ENDOPLY System in Humans: a Pilot Study

NCT ID: NCT06292728

Last Updated: 2025-02-25

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

10 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-01-09

Study Completion Date

2025-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Prospective, non-randomized study aimed at defining the initial pattern of gastric plication with the ENDOPLY System, and assess feasibility, ergonomics and safety of the device Prospective, single-centre, open label, consecutive enrolment

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This is a clinical trial of the ENDOPLY System medical device. Clinical data of 10 obese patients (obesity grade I and II) will be analysed. The ENDOPLY System medical device will be used to perform endoscopic internal plication of the stomach. This clinical trial may lead to an extension of the portfolio of medical devices used to perform endoscopic internal gastric plication.

Participation in this clinical trial may help individual trial subjects follow a strict diet that may lead to weight loss. Weight reduction may improve the overall health, quality of life and life expectancy of the trial subjects, but this cannot be guaranteed.

In this clinical trial, the gastric volume reduction procedure using the ENDOPLY System is performed under general anaesthesia. Under general anaesthesia, the ENDOPLY Platform is inserted through the mouth into the oesophagus and upper stomach, after a preliminary endoscopy for standard evaluation. The 5 mm endoscope allows to choose the initial site of the plications, most likely and according to similar techniques at the incisura (junction between the fundus and the antrum). 10 to 15 ligatures will be placed in the upward directions, thereby narrowing the gastric lumen. The investigator will determine during the procedure if the experimented device suits the regular pattern of plication that have been tested over the years in the literature concerning gastric plication.

Gastric volume reduction procedures using the ENDOPLY System may be associated with risks. There is a possibility of rare or unknown side effects. Risks associated with the investigational device (ENDOPLY System) - expected gastric fold fibrosis without adverse local inflammatory reaction. Patients will be administered standard medications as part of the "Standard of Care" endoscopic gastric examination under general anaesthesia.

Subjects participating in this clinical trial will attend regular follow-up appointments at 1, 3, 6, and 12 months after endoscopic internal plication of the stomach as specified in the study protocol.

ENDOPLY System technical information:

The ENDOPLY medical device does not contain as an integral part a medicinal substance or a derivative of human blood or plasma. The ENDOPLY medical device is not manufactured using tissues of animal origin, in order to minimise the risk of transmission of Transmissible Spongiform Encephalopathy to human. The ENDOPLY medical device complies with the essential the requirements laid down for medical devices in conformity assessment under other legislation governing technical requirements for products, with the exception of those aspects which are the subject of clinical trial. Precautions have been taken to protect health and safety with regard to those aspects of the user and the patients. The ENDOPLY medical device does not have a European Union Certificate for now.

Preliminary tests have included preliminary design-freeze and proof of concept, in-vivo studies at the Veterinary school of Lyon in 3 pigs, with an autopsy at three months and pathology samples analysis that have shown the expected fibrosis of gastric folds without adverse local inflammatory reaction.

ENDOPLY System is made by the company ENDOPLY (Lyon, France). The ENDOPLY System has the same goal as the other devices achieving an internal gastric plication, means APOLLO System (means Apollo Endoscopic surgery), ENDOMINA (means comprised of a triangulation platform and an instrument for tissue piercing and approximation) and Medical's Incisionless Operating Platform-primary obesity surgery endoluminal procedure). The ENDOPLY System aims at narrowing the gastric lumen by the mean of separated folds of the internal gastric wall.

The ENDOPLY Platform - Like its competitors, it is an endoscopic tissue approximation device, with the following parts:

* Handle: it is comprised of two parts that are when the jaws need to be closed.
* The system is made of several channels are put together and assembled within a shaft:
* A 5.6 mm channel for the endoscope (paediatric naso-fibroscope), for the time being.
* A 3 mm channel for the endoscopic grasper.
* A 5 mm channel for the ligature holder.
* The ligature: it consists in a 7 cm plastic barbed special tie made in Polyetheretherketone (PEEK), with a self-adjusting mechanism (locker) and fits into a ligature-holder.
* As a secondary step, a box containing reloads will be installed, thus avoiding frequent in-and-out manipulations. The reload will be also automatized, but those upgrades will not be available for the trial.
* The extremity of the platform, including delivery catheters outside of the inner perimeter (that is out of the patient's mouth), has been designed to be ergonomic.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Obesity

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DEVICE_FEASIBILITY

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Treatment

Group Type EXPERIMENTAL

ENDOPLY System

Intervention Type DEVICE

One endoscopic procedure where the ENDOPLY System is used for endoscopic gastric plication.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

ENDOPLY System

One endoscopic procedure where the ENDOPLY System is used for endoscopic gastric plication.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. BMI 30-40, i.e. class I and II obese patients
2. Age above 18 and below 60 years
3. Having failed multiples diet attempts

Exclusion Criteria

1. Achalasia and other oesophageal motility disorders
2. Severe esophagitis
3. Gastroduodenal ulcer
4. Heart disease and hypertension without treatment
5. Pulmonary, renal or hepatic failure, cancer
6. Pregnancy ongoing, scheduled or in the past months
7. Previous bariatric surgery or endoscopic bariatric technique
8. Participation to another study
Minimum Eligible Age

18 Years

Maximum Eligible Age

60 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Just 4 Device s.r.o.

UNKNOWN

Sponsor Role collaborator

ENDOPLY

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Jerome Dargent, MD

Role: STUDY_DIRECTOR

CEO, chief executive

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Fakultní nemocnice u sv. Anny v Brně, Gastroenterologické a hepatologické oddělení

Brno, , Czechia

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Czechia

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Jerome Dargent, MD

Role: CONTACT

0033681472286

Jitka Macháčková, M.Sc.

Role: CONTACT

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Jan Martínek, prof,MD,PhD

Role: primary

Evžen Machytka, MD,PhD

Role: backup

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ENDOPLY1

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Endomina Controlled Study
NCT03255005 COMPLETED NA