informing the latter of how to use ultrasound combined with external pressure to measure intra-abdominal pressure. Using a Philips ultrasound system (model: IU22) and a linear array probe (frequency: 5-12 mHz), preset superficial parameters and two-dimensional mode were selected. The researchers adjusted the depth and gain to clearly display the peritoneal line, with the focus centered on the peritoneal line and the grayscale compression set to automatic adjustment mode, generally between 60% and 70%.
During measurement, the patient lies on their back with the abdominal wall relaxed. The bladder is emptied through a urinary catheter. The measurement device for pressure applied by the ultrasonic probe is fixed to the probe and gently placed 2cm above the navel, perpendicular to the abdominal wall. Observe and record the original shape of the peritoneal line, then gradually apply pressure until the peritoneal line changes shape towards the peritoneal cavity and record the pressure value. Finally, quickly remove the pressure on the probe and observe whether the peritoneal line returns to its original shape. If the peritoneal line returns to its original shape, the recorded pressure value is the intra-abdominal pressure. Each researcher measures twice consecutively, and the average value is taken as the final value. Each patient is measured once within 24 hours of ICU admission and again after 72 hours.
3. Measurement of IAP by Intra-bladder Pressure Method
After the measurement using ultrasound combined with external pressure, a third researcher who is unaware of the ultrasound measurement results performs the intravesical pressure method. This is done according to the standards recommended by the World Abdominal Compartment Syndrome Federation. The specific method is as follows: insert a urinary catheter into the bladder, empty the urine from the bladder, and then inject 25ml of normal saline into the bladder through the catheter. Connect a T-junction and a pressure measuring tube. During the measurement, the patient lies on their back with the abdominal covering removed, using the axillary midline as the "zero" point. The height of the water column represents the intra-abdominal pressure. During the measurement process, the patient should maintain calm breathing, and the reading should be taken at the end of exhalation to minimize errors. If the patient is using a ventilator with positive end-expiratory pressure, the ventilator tubing should be disconnected for measurement to reduce the influence of ventilator-assisted ventilation on intra-abdominal pressure.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients suspected of having elevated intra-abdominal pressure.
* Patients who have agreed to participate in this study and signed a written informed consent form, either by themselves or through their immediate family members.
Exclusion Criteria
* Patients with pathological changes in the abdominal wall, such as congenital malformations, injuries, hematomas within the rectus sheath, infections, tumors, hernias, etc.
* Patients whose water column does not show respiratory phase changes during intra-bladder pressure measurement.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ruijin Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
weiqing zhang, Ph.D.
Role: PRINCIPAL_INVESTIGATOR
Ruijin Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
Shanghai, Shanghai Municipality, China
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ZWQ21886-2024-1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.