A Study to Evaluate the Performance, Usability, and Result Interpretation of INSTI® HIV Self-Test

NCT ID: NCT06368453

Last Updated: 2025-07-11

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

1728 participants

Study Classification

INTERVENTIONAL

Study Start Date

2024-05-02

Study Completion Date

2025-01-08

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The objective of this study is to evaluate the performance, usability, and result interpretation of the INSTI® HIV Self-Test (referred to INSTI® HIV ST) in the intended use population across the United States (US). The INSTI® HIV Self-Test is a single use in vitro test that is used as a self-test for the detection of antibodies to HIV-1 and HIV-2 in human fingerstick blood. This study is designed to evaluate INSTI® HIV ST performance in the hands of non-professionals and untrained lay users who are inexperienced in HIV blood-based self-testing.

The study aims to:

To evaluate the clinical performance (i.e., diagnostic sensitivity and specificity) of the INSTI® HIV Self-Test in a lay user population.

To assess the user's comprehension of the INSTI® HIV ST results (e.g., interpreting positive, negative, and invalid results).

To evaluate the usability of the INSTI® HIV ST and understand users' experience in performing the test.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The objective of this study is to evaluate the performance, usability, and result interpretation of the INSTI® HIV Self-Test (referred to INSTI® HIV ST) in the intended user population across the United States (US). This study is designed to evaluate INSTI® HIV ST performance in the hands of non-professionals and untrained lay users who are inexperienced in HIV self-testing.

The study aims to:

To evaluate the clinical performance (i.e., diagnostic sensitivity and specificity) of the INSTI® HIV ST in a lay user population.

To assess the user's comprehension of the INSTI® HIV ST results (e.g., interpreting positive, negative, and invalid results).

To evaluate the usability of the INSTI® HIV ST and understand users' experience in performing the test.

Subjects will be consecutively enrolled from the 'general' population (i.e., "all comers" group of previously undiagnosed HIV individuals) until a minimum of 27 HIV positive and 1000-1700 HIV negatives are obtained. Subjects will be lay users recruited at multiple sites across the US. This study is to determine if lay users, unassisted, can perform the INSTI® HIV ST correctly and without significant risk of incorrect results. The study will help to determine if the INSTI® HIV ST instructions are easy to understand for the US public. The overall study processes include a performance evaluation, where subjects will perform the INSTI® HIV ST, a mock results interpretation study to assess the user's comprehension of the INSTI® HIV ST results and usability evaluation to understand users experience with the INSTI® HIV ST. Only a subset of the enrolled subjects (500 subjects) will participate in the mock results interpretation study and usability evaluation.

For the performance evaluation, subjects will perform the INSTI® HIV ST without any intervention from an observer. Following the subjects self-testing, an operator will collect an additional fingerstick sample to perform a comparator test. The positive and negative percent agreement (i.e., PPA and NPA) between the INSTI® HIV ST result and comparator will be calculated. In the event of discrepant results between the INSTI® HIV ST and comparator test, an additional venous blood sample will be collected from the subject for discrepancy testing.

A subset of the enrolled subjects will then participate in the mock results interpretation study and usability evaluation. For the mock study, the subjects will be presented with 5 mock INSTI® HIV ST devices with different results, and the subject's interpretation of each device will be recorded. The percentage of subjects who interpreted the mock results correctly for each result type will be calculated.

For the INSTI® HIV ST usability evaluation, the subjects will be presented with a questionnaire. The overall results of the questionnaire will be used to determine the percentage of subjects who found the INSTI® HIV ST easy to use.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Human Immunodeficiency Virus I Infection Human Immunodeficiency Virus II Infection

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

SINGLE_GROUP

Primary Study Purpose

SCREENING

Blinding Strategy

SINGLE

Caregivers

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Performance

INSTI® HIV ST devices are provided to the enrolled participants to conduct the self test using the provided instruction for use while being observed by an operator. The operator records the INSTI® HIV ST results interpreted by the subjects. The operator then performs the comparator test to compare the results with the INSTI® HIV ST.

Group Type EXPERIMENTAL

INSTI® HIV Self-Test

Intervention Type DEVICE

Each participant will be provided with the INSTI® HIV Self-Test and asked to conduct self testing. The operator will observe the participant and record the subject's interpretation of the results. Subjects will perform the test without intervention from the operator.

The operator will then perform the comparator test and collect a fingerstick blood sample. In the event of a discrepant result between the INSTI® HIV ST and comparator test, an additional venous blood sample will be collected from the subject and sent for discrepancy testing.

Mock results interpretation study and Usability evaluation

A subset of the enrolled subjects (500 subjects) will participate in the mock results interpretation study and usability evaluation. For the mock study, the subjects will be presented with 5 mock INSTI® HIV ST devices with different results, and the subject's interpretation of each device will be recorded. The percentage of subjects who interpreted the mock results correctly for each result type will be calculated.

For the INSTI® HIV ST usability evaluation, the subjects will be presented with a questionnaire. The overall results of the questionnaire will be used to determine the percentage of subjects who found the INSTI® HIV ST easy to use.

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

INSTI® HIV Self-Test

Each participant will be provided with the INSTI® HIV Self-Test and asked to conduct self testing. The operator will observe the participant and record the subject's interpretation of the results. Subjects will perform the test without intervention from the operator.

The operator will then perform the comparator test and collect a fingerstick blood sample. In the event of a discrepant result between the INSTI® HIV ST and comparator test, an additional venous blood sample will be collected from the subject and sent for discrepancy testing.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 18 years of age or older
* Operator/study staff must complete the subject's Enrolment Questionnaire
* Subject to sign and date the Informed Consent Form
* Able to complete the required testing on the allocated testing day(s).
* Able to speak/ read/write English or Spanish
* Willingness to provide the fingerstick blood sample and if necessary, the volume of whole blood collected through venous blood draw (approximately 7 ml)
* Willingness to participate in the study site's standard of care HIV counselling and testing program and receive the study site's standard of care test results
* Unknown HIV Status

Exclusion Criteria

* Has participated in any prior, or concurrent trial of HIV self-tests
* Is a practicing medical healthcare professional (doctor, nurse or HIV Counsellor that performs HIV testing with Rapid Tests)
* Is currently on a PrEP regimen
* Has used a Rapid Diagnostic Test for HIV blood-based self-testing previously
* Has received any experimental HIV vaccine
* Has a bleeding disorder
* Is known HIV+
* Uses Anti-Retroviral medication
* Any condition which, in the opinion of the Operator, would make the participant unsuitable or unsafe for enrolment or could interfere with the completion of the assessment, consent form and questionnaire etc. or bias the outcome, i.e., being unable to see / read by forgetting to bring reading glasses, being intoxicated or acute sickness, or visibly distressed.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

bioLytical Laboratories

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Steven A Geller

Role: PRINCIPAL_INVESTIGATOR

Centennial Medical Group

Anthony LaMarca

Role: PRINCIPAL_INVESTIGATOR

Therafirst Medical Centers Inc.

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Therafirst Medical Center

Fort Lauderdale, Florida, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CLS-003

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.